What Are The Dimension Of A 1000 Gal Septic Tank? (Question)

Our 1000 gallon septic tank, made with precast concrete, is designed to hold 1000 gallons of liquid.

1,000 Gallon Concrete Septic Tank Overview.

1000 Gallon Septic Tank Dimensions Details
Tank dimensions 8′ x 5’8” x 5’2”

16

What is the dimensions of a septic system?

A typical residential septic tank is usually about 4.5 feet wide x 8.0 feet long x 6 feet tall.

Is a 1000 gallon septic tank big?

The larger your home, the larger the septic tank you’re going to need. For instance, a house smaller than 1,500 square feet usually requires a 750 to 1,000-gallon tank. On the other hand, a bigger home of approximately 2,500 square feet will need a bigger tank, more than the 1,000-gallon range.

How often do you pump a 1000 gallon septic tank?

But here are some general guidelines: Family of 2, 500-gallon tank – pump every 2.5 years. Family of 3, 1000-gallon tank – pump every 4 years. Family of 5, 1000-gallon tank – pump every 2 years.

What should be the size of septic tank?

Length of septic tank (L) should be taken as 9feet 9 inches or 9.75 feet. Breadth of septic tank (B) should be taken as 6 feet 3 inches or 6.25 feet. The standard height (D) of septic tank should be taken as 5 feet 9 inches or 5.75 feet.

How do I calculate the size of my septic drain field?

Drainfield Size

  1. The size of the drainfield is based on the number of bedrooms and soil characteristics, and is given as square feet.
  2. For example, the minimum required for a three bedroom house with a mid range percolation rate of 25 minutes per inch is 750 square feet.

What is the average size of a home septic tank?

Common residential septic tanks range in size from 750 gallons to 1,250 gallons. A septic tank is a self-contained unit designed to hold residential wastewater. The system is comprised of two main components: the tank and the drain, or soil absorption field.

What Are The Dimensions Of 1000 Gallon Septic Tank?

Disclosure: This post contains affiliate links, which means that if you purchase a product after clicking on one of our links, we may receive a commission or free product from the firms featured in this post. Amazon is a good illustration of this. Knowing the physical dimensions of a septic tank, which is designed to store a capacity of 1000 gallons of wastewater, is important for a variety of reasons. When a septic tank is in need of repair or cleaning by specialists, it is critical to know the size of the tank in question.

So, what are the measurements of a 1000-gallon septic tank?

The dimensions of a low-profile tank are 120″ L x 67″ W x 57″ H.

To learn why an aseptic tank should not be too deep or too shallow, continue reading this article.

Dimensions of a septic tank

CALL 1.855.925.0760 FOR A LOCAL SEPTIC QUOTE

If you are considering having a septic tank placed, you should be aware of the many types of tanks that are often utilized in residential settings. These are the ones:

  • Concrete tanks, plastic or polyethylene tanks, fiberglass tanks, and other types of tanks are available.

A septic tank with a capacity of 1000 gallons may have modest differences in size based on the kind of tank being installed (whether it is a fiberglass tank, plastic tank or concrete tank). As a result, it is necessary to have a basic awareness of the kind of septic tank in order to comprehend the dimension elements involved.

CALL 1.855.925.0760 FOR A LOCAL SEPTIC PUMPING QUOTE

There are a lot of elements that influence the size of any septic system that you may require in your home. The system’s dimensions are determined by the size or capacity of the tank, as well as the type of tank used in it (as mentioned above). Consequently, the size of a septic tank is determined by the square footage of the land. It is dependent on the number of bedrooms in the house as well as the overall number of people that live in the residence. Here are some statistics about the size and dimensions of a septic tank to help you understand them better:

Type of Tank Tank Capacity Tank Length (inches) Tank Width(inches) Tank Height(inches)
Concrete Septic Tank 1000 Gallon – Heavy Duty 96 78 61
1000 Gallon – Low Profile 120 67 57
Plastic or Fibreglass Septic Tank 1050 Gallon 126 60 51
Steel Septic Tank 1000 Gallon 58 58 96

Understanding Septic Tank Sizes

A septic tank on any property is the initial point of contact for wastewater that is discharged from a dwelling. This effluent then remains in the septic tank for an extended period of time. Several processes are taking on inside the tank during this time period, which are detailed below. Solids are separated from liquids during this step of the process. Once this is completed, the particulates are filtered out and the remaining water is allowed to run away through the drainage field.

The size or dimensions of the septic tank, on the other hand, are critical in order for all of this to occur properly. When specialists build a septic tank, they take into consideration a number of critical factors. Among these considerations are:

  • The total number of square feet of the property
  • There are several bedrooms in the house. There will be a certain number of individuals that will use the property. The frequency with which guests arrive
  • The frequency with which major meetings, parties, or get-togethers are held

When homeowners seek the assistance of professionals, things become much simpler. When installing a septic tank, professionals take into account all factors and guarantee that the tank is the appropriate size and proportions. It should also be mentioned that if there are additional users, the capacity of the tank should be increased by 180 litres for each extra user.

In Case the Septic Tank is Smaller – What Happens?

The tank’s dimensions are determined by the size of the tank. Multiple issues will develop if the septic tank is too small and insufficient in capacity. Because of the volume of wastewater that will be generated on the site, it will be unable to cope. The possibility of all kinds of unpleasant situations arises if the septic tank is smaller than the appropriate size. This can manifest itself in a variety of ways, including offensive and stinky odors, overflowing tanks, and obstructions. The most serious issue that might develop as a result of a tiny tank’s capacity is that the resulting pressure can cause liquids to escape before they have had a chance to be completely filtered out.

As a result, they will continue to accumulate in the septic tank.

CALL 1.855.925.0760 FOR A LOCAL SEPTIC QUOTE

In the same way that a septic tank that is too small can cause multiple difficulties, a septic tank that is too huge can cause several problems. A tank that is too large will not perform properly. The effluent will not be able to pass through it efficiently. For example, if you have an overly big septic tank, there may not be enough liquid accumulation, which might lead to an excessive buildup of germs. Because the processing will not take place organically if this occurs, the solids in the tank will not break down adequately as a result of this.

This will ensure that everyone’s health and full hygiene are protected.

Considering the Features of Your House to Determine the Septic Tank SizeDimensions

The requirements of the family must be taken into consideration first and foremost when a homeowner considers the construction of a septic tank. There are various aspects of a home that must be considered while designing it. When purchasing a home, keep the following in mind:

  • More than one dishwasher
  • More than one kitchen
  • More than one bathroom
  • Showers with waterfalls
  • Low-flow devices
  • A hot tub, a swimming pool, and an indoor spa are available.

All of these items are regarded to be nice elements in any home and should be included. In addition, because of the increased water flow, these luxury features will raise the demand for a septic tank with a greater specified size because of the increased water flow. Because of the increased demand for water, it is possible that the tank may need to be larger.

CALL 1.855.925.0760 FOR A LOCAL SEPTIC QUOTE

  • Approximately how many bedrooms can be supported by a 1000-gallon septic tank

A 1000-gallon septic tank has the capacity to support a three-bedroom house. The property should have a maximum square footage of 2500 square feet. For further information, please see this page. No, you should never drive over a septic tank with a capacity of 1000 gallons.

In the event that you drive over the tank, damage to the pipes and leach field will occur. If the damage is extensive, the septic tank will malfunction, resulting in costly repairs to the system.

  • The frequency at which you should pump a 1000-gallon septic tank

The average septic tank holds 1000 gallons and may be pumped once every five years if it is utilized by two persons. If, on the other hand, the same tank is utilized by eight people, it should be pumped out once a year. More information about septic tank pumping may be found by clicking here.

  • The average septic tank holds 1000 gallons and may be pumped once every five years if it is only used by two people. A year’s worth of pumping should be performed on a tank that is shared by 8 persons. Septic tank pumping is discussed in further detail here.

It will require two lids due to the size of the container. When cleaning or pumping the tank, two lids will provide you simple access to the whole tank. Depending on where you live, a 1000-gallon septic tank might cost between $800 and $900. It is dependent on your geographical area as well as the contractor you hire. Your local contractor will be able to give you an accurate estimate of the cost.

  • In order to pump a 1000-gallon septic tank, how much will I have to pay?

In order to pump a tank with such a capacity, a user may be required to spend anywhere between $225 and $400, depending on the circumstances. More information about septic tank pumping expenses may be found here. The usefulness and functionality of a septic tank are greatly influenced by the size of the tank. As a result, only professionals can assess the size of a septic tank after taking into account a variety of elements. More information may be found at:1000 Gallon Septic Tank Owners Guide.

CALL 1.855.925.0760 FOR A LOCAL SEPTICQUOTE

Table of ConcreteSeptic TankOutsideDimensions,Capacity,Other Data
Rectangular ConcreteSeptic Tank Size(Gallons Capacity) Tank Length(Inches) Tank Width(Inches)
1000heavy duty 96 78
1000low profile 120 67
1000/600 145 in. 68 in.

SEPTIC TANK WITH 1000 GALLON CAPACITY102″ LENGTH69″ WIDTH59″ HEIGHT59″ WEIGHT 8600 LBS. Aside from that, how much does a 1000-gallon concrete septic tank cost? The majority of septic tanks are constructed of concrete, although they can also be constructed of steel, fiberglass, or polyethylene. A 1,000-gallon precast concrete tank, which is sufficient for a three-bedroom house, typically costs between $600 and $1,000. In addition to the aforementioned, how can I calculate the size of my septic tank?

The majority of home septic tanks are between 750 and 1,250 gallons in capacity.

What is the maximum capacity of a septic tank?

Name Capacity
750 Gallon Septic Tank – 1 Compartment / 2 Manholes 750 Gallons
750 Gallon One Compartment Plastic Septic Tank 750 Gallons
750 Gallon 1 Compartment Plastic Septic Tank (Loose Plumbing) 750 Gallons
750 Gallon 1 Compartment NexGen Septic Tank (Loose Plumbing) 750 Gallons

Septic Tanks

Listed below is a list of the septic tanks, chlorine contact tanks, and siphon dose tank packages thatCamden Supplyoffers, along with detailed descriptions of their features and specifications. Please call Camden Supply and chat with one of our staff if you require further information on a certain product.

Single Compartment Septic Tanks

A one-compartment steel-reinforced concrete septic tank, according to the script. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 56 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 48 inches
  • Height to center line of outflow is 45 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


See also:  Why Does The Grass Die Ontop Of My Septic Tank? (Solution found)

600 Gallon Single Septic Tank

Specifications:

  • Overall height is 62 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of outflow is 49 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


1000 Gallon Single Septic Tank

Septic tank with a single compartment made of steel reinforced concrete (SRC). Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 96 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 8,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1250 Gallon Single Septic Tank

A one-compartment steel-reinforced concrete septic tank with the lower portion cast as a single piece so that there are no seams that come into touch with effluent. Specifications:

  • Overall height is 60 inches
  • Overall length is 117 inches
  • Overall width is 68 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,400 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psiApplications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1500 Gallon Single Septic Tank

Specifications:

  • Specifications:
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


25003500Gallon Single Septic Holding Tanks

Single Septic Holding Tank with a capacity of 2500 gallonsSpecifications:

  • Overall height is 68 inches
  • Overall length is 144 inches
  • Overall width is 78 inches
  • Height to center line of intake is 61 inches
  • Height to center line of outflow is 61 inches
  • Weight is 16,000 pounds.

It measures 68 inches in height, 144 inches in length, and 78 inches in width. The height to the center line of the inlet is 61 inches, and the height to center line of outlet is 61 inches. It weighs 16,000 pounds.

  • Overall height is 98 inches
  • Overall length is 144 inches
  • Overall width is 78 inches
  • Height to center line of intake is 91 inches
  • Height to center line of exit is 91 inches
  • Weight is 20,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


Dual Compartment Septic Tanks

Description:Two-compartment tank with solids separator between the first and second compartments, holding 500 gallons and 500 gallons, respectively. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 96 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1250 Gallon Dual Septic Tank

Description:Two-compartment tank with a solids separator between the first and second compartments, holding 625 gallons and 625 gallons. Specifications:

  • Overall height is 60 inches
  • Overall length is 117 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,700 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1500 Gallon Dual Septic Tank

Description:Two compartment system with a capacity of 1000 gallons in the first compartment and 500 gallons in the second compartment. The dosage pump portion is usually found in the second compartment. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 11,700 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


Triple Compartment Septic Tanks

Description:Three-compartment system with a solids separator between the first and second compartments. Each compartment holds 500 gallons. The dosage pump segment is usually found in the third compartment. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 12,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections. Available with pre-wired pump packages, complete with alarm, floats, and pump pad, with horse powers from 1/3 to 1.5, with up to 135 feet of total head capacity.


Chlorine Contact Tanks

Specifications:

  • Overall height is 56 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 48 inches
  • Height to center line of outflow is 45 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.500_gallon_chlorine_contact_or_grease_interceptor.pdfDownload File


Siphon Dose Tank Packages

Specifications:

  • It measures 56 inches in height, 79 inches in length, 48 inches in width, 48 inches in height from center line of intake, 48 inches in height from center line of outlet, and 5,000 pounds in weight. It is equipped with an indoor alarm and alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


1000 Gallon Siphon Tank Package

Specifications:

  • It measures 60 inches in height, 102 inches in length, and 67 inches in width. It measures 52 inches in height from the center line of the inlet and 52 inches in height from the center line of the outlet. It weighs 10,000 pounds. It comes with an indoor alarm and an alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

1250 Gallon Siphon Tank Package

Specifications:

  • It measures 60 inches in height, 117 inches in length, and 68 inches in width. It measures 52 inches in height from the center line of the inlet and 52 inches in height from the center line of the outlet. It weighs 10,400 pounds. It comes with an indoor alarm and an alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

1500 Gallon Siphon Tank Package

Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of intake is 52 inches
  • Height to center line of exit is 52 inches
  • Weight is 13,000 pounds
  • Includes indoor alarm and alarm float
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

1000 Regular

Regular septic tanks (model 1000) are the wastewater standard for the vast majority of residences. Featuring an integrated concrete input baffle as well as a Polylok PL-122 effluent filter with the industry’s first shut-off ball, this unit is a game changer.

Specifications:
  • The design of the septic tank is monolithic
  • The concrete is 4000 psi and set in 28 days
  • The rebar is structural fiber grade-60. Precast concrete with air entrained in it: 6 percent (+-1 percent)
  • Tank penetrations with rubber boots that are integrally cast
  • Designed for non-traffic loading applications. Fill depths range from 0 to 36 inches
  • Vacuum testing is offered for an extra fee.

The 1000 Regular septic tank is the wastewater standard for most residences, and it stores 1000 gallons of wastewater. Featuring an integrated concrete intake baffle as well as a Polylok PL-122/a>u00a0effluent filter with the industry’s first shut-off ball, this system is a must-have.

rn

Specifications:

rn

  • Septic tank design with integrally cast tank penetrations and rubber boots. 4000 psi concrete at 28 days. Reinforced with structural fibersamp
  • Grade-60 rebar. 6 percent (+-1 percent) air-entrained precast concrete. Vacuum testing is offered for an extra fee and may be done at any depth between 0 and 36 inches.rn The following are the attributes of the product:, description short:, available now:, available later:, id product27, out of stock:0, new:0, id product attribute:185, quantity wanted:1, extraContent:, allow oosp:true, category: septic-systems, category name: Septic Systems, link:, attribute price:0, price tax ex pricing parameters: 0
  • Customizations: 0
  • Rate: 0
  • Tax name: 0
  • Ecotax rate: 0
  • Attributes comma lists: 0
  • Attributes simple: 0
  • Unit price: 0
  • Customizations: 0
  • Is customizable: false
  • Show quantities: false
  • Quantity label: Item
  • Customer group discount:0
  • Title, 1000
  • Imagery on a regular basis:] The following are the defaults for the cart and the home page. The following are the defaults for the medium and the big page. The following are the defaults for the cart and the large page. id image: 52, position: 1, associatedVariants:, has discount:false, discount type:null, discount percentage:null, discount percentage absolute:null, price amount:0, regular price amount:0, regular price: $0.00, discount to display: $0.00, unit price full:, show availability:fals

Data sheet

Dimensions: 9 590 pounds; capacity: 1 000 gallon Exterior Dimensions64″ H x 5′-4″ W x 8′-0″ LInvert Out51 1/2″ Exterior Dimensions64″ H x 5′-4″ W x 8′-0″

Specific References

Part Number: A-AST-1000-1
Capacity: 1000 Gallons
Dimensions: 101″L x 60″W x 60″H
Availability: In Stock
Ships From: IA
*Stock subject to change. Please call to confirm.
Description:Ace Roto-Mold septic tanks are stronger, easier to install, and less costly than old-fashioned concrete septic tanks- yet they still offer the quality construction and safety you expect. Manufactured from high-density polyethylene with U.V. inhibitors, Ace Roto-Mold tanks utilize a horizontal flow designed for below ground installations up to 36 inches. Ace Tanks are IAPMO approved and have passed strenuous stress tests. Each tank carries an individual serial code and is fully document from date of manufacture. Ace Roto-Mold septic tanks are designed and manufactured with rigorous quality controls. The trapezoidal deep-rib design and interior baffle system make Ace Tanks the industry choice. Only Ace tanks feature a custom-molded gasket in the lid. Manufactured from extruded Nitrile rubber, the gasket snaps into the lid and ensures a watertight seal. Our exclusive lid design locks in place with nylon ties, eliminating the need for metal fasteners that can corrode and fail.
SKU A-AST-1000-1
Part Number A-AST-1000-1
Mfr. Part Number AST-1000-1
Capacity (Gallons) 1000
Dimensions 101″L x 60″W x 60″H
Weight (lbs) 441
Material Polyethylene
Manufacturer Ace Roto-Mold / Den-Hartog
Availability In Stock
Technical DrawingsGuides
Technical Drawings View Technical Drawing
Shipping From IA
Freight Class 300
Shipping Length 101
Shipping Width 60
Shipping Height 60
Shipping Weight (lbs) 441

1000 Gallon Septic Tank – Single Compartment. 60”D x 51”H x 127”L

  • Household wastewater treatment, on-site sewage treatment, residential applications, light commercial hotels, schools, and neighborhood applications, and more are available.

Notes

  • All images and drawings are for illustrative purposes only and may not always depict the exact product being advertised. It is possible for dimensions on polyethylene tanks to differ by +/-3 percent (typical rotational molding tolerance). It is recommended that venting systems be sized to provide for a maximum pressure or vacuum of 1/2″ water column (0.018 PSI) in polyethylene water tanks when used for water storage exclusively at atmospheric pressure. The tank is composed of BPA-free and FDA-approved materials. The resin is produced in NSF-certified manufacturing facilities. The tank must be installed and used in accordance with the manufacturer’s instructions for usage and installation in order for the warranty to be valid. According to the tank manufacturer’s guidelines, flexible connectors must be used on all fitting connections.
  • BPA-free and FDA-compliant
  • High-quality and long-lasting construction
  • 3-Year Manufacturer’s Warranty
  • Currently in stock and available for purchase

$1,590.00 in U.S. dollars Prices on all items displayed on our website are subject to change as a result of resin price changes that are beyond our control. Please contact our office to obtain verified price or to be placed on our waitlist for future availability (866-969-9404). Shipping and Handling Information

Ships From CA, NE, AR, WV, GA
Shipping Cost Call 866-959-7593 for Shipping Quote

Description

Septic tank with a single compartment made of HDPE. High-quality storage capacities are achieved via the use of state-of-the-art one-piece seamless construction. 1000 Gallon Single Compartment Schematic Illustration

Capacity 1000
Length 127″
Width 60″
Height 51″
Material High Density Polyethylene (HDPE)
Weight 250
Inlet 3″ Pre Drilled hole with Septic T and Gasket
Outlet 3″ Pre Drilled hole with Septic T and Gasket
Lid Size/type (X2) 20″ NexGen D2 Lid and Gasket
Specific Gravity 1.0 (Septic use only)
Manufacture Snyder

Additional Information

SEPTIC TANKS-Specifications- Pricing
500 GALLON PUMP TANK
LENGTH 68″, WIDTH 64″, HEIGHT 54″, WEIGHT 5500 LBS. INLET FLOW TO BOTTOM OF TANK 44� 0UTLET 41″.
1000 GALLON SEPTIC TANK
LENGTH 102″, WIDTH 69″, HEIGHT 59″, WEIGHT 8600LBS. INLET FLOW LINE TO BOTTOM OF TANK 49″, OUTLET 46″.
1000 GALLON LOWBOY SEPTIC TANK
LENGTH 154″, WIDTH’ 69″, HEIGHT 46″ WEIGHT 9900 LBS. INLET FLOW LINE TO BOTTOM OF TANK 36″, OUTLET 33″.
1 000 GALLON ROSIE 2 COMPARTMENT SEPTIC TANK
LENGTH 154″, WIDTH 69″, HEIGHT 46″, WEIGHT 10,000 LBS. INLET FLOW LINE TO BOTTOM OF TANK 36″, OUTLET 33″.

A 500-gallon tank that measures 51 inches high by 62 inches wide by 60 inches long, and a 750-gallon tank that measures 51 inches high by 62 inches wide by 103 inches long.

A 1000-gallon tank that measures 51 inches high by 118 inches long, and a 1500-gallon tank that measures 51 inches high by 177 inches long.

Concrete Septic Tanks Are Probably The Best Option — Build With a Bang

Concrete Septic Tank with a Capacity of 1000 Gallon When it comes to septic systems, whether you’re in the market for a new system or just need a replacement tank, you’ve arrived to the perfect location. As part of our recent investigation into different types of septic systems that are available for your house, we decided that it would be a good idea to also investigate the many types of septic tanks now available on the market. The following are the three most common types of septic tanks that are easily accessible for installation: When constructed properly and maintained on a regular basis, the majority of concrete septic tanks may endure for up to 40 years.

  • Waste flow, home size, square footage, number of bedrooms, number of bathrooms, and a few other factors are taken into consideration in septic tank size recommendations and charts.
  • Septic tanks are available in a variety of sizes, and you can even obtain tanks that are smaller than 1000 gallons; however, we recommend that you go with a tank that is at least 1000 square feet in size.
  • Consult with a licensed expert before purchasing or installing any equipment if you’re going to install a new septic tank or septic system for the first time.
  • ” A few of states are now requiring 1000 gallon tanks as the minimum size requirement.
  • The popularity of the concrete septic tank can be attributed to its strength, weight, and longevity.

Check out these 6 septic systems available for your home.

Nowadays, most concrete septic tanks are sold with a two compartment design, as opposed to the earlier style one compartment tank that was more common previously. Two compartment tanks tend to perform a better job of filtering and separating waste than one compartment tanks, which is why septic experts advocate them over a single compartment tank. All compartments are constructed with access for cleaning and pumping, regardless of the number of compartments in the system. Because it can readily handle most 0-3 bedroom dwellings, a 1000 gallon septic tank is the standard size for domestic applications.

Heavy Duty Options

Many tanks are also available in “high duty” configurations, which generally have a reinforced top and bottom.

Purchasing the heavy-duty version may be a wise decision in the case that a vehicle, agricultural equipment, or other large piece of heavy machinery passes over the tank area.

Installation Requirements

Because of the size and weight of concrete septic tanks, they must be installed by a qualified specialist. These tanks are constructed of the hardest materials available, and while they are extremely durable, their installation necessitates the use of enormous, heavy machinery. If the intended or present site of your concrete septic tank does not allow for heavy machinery access, you may want to investigate a fiberglass or plastic (polyethylene) tank. Due to the fact that the majority of concrete tanks are precast, their sizes, weights, and dimensions are all different.

Lifespan and Durability

The method by which the concrete septic tank was constructed will have an impact on its long-term function. High-quality concrete, adequate water sealing, and the use of structural steel goods such as mesh and rebar will provide additional support, strength, and structural integrity to the structure. Keep in mind that concrete septic tanks are more prone to cracking and leaking than their plastic and fiberglass equivalents when exposed to exceptionally cold temperatures and pressures. Most concrete septic tanks have a lifespan of up to 40 years if they are constructed properly and serviced on a regular basis.

1000 Gallon Concrete Septic Tank

Septic tanks of 1000 gallon capacity or larger are the most typical size for household usage, as they can readily fit most 0-3 bedroom dwellings. Size Weight: The weight of each concrete tank is different. Some of the most common 1000 gallon concrete precast tanks are around 5′ 1″ X 8′ 2″ X 5′ 8″ in size and weigh almost 9,000 lbs. Others are approximately 5′ 1″ X 8′ 2″ X 5′ 8″ in size and weigh almost 9,000 lbs. Here are some examples of Jensen Precast projects completed in various cities around the United States.

1250 Gallon Concrete Septic Tank

Generally speaking, a 1250 gallon tank is a good choice for mid-size homes with 3-4 bedrooms. Size and weight: The sizes and weights of all concrete tanks are different. 1250 gallon concrete precast tanks are typically 5′ 9″ x 8′ 6″ x 5’8″ in size, with some of the more common models being 5′ 9″ x 8′ 6″ and others measuring 5′ 8″. The typical weight of a 1250 gallon concrete tank is 11,000 lbs, however this might vary depending on the distributor. Approximately 11 1/2 feet in depth, however this varies according on the distributor, state, and local statutes.

1500 Gallon Concrete Septic Tank

Generally speaking, a 1500-gallon tank is the most popular size for large homes with five or more bedrooms. Size and weight: The sizes and weights of all concrete tanks are different. The dimensions of some of the most common 1500 gallon concrete precast tanks are around 6′ x 10′ 9″ x 5′ 5″ in length and width. The typical weight of a 1500 gallon concrete tank is 12,000 lbs, which is rather heavy.

Approximately 12 feet in depth, however this varies according on the distributor, state, and local statutes. Baffles at the input and output of the system aid in the separation of solid waste items, oils, and scum from the effluent.

Inlet Baffles

When installing a septic tank, an inlet baffle should be put on the inlet part closest to the point at which the sewer tank joins from the house structure to the tank. Due to the fact that it prevents scum and oils from blocking the entrance pipe, the inlet baffle is critical to the overall health and effectiveness of the septic system. The intake baffle is a bottle neck that is especially designed to do the following:

  • In order to prevent the breakdown process from being disrupted, it is necessary to slow the effluent entering the septic tank. A fast rate of inflow of effluent might cause problems by mistakenly combining the settled solid waste with oils, scum, and effluent. Make sure no sewage gases are allowed to enter the sewer line. These gases have the potential to infiltrate back into a home or structure, generating a foul odor.

Outlet Baffles

Every septic tank should be equipped with an exit baffle that is connected to the discharge line. The outlet baffle functions as a bottle neck in the same way as the inlet baffle, but in the opposite direction. It is meant to:

  • Preserving the septic tank by keeping scum, oils, and solid waste contained inside
  • It is necessary to prevent the discharge of waste items other than wastewater into the output pipe, drain field, and leach field.

All effluent from the septic tank must be clear of solid waste before it may be discharged. Other than that, the solids and oils will pollute the drain field/leach field and result in backups and pollutants entering the surrounding environment. Ensure that your baffles are correctly built and that they are not in need of repair by consulting with a licensed septic technician before doing anything else. Septic tanks made of fiberglass or polyethylene (polyethelyene) are also a suitable option, especially if your location has specialized environmental requirements.

Mobility

In contrast to concrete septic tanks, which normally need a vehicle equipped with a crane and boom, fiberglass and polyethylene septic tanks are quite simple to transport. Therefore, fiberglass and plastic tanks are frequently employed in places where concrete septic tank delivery vehicles are unable to reach the tanks. The majority of fiberglass and plastic septic tanks weigh roughly 300 pounds or more, however concrete septic tanks can weigh up to 20-30 times as much.

Cost Effectiveness

If you’re seeking for a less expensive alternative to concrete, fiberglass and polyethylene (polyethylene) are excellent choices. The majority of fiberglass and plastic septic tanks are thousands of dollars less expensive than concrete septic systems.

Durability

When compared to a concrete septic tank, both plastic and fiberglass septic tanks have a lower likelihood of breaking. Furthermore, because fiberglass and plastic are nonporous materials, there is typically no problem with tree or bush roots growing into the tank and generating leaks as a result of root damage. Having said that, due to the tank’s smaller profile and lighter material composition, caution must be used during installation because heavy gear might easily harm it. Tanks made of fiberglass or plastic can be destroyed in the same way as concrete tanks can if too much weight is placed on the surface above them.

Despite the fact that plastic and fiberglass tanks are quite resilient, they can nonetheless leak under specific circumstances.

As a result, it’s important to contact with a septic installation specialist before making a final decision on a certain material. The size of the lot, the position of the tank, the amount of ground water, and the weather can all influence the selection.

Float

Plastic and fiberglass have a number of advantages, but they can also be troublesome. Yes, the lightweight character of these materials makes them perfect for installation, but same lightweight nature also results in a high level of buoyancy in the final product. It is possible that during a storm, a plastic or fiberglass tank can get dislodged from its couplings, causing considerable damage to the septic system and the homeowner’s property, with repair costs in the hundreds of dollars. A simple solution is to place a concrete slab on top of the tank to help weigh it down.

If you reside in an area with a high groundwater table, consult with a specialist to ensure that the higher water table will not cause harm to your fiberglass or plastic tank.

Septic Tank-1000 Gal

Overview Septic tanks made of precast concrete are safe and dependable containment vaults that are used to naturally treat and separate wastewater. Tanks from Oldcaslte Infrastructure are waterproof, appropriate for moderate and high traffic loading circumstances, and are also ecologically conscious. These tanks, which come in a variety of conventional and configurable configurations, are the best alternative where municipal sewers are not an option. Grade ringsrisers, lifters, pulling irons, drainage sumps, and knockouts are all options for customizing your project to meet your specific demands and specifications.

  • The following terms are used in this document: Modular Construction, Base/Bottom Section, Lids/Top Sections, Body Slab and Risers, Rings/Cover, Embedded Lifters, Grade Rings and Risers, Knock-outs/Block-outs, Divider Walls.
  • Natural wastewater treatment and separation is made possible by the rugged durability of the system. Sectional design that may be customized
  • Installation is quick and simple. Design featuring distinct access points, block-outs, and knock-outs on each of the five sides
  • Base with four sides and an integral floor (body slab) as an alternative
  • The design of the panel part is optional. Various shapes and sizes are available. Covering and protecting
  • Accessibility for maintenance and inspection
  • Various shapes and sizes are available. Access openings of several sizes and locations are available
  • Customization to satisfy specific depth requirements
  • Various shapes and sizes are available. Various sizes are available. Cast or ductile iron covers for concrete manhole frames or concrete coverings for concrete manhole frames
  • Allow for simple installation
  • Material made of galvanized steel
  • 2, 4, 8, and 20-ton capacity loading capabilities. There are also one-ton universal lifters available. Covers for the access openings that are elevated above ground level
  • Available in both rectangular and circular configurations
  • Available in a variety of configurations to fit a wide range of inlet and output connection sizes and heights
  • Custom round or rectangular forms are available based on your design parameters. In order to get the correct fit, knock-outs may be readily shattered with a hammer. The customer is responsible for installing baffles and pipework. Baffles made of precast concrete are installed in the base portion. Create a barrier to slow down effuient and keep solids in place.

Location Available

Middle Island, New YorkX114 Rocky Point RoadMiddle Island, New YorkX

Quote Generator

Middle Island, New YorkX114 Rocky Point Road

What size of septic tank do I need?

Probably one of the last things on your mind when you are constructing a new house is the location of your septic system. After all, shopping for tanks isn’t nearly as entertaining as shopping for cabinetry, appliances, and floor coverings. Although you would never brag about it, your guests will be aware if you do not have the proper septic tank placed in your home or business.

septic tanks for new home construction

The exact size of the septic tank is determined mostly by the square footage of the house and the number of people who will be living in it. The majority of home septic tanks have capacities ranging from 750 to 1,250 gallons. A 1000 gallon tank will most likely be required for a typical 3-bedroom home that is smaller than 2500 square feet in size. Of course, all of this is dependent on the number of people who live in the house as well as the amount of water and waste that will be disposed of through the plumbing system.

For the most accurate assessment of your septic tank needs, you should speak with an experienced and trustworthy sewer business representative. They can assist you in planning the intricacies of your septic system, including which sort of septic system will be most beneficial to you.

planning your drainfield

Here are some helpful hints for deciding where to locate your drainfield when you’re designing it.

  • Vehicles should not be allowed on or around the drainfield. Planting trees or anything else with deep roots along the bed of the drain field is not recommended. The roots jam the pipes on a regular basis. Downspouts and sump pumps should not be discharged into the septic system. Do not tamper with or change natural drainage features without first researching and evaluating the consequences of your actions on the drainage field. Do not construct extensions on top of the drain field or cover it with concrete, asphalt, or other materials. Create easy access to your septic tank cover by placing it near the entrance. Easy maintenance and inspection are made possible as a result. To aid with evaporation and erosion prevention, plant grass in the area.

a home addition may mean a new septic tank

Do not make any big additions or renovations to your house or company until you have had the size of your septic system assessed. If you want to build a house addition that is more than 10% of your total floor space, increases the number of rooms, or necessitates the installation of new plumbing, you will almost certainly need to expand your septic tank.

  • For a home addition that will result in increased use of your septic system, your local health department will require a letter from you that has been signed and authorized by a representative of your local health department confirming that your new septic system is capable of accommodating the increase in wastewater. It is not recommended that you replace your septic system without the assistance of a certified and competent contractor.

how to maintain your new septic system

Septic tank cleaning and septic tank pumping services are provided by Norway Septic Inc., a service-oriented company devoted to delivering outstanding septic tank cleaning and septic tank pumping services to households and business owners throughout the Michiana area. “We take great delight in finishing the task that others have left unfinished.” “They pump, we clean!” says our company’s motto. Septic systems are something we are familiar with from our 40 years of expertise, and we propose the following:

  • Make use of the services of a qualified specialist to develop a maintenance strategy. Make an appointment for an annual examination of your septic system. Utilize the services of an effluent filter to limit the amount of particles that exit the tank, so extending the life of your septic system. Waste items should be disposed of properly, and energy-efficient appliances should be used. Make sure you get your septic system professionally cleaned every 2 to 3 years, or more frequently if necessary, by an experienced and qualified expert
  • If you have any reason to believe that there is an issue with your system, contact a professional. It is far preferable to catch anything early than than pay the price later. Maintain a record of all septic system repairs, inspections, and other activities

common septic questions

Hire a qualified specialist to assist you in developing a maintenance strategy; and Maintain your septic system by scheduling an annual inspection. Utilize the services of an effluent filter to limit the amount of particles that leave the tank, so extending the life of your septic system. Use Energy-Efficient Appliances and properly dispose of waste products. Every 2 to 3 years, or as often as is necessary for your system, have your septic system cleaned by an experienced and qualified specialist.

Avoiding a problem in the first place is vastly preferable to paying a high price later.

How do I determine the size of my septic tank?

If you have a rectangular tank, multiply the inner height by the length to get the overall height of the tank. In order to find out how many gallons your septic tank contains, divide the number by.1337.1337

How many bedrooms does a 500-gallon septic tank support?

The exact size of the septic tank is determined mostly by the square footage of the house and the number of people who will be living in it. The majority of home septic tanks have capacities ranging from 750 to 1,250 gallons. A 1000 gallon tank will most likely be required for a typical 3-bedroom home that is smaller than 2500 square feet in size.

How deep in the ground is a septic tank?

Your septic system is normally buried between four inches and four feet underground, depending on the climate.

Dimension List – Arizona Precast Septic Concepts LLC

44 inches in length and 44 inches in width Height-4’4″ Approximately 39 inches from the bottom of the tank to the bottom of the stub out From the bottom of the tank to the bottom of the stub out, the outlet is 37 inches.

ACTUAL SIZE

4’8″ in length, 4’8″ in width Height-4’9.5″ Approximately 45 inches from the bottom of the tank to the bottom of the stub out Outlet approximately 43 inches from the bottom of the tank to the bottom of the stub out

ACTUAL SIZE

Length: 9’9″ (bottom) and 10’5″ (top) (top) Width: 4’2′′ (bottom) and 4’9′′ (top) (top) Height-5’11” Approximately 54 inches from the bottom of the tank to the bottom of the stub out From the bottom of the tank to the bottom of the stub out, the outlet is 52 inches.

HOLE DIMENSIONS

11’7″ in length, 6’6″ in width

ACTUAL SIZE

Length: 9’9″ (bottom) and 10’5″ (top) (top) Width: 4’8″ (bottom) 4’9″ (top) (top) Height-6’1″ the length of the inlet pipe from the bottom of the tank to the bottom of the stub out Inlet-56 inches from the bottom of the tank to the bottom of the stub out.

HOLE DIMENSIONS

11’5″ in length, 6’3″ in width

ACTUAL SIZE

9’8″ (bottom) and 10’5″ (top) in length (top) Width-6’6″ Height-6’3″ the length of the inlet pipe from the bottom of the tank to the bottom of the stub out Inlet-56 inches from the bottom of the tank to the bottom of the stub out.

HOLE DIMENSIONS

11’3″ in length, 7’10” in width

ACTUAL SIZE

The length is 12’10” and the width is 5’8″. 5’7.5″ in height is the maximum. Inlet – 55 inches, outlet – 52 inches

HOLE DIMENSIONS

14 feet in length 7.5 feet in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-5’11” It measures 55 inches from the bottom of the tank to the bottom of the stub out and 53 inches from that same bottom to the bottom of the stub out. Inlet: 55 inches from the bottom of the tank to the bottom of the stub out

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’6.5″ in length, 5’8″ in width, and 5’7.5″ in height Approximately 55 inches from the bottom of the tank to the bottom of the stub out From the bottom of the tank to the bottom of the stub out, the outlet is 52 inches.

HOLE DIMENSIONS

Length-16′ Width-7’6″

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-6’4″ From the bottom of the tank to the bottom of the stub out, the inlet is 60 inches. From the bottom of the tank to the bottom of the stub out, the outlet is 58 inches.

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-6’10” From the bottom of the tank to the bottom of the stub out, the inlet is 66 inches. Outlet-64 inches from the bottom of the tank to the bottom of the stub out

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-7’5″ From the bottom of the tank to the bottom of the stub out, the inlet is 73 inches. from the bottom of the tank to the bottom of the stub out, outlet-71′′

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-9’1″ From the bottom of the tank to the bottom of the stub out, the inlet is 93 inches. From the bottom of the tank to the bottom of the stub out, the outlet is 91 inches.

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-10’7″ Inlet-111′′ measures the distance from the bottom of the tank to the bottom of the stub out. From the bottom of the tank to the bottom of the stub out, the outlet is 109 inches.

HOLE DIMENSIONS

15’10” in length, 8’10” in width

ACTUAL SIZE

14’4″ in length, 6’6″ in width Height-11’1″ From the bottom of the tank to the bottom of the stub out, the inlet is 116 inches. From the bottom of the tank to the bottom of the stub out, the outlet is 114 inches.

HOLE DIMENSIONS

15’10” in length, 8’10” in width 15.5 inches in length, 11 inches in width, and 10.5 inches in height

Other sizesavailable upon request

8′′X8′′ taper to 6.75′′X6.75′′6′ long x 6′′ tall x 8.5′′ wide 8′′X8′′ taper to 6.75′′X6.75′′ 47 inches in length, 5 inches in height, and 9 inches in width

Other sizes made upon request

24 inches inside diameter, 34 inches outside diameter

Leave a Comment