When A Septic Tank Air Pump Fails?

If the aerator in your septic system stops working, your system will naturally turn from an aerobic environment to an anaerobic environment, a much slower, much less efficient environment for breaking down the solids in your system.

  • Sometimes your septic air compressor fail can be caused by overheating from too much back pressure on the compressor. The solution here is to replace the diffusers inside the aerobic system in an attempt to get the air flowing into the aerobic chamber again.

How long do septic air pumps last?

How long does a septic aerator usually last? Most septic air compressors will last about three years before a malfunction occurs. Fortunately, spare parts and rebuild kits are available for all of the major aerator brands. These kits can be far more cost effective than purchasing a new aerator.

How do I know if my aerator is working?

You can also disconnect the main hose going to the aerobic tank and feel if the unit is putting out air. If you have an in tank aerator, take off the lid of the aeration chamber and see if the aerator is running. If the aerator is not operating or not putting out air, this is the cause of your alarm.

What does the air pump do in a septic system?

What exactly is a septic tank aerator? An aerator, or air pump, pushes air and oxygen into your septic system. The additional oxygen increases natural bacterial activity within the system, that then provides additional treatment for nutrients in the effluent.

What happens when septic aerator stops working?

If the aerator in your septic system stops working, your system will naturally turn from an aerobic environment to an anaerobic environment, a much slower, much less efficient environment for breaking down the solids in your system.

How often should septic aerator run?

1 Answer. The aerator should run 24/7 nonstop and should not cost more than 10 dollars a month to run. If you electric bill is high something else is causing it or the system is not correctly hooked up.

Should septic aerator run all the time?

The aerator should run 24/7. It should continuously provide much-needed oxygen inside the septic tank of an aerobic system. The aerobic bacteria need air to survive.

How long does an aerator last?

The lifespan of your aerator will vary based on the size of the aerator, the frequency with which it is used, the size of your tank and what elements the aerator is exposed to. Most pumps last anywhere from two to five years before they need to be replaced.

How much power does a septic aerator use?

That’s 86 watts per hour (less than running a 100W light bulb).

How long does it take a septic aerator to work?

Most systems respond rather quickly, say within 4 weeks. The system will be fully functional during this period.

Troubleshooting a Septic Aerator

Septic tanks are made up of a number of different components, with the septic aerator being one of the most important of them. Before water is returned to the environment, septic tanks are used to purify it and make it safe for consumption. septic tanks, in which water is subjected to minimum treatment in order to remove harmful compounds, are connected to the household drainage system (HDS). Aerobic septic treatment, which is assisted by a septic aerator, is the preferred method of treatment for such household septic tanks.

The aeration system is comprised of aerator pumps, which aid in the movement of fresh air into the tank from the outside environment.

Troubleshooting Septic Aerator Pump

The septic aerator pump is made up of several components, each of which must be checked and maintained on a regular basis. Diaphragm The diaphragm is susceptible to becoming excessively dry and worn down over a period of time. You must repair and lubricate the diaphragm in accordance with the instructions in the owner’s manual that was supplied at the time of installation or the retailer’s recommendations. If the diaphragm has significant surface damage, it should be replaced. Standard oils, which may be purchased at hardware stores, are used for lubrication.

  1. The sellers typically provide additional filters that are intended to be replaced every few months.
  2. Cleaning the filters is a time-consuming and a sloppy endeavor.
  3. Diffuser It is not necessary to change the diffuser on a regular basis.
  4. Disconnect the diffuser and soak it in a basin of muriatic acid for a few minutes.

Troubleshooting Lack of Bacteria in Septic Aerator System

It’s possible that your septic aerator system is suffering from a shortage of aerobic microorganisms. This has the potential to reduce the overall effectiveness of the septic tank system. Examining the quantity of sludge in the tank is the quickest approach to figure out what’s wrong with the system. Make sure the aeration chamber is open. Insert a rod into the tank’s inside. If the sludge deposits take up more than half of the rod’s length or more, you will need to discharge the sludge from it.

It is important that no water be used in the house for a couple of hours.

Open the septic aerator tank and rinse away the sludge with a high-pressure garden hose to remove any remaining sludge.

For scrubbing the affected filth, a mop can be used effectively. Using water-soluble, organic additives for dissolving dirt and encouraging bacterial growth might help if some of the deposits appear to be too sticky to remove by hand.

Troubleshooting Septic Aerator through Timely Prevention

If there are any signs of wear on the inside surface of the tank, look into the materials that are being drained into the septic tank system to determine the cause. Inspect the aerator tank to make sure that paint thinners, paints, industrial solvents, and other chemicals are not being routed through it. This protection is also necessary from the standpoint of promoting the growth of germs in the environment. Such compounds have the potential to readily destroy the beneficial microorganisms that are required for decomposition.

Septic Air Pumps – The Lifeline of Your Aerobic System

There are numerous frequent misconceptions concerning the purpose and importance of the air pump or aerator in an aerobic septic system, and these beliefs are addressed below. In this post, I will go into further detail about the significance of your air pump and why it is so critical that it is kept in good working order at all times, including during emergencies.

AEROBIC SYSTEMS VS. CONVENTIONAL SEPTIC SYSTEMS

Aerobic Treatment Systems are a type of wastewater treatment that is technologically sophisticated. They are often composed of a single many chambered tank or a number of tanks with a variety of stages. These stages are often comprised of a solids collection tank (trash tank), an aeration chamber, and a settling tank, among other things. Even more advanced models include an additional four-stage disinfection stage (using chlorine or ultra-violet) that may also serve as a pump chamber. An Aerobic Treatment System is capable of processing waste and discharging water that is more than 98 percent clean and odorless.

Conventional septic systems are typically comprised of a single or two compartment tank that collects big particles while allowing liquids to pass through to a secondary treatment system for further treatment (drain field, mound system, sand filter, etc.).

You’re probably asking what all of this has to do with air pumps now that you’ve gotten a quick introduction of the two primary types of sewage systems.

THE SEPTIC AIR PUMP – IT GOES BY MANY NAMES

On an aerobic system, the air pump can be referred to by a variety of names, among which are the following: Septic Air Pump, Septic Aerator, Aerator Pump, and Compressor are all types of septic equipment. For the purpose of simplicity, I’ll refer to it as a Septic Air Pump throughout this post, and I’ll be referring to the small box in your yard that pumps air into your septic tank rather than any of the other titles I gave above.

THE LIFELINE TO YOUR AEROBIC SYSTEM

In many ways, the septic air pump is the lifeline of your aerobic system. It is impossible for the system to function properly unless the air pump is operating properly. Two distinct functions serve as the basis for the air pump’s operation. Firstly, the air pump introduces oxygen into the water, allowing Aerobic bacteria to colonize and survive in the water. The Aerobic bacteria in the tank are responsible for completely decomposing all of the waste. When compared to the anaerobic bacteria present in a traditional septic system, these bacteria are far bigger and more efficient at digesting waste.

Second, the air pump provides an action in the tank that breaks down big solids into little particles, making it very simple for bacteria to cling to and consume the waste, resulting in a cleaner tank.

It is the absence of a secondary treatment system behind your aerobic system, as is the case with a traditional anaerobic septic system, that poses the greatest risk of this occurring.

Raw sewage dumping into a ditch, lake, or pond, or being sprayed on your grass, as you may be aware, is not a nice thing. For this reason, it is critical for the operation of your system that the air pump is operational.

SIZE DOES MATTER

Another common myth is that because the air pump just adds air to the water, it doesn’t matter what size is utilized. This is not true. It’s impossible to imagine something more far from the truth. The sizing of your air pump is really quite crucial to the performance of your system, and not every system will need the same size air pump as another. If you have visited our website, you are already aware that we provide a wide range of products in a variety of sizes and shapes. It is customary for the size of the air pump to be dictated by the volume of the tank, the kind of air diffusers installed in the tank, and the number of GPD (Gallons Per Day) that the system is meant to treat.

In most circumstances, we just require either the model number of the pump you are replacing or the brand and GPD rating of your aerobic system in order to assist you.

Why Is My Septic Alarm Going Off?

If you are receiving an alert from your septic system, it is clear that something is not quite right. In this Knowledge Base post, we’ll go over the most prevalent reasons of a septic alert, as well as how to identify and avoid them in the future. It is recommended that you contact your local service provider to determine the source of the problem if you are unfamiliar with the operation of your system or do not feel comfortable inspecting it on your own.

ALARMS ON CONVENTIONAL SEPTIC SYSTEMS

Aeration is not present in a normal septic tank since it lacks any form of aeration equipment. If you have this sort of system and you receive an alarm, it is likely that the water level is too high. The following are the primary causes of a high water level in a traditional septic tank system:

  1. Septic tank effluent filter that is blocked with organic matter In many typical septic tank systems, an effluent filter is installed near the tank’s outflow point. Cleaning should be performed on this filter about every 6 months. if the filter becomes clogged with particles, it will slow down the flow of water out of the system, causing the water level in the septic tank to rise
  2. The submersible pump has failed or the float that regulates the submersible pump has failed Even though not all traditional septic tank systems will require a submersible pump, some may do so if they are properly designed. Occasionally, when gravity feeding the secondary treatment system is not possible, an electric submersible pump is employed. The failure of a submersible pump or a float switch will result in a high water level in the pump tank and the septic tank
  3. The outlet line will be stopped, or the leach field will be flooded. An obstruction in the outlet pipe of the septic tank or a failing leach field are the other possible causes of a high water level in the tank if it does not have a submersible pump.

An often-heard myth is that a septic tank alarm signaling a high quantity of sewage signifies that the tank has to be drained out. A high level alert will not signal when a tank requires pumping, and while emptying the tank out may temporarily resolve the warning, once the tank fills back up, the alarm is likely to re-occur due to the fact that the primary problem with the system has not been rectified.

ALARMS ON AEROBIC TREATMENT SYSTEMS

Air pumps and air compressors, as well as internal units such as a shaft aerator or a submersible aerator, are commonly used in aerobic treatment systems. External air pumps and air compressors are also used in aerobic treatment systems. The failure of the aeration device or a high amount of water in the tank are the two most common causes of alarms in aerobic systems, respectively. If your alarm or control panel does not display which alarm is now active, the methods outlined below will assist you in identifying the problem.

  1. To test if the aeration equipment is operational, check the following: If you have an air pump or compressor that is located above ground, be sure that the item is operational before proceeding. You may also check to see if the device is producing air by disconnecting the main line that connects to the aerobic tank. Alternatively, if you have an in-tank aerator, remove the cover from the aeration chamber and check to see whether the aerator is operating. If your aerator is not performing properly or is not releasing air, this is the source of your concern. Depending on the kind and condition of the aerator, it may be necessary to repair or replace the device altogether. Assuming that the aerator appears to be performing correctly, the most likely source of the warning is a high amount of water in the tank. Although this is not an emergency that must be addressed immediately, we recommend that the system be restored to operational status within 1-2 weeks of the incident. Check to check whether the water level in the aeration tank and/or the pump tank is excessively high. In a perfectly functioning system, the water level should be below the intake and at the bottom of the outflow. If the water level is high, the following are the most likely reasons why:
  • If you have a gravity-displacement system, a blockage in the outlet line would be the source of your excessive water level. The chlorine feeder is the most typical source of contamination. Remove the tube that contains the chlorine tablets and clean the feeder of any material that has accumulated. Also, if the system has surface discharges, make certain that the discharge exit is free of weeds and other debris. High water levels in a system with a submersible pump are usually caused by either the failure of the submersible pump or the failure of the float switch, which controls when the pump is turned on and off. The most effective method of testing a float switch is to use an ohm meter to check for continuity. The switch should be tested closed in the elevated position and open in the lowered position to ensure that it is functioning properly. By detaching the submersible pump from the float switch and running it directly from a known functional power supply, the pump may be checked. Remember that the pump will not automatically shut off when you do this, and you will need to separate it from power in order to turn it off before the tank is completely emptied.
See also:  How Often To Pump Out Your Septic Tank? (Solution found)

THIS DID NOT RESOLVE MY ISSUES

If none of the troubleshooting steps listed above appear to resolve the issue you are experiencing, it is possible that there are difficulties with your control panel or alarm system that are causing the system to malfunction or causing you to get a high level alarm.

In this case, we recommend that you contact a professional service provider to inspect the system and address the problem for you.

Common Problems That Occur with Aerobic Septic Systems

6:15 p.m. on June 26, 2019 Use of an aerobic treatment system at Canyon Lake, TX is widespread. Possibly you are in the process of purchasing or relocating to a property that employs an aerobic septic system. In the event that you are unfamiliar with this form of septic system, it is crucial to recognize that they are very different from regular septic systems, and that they come with their own set of possible concerns. As long as you have regular aerobic septic system maintenance performed by an experienced and qualified technician, you will most likely not have any problems with your system.

After all, you can only avoid or correct an issue if you are aware that one exists!

  • Having no power: Do not be alarmed if you realize that your aerobic septic system has just ceased operating. First, make sure that the power switch for your aerobic septic system hasn’t been unintentionally switched off, and that the power breaker hasn’t been tripped by another appliance or person. This is frequently the case, and it is one of the most straightforward difficulties to resolve
  • Problems with submersible pumps: Is your submersible pump not performing as it should be? Investing in a new submersible pump is sometimes the most cost-effective solution to this problem. However, it is possible that the problem is due to faulty wiring or a faulty float, which may be resolved without the need to replace the complete pump. A low level of air pressure in your aerobic septic system: Have you observed that the level of air pressure in your aerobic septic system is lower than it should be? This has the potential to be a significant problem for the operation of your system. However, it may be resolved by purchasing a new aerator or, if feasible, repairing any problems with your present aerator. The timer or photocell is not functioning properly: The timer and photocell are two extremely crucial components of your aerobic septic system, since they are responsible for retaining the water in the pump tank until it is time to release it into the environment. In the event that this portion of your system isn’t functioning properly, it is possible that one of these components is malfunctioning. A problem with your spray head might be caused by it not rotating properly or not popping down after spraying once it has finished. Unfortunately, a professional will be able to repair or replace this component with relative ease. Failure to perform routine maintenance: In the event that you fail to get your aerobic septic system maintained on a regular basis by a skilled and licensed expert, the likelihood that one of the problems outlined above will occur increases significantly. Stick to a regular maintenance plan and delegate the work to an experienced professional to avoid this destiny
  • Or

Do you have a nagging feeling that something is amiss with your septic system but aren’t sure what it may be? We are here to assist you! Make a call to Countryside Construction Inc., and we will dispatch a team to assist you with your aerobic treatment system in Canyon Lake, TX. Contact us now. We look forward to being of service to you in the near future! Septic Services,Aerobic Treatment Systems,Aerobic Treatment Systems Admin is the author of this blog article.

Aerobic Septic Problems

Before a manufacturer of a certain OSSF model may sell their model in Texas, the model is submitted to a testing center for a six-month routine of rigorous testing. If the tank fractures while being tested, the test will be deemed a failure. The manufacturer had to pay $250,000 for each tank that was subjected to these tests. This case study is about an OSSF that had multiple fractured walls, as described in the introduction. Advanced Aerobic Systems was selected to offer maintenance services for an installed OSSF that was positioned near to a water source.

  1. The tank has been in use for three years.
  2. Advanced Aerobic Systems discovered major breaches in the common internal tank wall that the pump tank shares with three other compartments after doing a more thorough inspection (trash, treatment and clarifier -see tank diagram).
  3. Because of several fractures in the common wall dividing the garbage, treatment, and clarifier compartments, effluent from the trash, treatment, and clarifier compartments flowed into the pump tank section.
  4. An in-depth examination was done and delivered to the property owner, along with many photographs of the tank and its contents.
  5. In order to get a second opinion from the original installer, the owner contacted the company.
  6. According to the county, either the owner or the installer would be required to demonstrate that coliform bacteria (a disease indicator) was being pushed into the spray field.
  7. Although this technique is not necessary in this county, it was not included in the maintenance contract because it is not required in this county.

Other counties would demand either the tank be successfully repaired or replaced based on the prima facie evidence of fractured walls and uniformly low water levels, according to the prima facie evidence.

What Happens When Your Septic Aerator Alarm Goes Off? – B&B Pumping – Top Rated Septic Cleaning Services

There are a variety of reasons why the alarm goes off. Even if the problem is minor, the alarm will ring to make sure that you fix it as soon as possible when it occurs. A problem with the timer, on the other hand, is one of the most common causes for an alarm to go off in the first place. Several aerator alarms are equipped with some form of timing device. In order to keep the drain field from overflowing during periods of excessive water demand, the timing must be set appropriately. These timer systems are in charge of cycling the septic tank through a series of cycles to guarantee that it does not overdose the drain field with sewage.

  1. In this instance, the water levels will rise until the timer is able to engage the pump once more.
  2. There are a variety of reasons why this procedure may cause the alarm to sound.
  3. Additionally, if there is groundwater infiltration into the septic tank system, the alert may ring.
  4. In addition to these being the most common causes of alarms, we’ve discovered that a failure inside one of the tank’s components can also result in an alert being activated.
  • It is possible that the chlorinator is blocked. There is an issue with the alarm’s wiring
  • It needs to be repaired. The diffuser has become blocked. The float switch is not working properly
  • The aerator is not operational or has insufficient air pressure

Septic Air Compressor Fail? – Affordable Solutions

Failures of septic air compressors can be quite expensive. If the region has been ignored for a long period of time, it is possible that the elements have forced a complete replacement. It is possible that the internal failsafe to the motor is the cause of the septic air compressor failure signal sounding in many cases; however, this is not always the case. A few remedies, as well as some preventative maintenance, are discussed below in relation to your septic water pump. Allow us to assist you in maintaining the full functionality of your septic system.

Septic Air Compressor Fail?Call Us Today!

Depending on the type of compressor installed in your septic system, you may find yourself in a scenario where the internal vanes or diaphragms have failed completely. When this occurs, certain compressors may continue to operate even if they are not generating any air at all. Inspect and test the operation of your air pump, paying close attention to the amount of air bubbling in the aerobic tank or detaching the little air tubing from the air alarm. As previously said, be certain that air is flowing since if the compressor is not pumping air, it will overheat and burn out the motor.

Repair kits for your aerobic septic system can save you hundreds of dollars over the cost of a new air pump if you do regular preventive maintenance.

Aerobic System Air Leak

If you hear ‘hissing’ and/or no ‘bubbling’ coming from the aerobic tank, it is likely that you have an air leak, which is the cause of the septic air compressor failure warning to occur. Air leaks are most often straightforward PVC repairs, however the amount of digging required varies from system to system depending on how the system was placed and where the break in the line is situated. If you suspect you have an air leak, act promptly to rectify the situation as soon as possible. Because it is just as destructive to the entire system as having a non-operational septic compressor is to the individual septic tank.

Clogged Air Diffusers

When your septic air compressor fails, it may be due to overheating as a result of excessive back pressure on the compressor. The remedy in this case is to replace the diffusers inside the aerobic system in an attempt to re-establish air flow into the aerobic chamber. Allowing a professional installer to do this type of repair is highly recommended due to the fact that the diffusers inside practically every brand of system are positioned differently or may even be in a completely different place.

Aerobic Compressor -Preventative Maintenance

  • Spread ant poison in the immediate area
  • Clean or replace the air compressor filter
  • Remove any overgrowth from the immediate area

CAUTION: WHEN WORKING IN THE AREA OF ELECTRICAL EQUIPMENT, BE SAFE AND REMOVE THE POWER TO YOUR SEPTIC FROM THE OUTLET. However, the most essential thing to remember is that you should spread ant poison around the immediate region of your sewage system’s air compressor. To fully cover the base of your air compressor if it has a housing, you will need to obtain the appropriate screwdriver or bit to remove it so that you can properly cover the base with poison. While you have the lid off, take the opportunity to inspect and clean the compressor’s filter, if any debris is present.

  • Additionally, remove any overgrowth of bordering plants from the local area.
  • We propose just cleaning the area surrounding the housing of any grass or weeds and spraying it with weed killer to avoid any further development in the region in the future.
  • Please contact us to learn more about the many services we can give to assist you with the upkeep of your compressor.
  • We make it our mission to diagnose and repair your septic system, as well as educate you on how to extend the life of your system via preventative maintenance.
  • For additional information on typical septic system problems, please see our Septic System Repair Page.

Alternatively, you may arrange a free consultation online right now! Please do not hesitate to contact us if you have any questions or concerns about your septic system. We are happy to assist you.

Call Us Today(832) 960-1679

The procedure is not hindered by high temperatures at any point during the process. The aerator is equipped with a fan to keep it cool even in high temperatures. Aeration systems for septic systems are being erected all throughout North America, from Arizona to Alaska and Canada, where temperatures can drop below -40 degrees Fahrenheit and there is feet of snow cover during the winter. Our septic aeration systems are not adversely affected by these harsh weather conditions.

See also:  How Do I Find My Septic Tank Layou? (Best solution)

Do I need any special tools to install one of your Septic Aeration Systems?

To do this project, you will need a garden shovel, a 5/8-inch drill bit and drill motor, and a small bottle of silicone caulk, assuming you have an outside outlet (power source).

I hear a gurgling sound when I flush the toilet

When this happens, it indicates that the pipes are not draining correctly. A blockage in the pipe might occur either before or after the septic tank is installed. Remove the septic tank cover and check to see if the level in the tank is greater than the level in the baffle. If it is, the blockage is located there. The blockage might be anywhere between the home and the septic tank if this is not the case. A mature biomat that has to be removed using the Septic System Saver® aerator is most likely present if your septic tank level is high.

Will I have to touch or come in contact with sewage when I install one of your septic aeration systems?

In most cases, if the septic aerator is properly placed, you should not come into touch with any waste water. When you remove the clean out lid from the septic tank, you will notice a strong stench of septic waste.

Do I need to pump the tank before installing one of your septic aeration systems?

If you decide to place the product in your septic tank, we recommend that you pump the tank prior to installing the device.

Do I need to pump the tank out while one of your septic aeration systems is working?

You should not have to pump the septic tank any more frequently than you did before the septic aerator was installed in the tank. After around 30 percent of total tank content has been reached by solids, we recommend that you pump out your septic tank and replace it with new solids.

My septic pumper told me that I have a problem with septic water running back from my drain field. What does he mean?

It’s possible that he’s referring to two separate concerns. The vent pipe should be terminated at a height of at least 12 inches above the ground. Rainwater will not be able to enter the septic system through the vent system as a result of this. According to him, the other problem was that when pumping the septic tank, he noticed effluent leaking backward into the septic system from the drain field. A saturated drain field means that the septic effluent cannot be disbursed as quickly as it is received by the septic system, and this indicates that the drain field has become clogged.

This problem will be resolved by our septic aerator.

How do I know if my septic system is failing because of a clogged biomat?

The biomat in the great majority of septic systems becomes blocked, resulting in the system failing. Hire a pumper to inspect your system and establish whether any effluent is returning to the septic tank while the system is being pumped. Instruct them to estimate the amount of effluent that returned to the tank.

If it is a tiny quantity, it is possible that a clogged pipe exists between the tank and the field. If there is a significant amount, there is a good possibility that the biomat is clogged. You absolutely have nothing to lose by checking out the Sewage System Saver® septic aeration system!

How do I know if my septic system is failing?

A blocked biomat is responsible for the great majority of septic system failures. Hire a pumper to inspect your system and ascertain whether any effluent is returning to the septic tank while the system is being inspected. Instruct them to estimate how much effluent returned to the tank after it was flushed out. The tank and field might both be choked with sediment because of the tiny quantity of water present in them. If there is a significant amount, there is a good possibility that the biomat has become obstructed.

I have a septic odor in my back yard. Will your septic aerator fix this?

Yes, the Septic System Saver® aerator will completely eradicate the stink from the system. The presence of a septic odor in your yard indicates that wastewater has either reached the surface or is very close to the surface. A walk around the region of your yard where the septic system is installed is recommended. Look for spots where the grass is more lush or greener than the rest of the lawn. If you come across an area like this, the most likely reason for it is the establishment of a clogged biomat.

Can I speed up the process?

In order to accelerate the restoration process, water consumption must be reduced, as well as the use of chemicals that are flushed down the toilet. Unless your behaviors are very harmful, you should not be required to change them! Simple actions like turning off the water while brushing your teeth, keeping a container of drinking water in the refrigerator, and spacing out laundry loads, among other things, should be done to ensure that your water fixtures are not leaking before they become a problem.

My septic pumper tells me I need to install a new field

Others have told us that local septic system suppliers have informed them that the only answer is to rebuild their drainage field. We have received several reports like this. Many tens of thousands of dollars are required to implement this solution. There is also the possibility that your whole drainage system may be condemned during the permission procedure for a new drainage bed and will have to be replaced with extremely expensive systems such as a mound system or a holding tank. This isn’t the case at all.

Will the Septic System Saver® septic aeration system work on all septic system types?

Using the Septic System Saver®, you may aerate any form of septic system, including conventional drain fields, mound drain fields, trenches drain fields, chambers drain fields, gravel and pipe drain fields, weeping beds, sand filters, drywells, seepage pit septic systems, and cesspools and lagoons.

Septic Services Gazette

Septic Services news and information is available from this site. You’ll also discover articles that are both informative and useful, as well as ideas and suggestions for those who own septic systems. Aerators are used in aerobic septic systems in a variety of configurations. An aerator with a shaft is one kind that has been in use for many years due to its durability and effectiveness. Generally, if you maintain your shaft-style aerator properly, it will last for many years.

However, if you believe that your aerator is not functioning properly, here are some aerator troubleshooting ideas that you can use to guarantee that your aerator is functioning properly. Symptom: The aerator has ceased working.

Problem Solution
Tripped mini-breaker Check for high water level in tank.Clean debris from shaft, make repairs, and reset breaker
Timer set to “off” position Set timer to “on” position
Tripped house panel breaker Call qualified electrictian
Worn out aerator Replace aerator

Symptom: The aerator is drawing an excessive amount of current.

Problem Solution
Suds restrictor submerged in water determine cause of high water level, make repairs
Debris on aerator shaft Clean debris from aerator shaft
Worn out motor Replace aerator

Sympton: The aerator is creating a lot of noise.

Problem Solution
Worn out bearings Replace bearings or aerator
Vibration* Bent shaft or shaft out of balance* Suds restrictor at water level* Loose aerator brackets (in riser) * Straighten or replace shaft* Determine cause of high water level* Re-adjust brackets
Aerator not level in riser Re-position aerator

What do I do if My Septic Alarm is Going Off?

In the event that your septic alarm goes off, it may surely create some anxiety and uncertainty; and if you happen to be experiencing this right now, then you’ve arrived to the correct location! Don’t be concerned; it does not necessitate urgent action. Instead, take your time to go through this full essay so that you will be prepared to act now or in the future if the situation arises. What Septic Systems Are and How They Work The alarm works in conjunction with the septic system to alert you when the water level within the pump tank has increased to an unsafe level or has decreased to an unsafe level.

  • The timer is in charge of regulating the time intervals during which the pump is permitted to pump wastewater into the drainage system.
  • Thus, during periods of excessive water use, the drain field is kept from getting overflowing, which might cause damage to the drainage system.
  • A large amount of water is injected into the system in between pumping cycles for whatever cause, and the water has nowhere else to go but back into the system’s pump tank.
  • Depending on how much water was and continues to be put into the system and how the pump is set up to operate on a timer, it may take many pumping cycles until the water levels are returned to normal.
  1. If you’ve ever had your septic alarm go off, you know how much stress and uncertainty it can create. If you’re now experiencing this, you’ve come to the perfect spot! Don’t be concerned
  2. It does not necessitate urgent action. Instead, take your time to go through this full essay so that you will be prepared to act now or in the future if the situation warrants. What Septic Systems Are and How They Function In conjunction with the septic system, this alarm is designed to alert you when the water level within the pump tank has increased over a certain level or decreased below a certain level. All septic systems with pumps are required to have some type of timer installed. Using a timer, you may control how much wastewater the pump is permitted to pump into the drain field at different times of day. At certain periods of the day, these precise time intervals will occur. Thus, during periods of excessive water use, the drain field is prevented from getting flooded, which might cause damage to the drainage system. How Does a Problem Occur When There Is One? A large amount of water is brought into the system in between pumping cycles for whatever cause, and the water has nowhere else to go but back into the system’s storage tank. As a result, the water level within the pump tank will rise until the timer enables the pump to be turned back on. It may take many pumping cycles until the water level in the system returns to normal levels, depending on how much water was and continues to be injected into the system during the time intervals specified by the timer. Causes of the alarm going off that might occur
  1. Somehow, groundwater is making its way into the system. If there is an excessive amount of standing water surrounding the septic tanks, whether generated by rain or another source, the water may seep into the tanks and cause the internal water level to rise.
  1. It’s possible that one of the components of the septic system is malfunctioning. If anything goes wrong with your system — including the pump and floats — the alarm and timer will go off and the septic system will stop working correctly.

The Best Thing to Do If Your Alarm Goes Off Alternatively, if you hear an alert, you should press the red button or turn on the alarm box. The alarm will be turned off as a result of this action. There should be a red light and a green light on the alarm box, which should be situated someplace on the unit. The green light indicates that the alarm is operational and should be left on at all times. It is shown by a red light if the alarm is getting a signal from the pump tank indicating that the water level is increasing above or decreasing below what is expected.

  1. If the breaker occurs to be tripped, look around the septic tanks to see if there is any standing water.
  2. It is possible that the red light on the alarm box will go out on its own after allowing the septic system to operate for a couple of pump cycles (which should take approximately 10-15 hours).
  3. If the red light turns off, it signifies that the system is operating properly and that it only needs to catch up with the extra water that has overflowed into the storage tank.
  4. To be clear, an alarm signal from the septic system does not always imply that sewage is about to back up into the house right away.
  5. Do you require septic system repair on a regular basis or emergency service?

To arrange an appointment, please call (804) 581-0001 or send us an email through our contact page. Want to learn more about septic systems? Explore our septic system web sites by clicking on the “Septic” navigation option in the top navigation bar.

Troubleshooting Pumps: The Pump Motor Doesn’t Run

Check the wires in the septic system for damage with a voltmeter or comparable gadget to determine whether or not they need to be replaced.

See also:  What To Do About A Septic Tank Leak? (Best solution)

Interested in Pumps?

Get the latest Pumps articles, news, and videos delivered directly to your email! Now is the time to sign up. Pumps+ Receive Notifications Checking for faults with a septic pump’s electrical system, the pump itself, and its controls are all important first steps when it won’t start. Dealing with electricity may be extremely dangerous; thus, exercise extreme caution while working with electricity and turn off power supply breakers when testing components inside the electrical system. If you are not 100 percent sure in your ability to execute any of these tests safely, consult with a specialist before proceeding.

Electrical problems

If the pump does not appear to be operating at all, does not respond to any testing, and does not appear to be pumping effluent, it is possible that there is a wiring issue. Examine your circuit breaker first, and then try to use a voltmeter or similar equipment to check the wires in your septic system for damage to determine whether or not they need to be changed. If the wires are damaged, replace them.

  1. A fuse has blown or a circuit breaker has been triggered on the circuit. Check the fuses and circuit breakers. Fuse replacement is necessary as needed. Take note of the pump manufacturer’s suggested size as well as the pump nameplate rating. In the event that a circuit repair is required, contact an electrician. The power cord for the pump is improperly connected and makes poor contact with the pump. The pump cable cap prongs should be checked for tightness and corrosion if the system is equipped with a piggyback plug in. Alternatively, replace the plug, clean the plug prongs with abrasive paper, or have the electrical receptacle changed
  2. The branch circuit wiring is insufficient to support the pump load. Check the voltage on the line and compare it to the manufacturer’s standards if necessary. The pump should be hooked into a separate circuit breaker from the rest of the system (or fuse). If the circuit breaker also supplies electricity to other outlets or appliances, an additional outlet should be added so that the pump has its own circuit breaker as well. The pump motor overload tripped the circuit, which necessitated the call for an electrician. Allow the pump to cool for five to ten minutes before reconnecting it to the power source. If the overloadtrip occurs again, remedial action should be taken. Verify that the line voltage is within specifications by comparing it to the manufacturer’s specs. Check the voltage of the branch circuit with an electrician or with the power provider. Make sure that the pump is connected to a separate branch circuit since the voltage provided is insufficient. Voltagenmust be within 10% of motor ratings on either side of the equation. Check that adequate power is being sent through the system by measuring the voltage at the pressure switch, the control box, and any other components through which power is being delivered. a. If you notice that the electricity is too high or too low at the power panel, you may need to call the electric utility provider for assistance. Thermal overload and shutdown will occur as a result of low voltage at the pump. Call your local electrician to fix the circuit and, if necessary, contact your energy supplier. Check the controlpanel connections and watertightness as well. Look for clear evidence of flaws and wear on the control panel with a visual inspection. Check for faulty connections as well as burned or melted components. Perhaps your prior examination of the power supply at your control panel led you to the conclusion that a bad splice connection or broken conduit could be the source of your problem. Make a visual inspection of any electrical splice connections for corrosion and other visible evidence that power is not being delivered to the pump. It is important to ensure that the conduit, and thus the wire within it, has not been damaged (for example, if it has been struck by a lawn mower).

Pump problems

It is possible that the motor for the lift pump is not functioning properly, in which case power is still flowing to the pump but it is unable to function. At this stage, make sure that the pump is not clogged and that it is capable of performing its intended function; otherwise, the pump will need to be fixed or replaced totally.

  1. Theimpeller has been blocked or restricted. Disconnect the power, remove the pump from the sump, and inspect it for freedom of rotation of the impeller and shaft. Clean the volute and impeller, and remove any obstructions
  2. The bearings have frozen in their positions. Disconnect the power, remove the pump from the sump, and inspect it for freedom of rotation of the impeller and shaft. Lower bearing of the column pump should be free and lubricated. In order to repair the pump bearing, contact a licensed service shop. The water level is not sufficiently enough to activate the control switch. Water should be added to the sump to make it turn on. Control floats or weights must be readjusted
  3. An internal motor problem exists. Pump should be removed, power should be disconnected, and rated voltage should be connected before the controlswitch is actuated. To have your vehicle repaired or replaced, contact an authorized service shop.

Float/control problems

In comparison to a float tree, a pump linked to a line is used. If the pump detects sewage levels using a float, the float may become caught or destroyed, in which case the pump will not operate. Usually, you can adjust the float or otherwise correct it so that it floats normally again, but if the problem is severe enough, you may need to replace the float totally.

  1. The operation of the float is hampered or restricted in some way. Water should be added to the sump to make it turn on. Make any necessary adjustments to the control floats or weights. If the float rod is bent or obstructed by debris, consider adding a separate float tree to make pump removal and float operation easier. If the float rod is bent or obstructed by debris, consider replacing it. Examine and keep an eye on things. Make necessary adjustments to the control floats or weights
  2. The float switch is faulty. Remove the pump, turn off the power, connect the power to the rated voltage, and turn on the controlswitch. Inspect for deformation, charred or melted components, or a significant amount of black discoloration. Unplug the pump’s chord from the piggyback plug on the floatswitch, and then reconnect the cord. To test the pump, just put the plug straight into an electrical outlet. If the pump continues to run, the float switch has failed and must be replaced. (Do not keep the pump plugged in for an extended period of time or it may burn out.) Make any necessary adjustments to the control floats or weights. Replace the liquid level control with a new one. Give the pressure switch a thorough visual inspection to check for flaws and wear and tear. Turning on and off switches is essential for a fully functioning system, and they are reasonably priced.

a little about the author Sara Heger, Ph.D., is an engineer, researcher, and lecturer in the Onsite Sewage Treatment Program at the University of Minnesota’s Water Resources Center. She holds a bachelor’s degree in civil engineering and a master’s degree in environmental science. She has given presentations at several local and national training events on topics such as the design, installation, and administration of septic systems, as well as research in the related field. Her responsibilities include serving as the education chair for the Minnesota Onsite Wastewater Association and the National Onsite Wastewater Recycling Association, as well as serving on the National Science Foundation’s International Committee on Wastewater Treatment Systems.

Heger will respond as soon as possible.

This article is part of a series on troubleshooting pumps:

  • If the pump motor does not turn on, troubleshooting is necessary. Pump problems include: the pump turns on, but there is no water
  • The pump turns on, but there is no water. Pump problems include the following: the pump runs continuously or cycles too frequently
  • Pump problems include the following: the pump makes a lot of noise
  • Pump Troubleshooting: There is a strong odor of sewer gas

3 Tips to Keep Your Aerobic Septic System Strong

1. Keep your aerator in good condition. The advantages of an aerobic septic system are derived from the microorganisms that are utilized to break down waste. A typical system comprises anaerobic bacteria, which can live in the oxygen-depleted environment of a septic tank and treat the waste produced. Aerobic septic systems include aerobic bacteria, which are microorganisms that require a constant supply of oxygen in order to function properly. The aerator, which is a component of an aerobic septic system, is responsible for supplying this oxygen.

  1. If the aerator stops working, the bacteria will not be able to acquire enough oxygen to survive.
  2. Aerators die for a variety of reasons, the most prevalent of which are as follows: The first problem is caused by blocked air diffusers.
  3. Furthermore, the blockage causes a significant amount of pressure within the aerator itself.
  4. The second most prevalent reason of a failing aerator is insect infestations.
  5. Eventually, when the nest has grown sufficiently, it will induce a short, which will render the aerator non-functional.
  6. Secondly, never use chlorinated pool waterAerobic septic systems are distinguished by the presence of a unique component known as the chlorinator, which disinfects waste water before it is discharged into your yard.
  7. On a semi-regular basis, it is necessary to replace the chlorine in the chlorinator with fresh chlorine.

These pills are quite similar to ones that are commonly seen in swimming pools.

Trichlorisocyanuric acid is included in the tablets used to treat swimming pools.

Swimming pool pills do not dissolve rapidly enough, nor do they have the chemical strength required to disinfect septic system waste water.

3.

Two tanks are used in an aerobic septic system.

Aerobic bacteria break down solid waste into sludge in this environment.

The liquid is pumped from the pump tank to the chlorinator, where it is discharged onto your grass.

However, a system that is ill or poorly managed may not be able to break down liquid waste to the extent that it should.

Clarity testing may be performed by a specialist to assess how clean the water in your pump tank is and how well your system is functioning.

More information on having a clarity test conducted on your aerobic system may be obtained by contacting Walters Environmental Services, a leading septic service provider.

Septic system failed – should I try installing an aeration unit?

In the previous couple of weeks, I’ve made significant strides forward in my circumstance. My leach field was around 95 percent obstructed, with very little, if any, movement in the water. I had already moved the graywater to another solution, which had been beneficial for a time, but the field began to fail gradually, eventually failing to the point of being virtually unusable. I have a single septic tank and wanted to experiment with aeration without incurring the expense of a second tank. I discovered a number of things that I haven’t seen openly stated on any of the boards, so I wanted to share them here in the hopes that it would be of use to someone else.

Too much air volume was introduced into the tank, and it was placed in the middle of the tank, causing excessive churning and sediments to escape the tank.

I was under the impression that it didn’t work for a number of months.

However, in the last couple of weeks, I’ve noticed that the water levels have really dropped to the point that they are STAYING at the edge of the output pipe!

I utilized the approaches outlined below to prevent having to replace my field without spending $1000 on a solution.

They must pass through the first baffle and separate in order for the lighter stuff to ascend and the heavier materials to descend through.

If you look about, you can find diaphragm diffusers for as little as $35 that can be attached to PVC pipe and activated by an air valve that supplies JUST ENOUGH air pressure/volume to activate the diaphragm (this is an air RELIEF valve, not a cutoff valve).

If you use too much, you’ll get a torrential downpour (which you don’t want).

Everything may happen away from where the tank is settling, which saves time and energy.

In addition, I received a 4 “On the output side, there was a TEE that acted as a divider.

You don’t want bubbles to rise into the TEE, since this might cause some debris to be drawn into the TEE.

When it comes to my solitary concrete tank, one idea I had from a local contractor was to empty it, climb inside, and create a cinderblock wall that would allow for two-thirds incoming/settling and one-third aeration.

There is a requirement for several hundred gallons of aeration space.

If you can find a method to open the other end of your leach lines in order to expand your field, even temporarily, you will be able to move this newly invigorated aerated bacteria through there more quickly, allowing it to begin to work sooner.

It is important to note that I did not need to purchase super duper amplified bacteria to add.

That’s analogous to purchasing weed seeds: if you give dirt enough rain, the weeds will appear.

My findings show that the low agitation treatments available for $500-$1000 that are already on the market would almost likely work. I just choose to experiment with a do-it-yourself option. I hope this is of use to someone.