How To Install A Septic Tank Riser On A Rectangular Opening? (Correct answer)

  • Remove the existing lid on the septic tank. Install an adapter ring in the opening to the septic tank. The risers will attach directly to this ring. Secure the ring to the tank by using concrete.

Are septic tank risers stackable?

Risers are used to bring the access of your septic tank to grade. Choose any combination of the options below to achieve the required height that you would like for your septic tank riser kit. The Polylok risers are stackable.

Should I install a septic tank riser?

Having a riser in place can also significantly reduce the cost of septic tank maintenance over time through the ease of access and time on the job saved. Plus you will be spared digging up your lawn every time as well.

How many septic tank risers do I need?

A single riser is required for accessing the pump chamber for this type of system. If you don’t have two additional risers, you should locate your septic tank and install risers for both the inlet and outlet openings, as described above.

Should septic tank lid be sealed?

Like wells, septic systems have problems if they are not sealed from outside surface water. Most septic systems rely on buried pipes to get rid of the fluids. The lid covers should fit tightly — if they don’t, a company that specializes in septic repairs should be called to fix them.

How much weight can a septic tank riser lid hold?

The 24-inch solid fiberglass DuraFiber riser lid from Orenco Systems has a flat-style lip for PVC and HDPE pipe. It weighs 10 pounds, but resists damage from lawn equipment and can withstand a 20,000-pound load.

What diameter is a septic tank riser?

Typical septic tank riser diameter is 24-inches but 30-inch, 16-inch and other riser diameters are available. Risers are sold in varying heights from 6″ and up.

What sizes do septic tank lids come in?

Available in 12″, 16″, 20″ and 24″ diameters. Green only. 12″ Tall Riser – For septic tanks.

How to Install Risers and Lids on Concrete Septic Tanks w/ Square Hole

Be explicit about what we’re talking about. When you perform a basic search on the Internet, list after list of stuff that should not be flushed appears. Views from this vantage point are often rather overpowering and even a bit frightening. The only list to keep in mind is the one including only items that are safe to flush down the toilet. Waste and toilet paper are included on this list. It is necessary to dispose of all other items in another manner. Maintaining vigilance over what is flushed has a positive impact on the safety of the water supply and, as a result, the health of humans and animals.

What belongs in the toilet should remain in the toilet, while the remainder can be disposed of in the garbage.

Installing Access Risers

In order to perform fundamental septic system maintenance, you must first evaluate the condition of your septic tank and pump chamber (if you have one), which can be time-consuming and labor-intensive if you do not have access ports known as risers. Consider the prospect of having to dig through two feet of dirt to check the oil on your vehicle. Installing septic tank risers for an off-site septic system is broken down into four steps, which are outlined below. Please keep in mind that the currentWashington State Coderequiresrisers for all septic systems, which means you may be forced to install one if you are asking for a construction permit, land division, or any other type of official action in the state.

A few safety tips before you get started:

  • Struck by an underground electrical wire while excavating may be quite dangerous! If you are in any way doubtful about the presence of subterranean lines on your property, you can have them found by contacting 1-800-424-5555 or 811, or by visiting the website
  • Use the buddy system to your advantage! Working with a partner is usually recommended since the fumes connected with open sewage can be dangerous and cause a person to go unconscious. Never leave a septic tank that is open unattended! Once the lids have been removed, exercise caution around the tank and keep dogs and children at a safe distance. Examine the structural integrity of your septic tank! If a septic tank is more than 20 years old, it is recommended that it be pumped to ensure that the tank’s structural integrity and water-tightness are not compromised. Instead of spending money on costly repairs, it is preferable to replace the tank with a contemporary septic tank that includes risers as part of the installation. A permit from your local Environmental Health department is required for the replacement of a septic tank.

Gather all the MaterialsTools You will Need

It should be possible to get most of the components required to construct a septic tank riser at your local plumbing hardware store or on the internet. PVC risers are available in a variety of shapes and sizes. Some of the brand names you might be familiar with include “Tuf-Tite,” “Polylok,” and “Orenco.” Risers are typically 24 inches in diameter and may be readily inserted into the tank hole opening without difficulty. Due to the fact that certain tanks have square openings, it might be difficult to fit a riser around the square entrance.

Some types of risers are made to order based on the height you want, while others are available in increments of 6-12 inches.

Then purchase an Adapter and Risers that are somewhat bigger in diameter than the hole.

See below for Step 4 on attaching risers to the tank entrance.

  1. It should be possible to get most of the components required to construct a septic tank riser at your local plumbing hardware store or on the Internet. A variety of PVC risers are offered in various configurations. Tuf-Tite, Polylok, and Orenco are just a few of the brand names you might be familiar with. Risers are typically 24 inches in diameter and may be readily inserted into the tank hole opening with no difficulty whatsoever. Fitting around a riser above a square aperture in certain tanks can be difficult since some tanks have square openings. In order to accommodate this, square plate adapters with round apertures are now available. Others come in 6-12-inch increments and are custom-cut to the height you want, while others are available in pre-cut lengths. NOTE: You will need to measure the size of the hole in your septic tank before you can begin the process. Buy Adapter and Risers that are slightly bigger in diameter than the hole. The 24 inch Tank Adapter Ring, the 24 inch Risers, and the 24 inch Lid are required if, for example, the hole in your septic system is 22 inches across at its widest point. Fitting risers to the tank entrance is covered in detail in Step 4. The following components will be required to build a riser system on your septic tank:

It should be possible to get most of the components needed to build a septic tank riser at your local plumbing hardware store or on the internet. PVC risers are available in a variety of styles. Some of the brand names you may be familiar with include “Tuf-Tite,” “Polylok,” and “Orenco.” Risers are typically 24 inches in diameter and may be readily inserted into the tank hole opening with minimal effort. Some tanks have square apertures, which makes it difficult to put a riser around the square hole.

Some types of risers are made to order based on the height you want, while others are available in 6- to 12-inch increments.

Then purchase the Adapter and Risers that are somewhat bigger in diameter than the hole.

See below for Step 4 on how to attach risers to the tank entrance. A riser system for your septic tank will require the following components:

  1. As-built condition of the sewage treatment system The following items are required: sketch on paper, measuring tape, shovel, probing instrument, eye protection, and work gloves.

To cut risers to the proper size, the following tools are required:

  1. Circular saws, saber/jig saws, and hand saws
  2. Raspor file
  3. Marking pen
  4. Tape measure
  5. Drill with a 1/4″ bit

Materials required to seal the risers to the tank include:

  1. It will be necessary to use the following materials to secure the risers to the tank:

Follow the four simple procedures shown below to install access risers on your septic components, or download and print a copy of theSeptic Tank Manhole and Access Riser Installationbrochure from Thurston County Environmental Health to get started right now.

Step 1: LocateYour Septic Tank(s)

When looking for your underground septic tank or tanks, it is essential to consult the ‘As-built’ Record Drawing linked with your septic system for assistance. Essentially, this is a plot diagram that shows where your septic system was put on your property, as well as distances between septic components and notable landmarks. The Online Permit System will guide you through the process of locating septic-related documentation if you do not have a “as-built” document. It is possible that you may need to contact Environmental Health to examine the paper records or seek a specialist to find your tank if an as-built is not accessible.

Probing the area around the septic tank with the probing instrument until you contact concrete should be done lightly.

The presence of underground electricity or other utility lines and cables might put your septic tank in danger.

Call 1-800-424-5555 or 811 or go online to make sure that any electrical utilities are found before you begin digging before you begin digging.

Step 2: Uncover Your Septic Tank (s)

Once you’ve discovered your septic tank, you may start digging about. The tank is typically 6 feet wide by 8 feet long, with the width being the largest size. Remove all of the pebbles and debris from around the tank’s lid openings and dig out the whole top of the tank. You will want to clean out any dirt that has accumulated on the surface of your septic tank. This will assist you in ensuring that you generate a high-quality seal. You should have two openings: one over the inlet (which comes from the home) and another over the outlet (which comes from the yard) (into the drainfield or pump chamber).

  • You’ll need a riser for each of the doors you open.
  • Typically, the inlet side is the one that is nearest to the home.
  • When cleaning the tank, it is beneficial to remove the complete top of the tank.
  • Risers must be modified in order to be correctly installed, and all manholes (holes 24 inches or bigger in diameter or square in shape) must also be updated, as well as the tankinlet and outlet baffle covers (if separate from the manholes).
  • If you discover one – and only one – riser already installed, it is most likely for the pump chamber, which only requires a single riser to provide access to the pump to function properly.
  • Remove the concrete lids so that they may be disposed when the project is completed.
  • Consult your’As-built’Recorddrawing to establish whether you have a distribution box (D-box), which you will also need to unearth and place a riser on if you have a typical gravity system.
  • Once the lids have been removed, proceed with caution around the tank.
  • Inform someone of your whereabouts in case you are involved in an accident.

You should be aware that exposure to sewage can result in serious sickness, so make sure you wear gloves and thoroughly wash your hands afterward with soap and water. It is also recommended that you wear eye protection in the event that debris falls into a tank and splashes back at you.

Step 3: Fit Risers to Component Openings

In accordance with the diameter of the septic tank manholes, huge risers will either sit on top of the septic tank or will fit down into the aperture of the tank by 1-3 inches. It’s important to keep this in mind while calculating the height of the riser. The surplus can be easily removed; nevertheless, it is difficult to add a few inches to the length. Take the following measurements of the manhole cover’s diameter:

  • Large risers will either rest on top of the septic tank or fit down into the tank opening by 1-3 inches, depending on the diameter of the septic tank manholes. When establishing the height of the riser, keep this in mind as you measure. The additional length may be easily removed
  • However, it is quite difficult to add a few inches. Obtain the following measurement of the manhole cover’s circumference:

Large risers will either rest on top of the septic tank or will fit down into the tank opening by 1-3 inches, depending on the diameter of the septic tank manholes. When selecting the height of the riser, keep this in mind. The surplus can be easily removed; nevertheless, it is difficult to add a few inches to the overall length. Take the following measurements of the manhole cover:

Step 4: Attach Risers toSeptic Tank (s)

It is recommended to pump out an old septic tank that is 20 years or older in order to check its structural integrity and water-tightness before using it again. If the tank requires extensive repairs, it is preferable to replace it with a new septic tank that includes risers as part of the installation. A permit from the local health department is required for the replacement of a septic tank. Remove any dirt and debris from the tank’s surface by cleaning it off. Using the butyl rope, construct the components of the risers in accordance with the manufacturer’s instructions.

  • Jet-Set, Rapid-Set, Thorough-Set, and Perco-Plug are just a few of the brand names available.
  • NOTE: For optimal results, just a little amount of concrete patch should be mixed at a time.
  • The patch mix should be used to seal the riser to the septic tank.
  • If you want to avoid a safety danger, make sure you properly attach theriser lid using the screws that come with it!
  • Risers for inlet or outlet apertures that are smaller than the openings should have the bottom few inches sanded with rough sandpaper to allow a firmer connection between the two surfaces.
  • A useful source of information on correct installation of risers on septic tanks may be found at your local hardware store where you purchased the risers and covers.

Thurston County Environmental Health is should be commended for providing the foundation for this documentation.

How To Instal Risers On A Septic Tank

A septic tank riser system will be installed today, and we will demonstrate how to do it. If you have a concrete septic tank that does not have risers built, this instruction is for you. It is currently mandatory in many areas to have risers and lids installed on your septic tank. When it comes time to have your septic system pumped out, installing a riser system can also save you money. Please follow the instructions in the following section and you will have no difficulties.

See also:  What To Look For In A Septic Tank Inspection? (TOP 5 Tips)

Step 1 – Gather The Parts You Need

The following things will be required for the installation of a riser system on your septic tank. (Click on the item to make a purchase.) Tuf-Tite Tank Adapter Ring (optional) (TAR) 2)Riser Adapter Rings Kit (includes riser adapter rings) Butyl Rope (number three) Tip-Tite Risers are a type of tie-down device. 5)Tuf-Tite Domed Lid (optional). ORTuf-Tite Flat Lid (Ortuf-Tite Flat Lid) 6) Screws made of stainless steel Keep in mind that you will have to determine the size of the hole in your septic tank.

Consider this: If the hole in your septic system is 22 inches across at its widest point, you will need to purchase the 24 inch Tank Adapter Ring, 24 inch Risers, and 24 inch Lid.

Step 2 – Clean The Top Of Your Septic Tank

You will want to clean out any dirt that has accumulated on the surface of your septic tank. In doing so, you will increase the likelihood of successfully creating a good seal. A concrete ring is seen on the left side of the image. Using this as an example, we will illustrate how to install a riser system. In order to offer a visual picture of a hole in a concrete septic tank, the following image was created. The diameter of this one is 16 inches. It is possible that your hole is bigger or smaller.

Remember to measure the hole diagonally before purchasing the appropriate Tuf-Tite Tank Adapter Ring.

Step 3 – Apply Butyl Rope To Tank Adapter Ring

The debris that has accumulated on the surface of your septic tank should be removed. This will aid in the creation of a high-quality seal for you. A concrete ring is seen on the left side. A riser system is being installed, and we are demonstrating how to do it. In order to offer a visual picture of a hole in a concrete septic tank, the following image has been created: In this case, the circumference is 16′′. If you have a larger or smaller hole, let us know! If you have a square hole, this will function in the same way that it does now.

Step 4 – Put Adapter Ring Around Hole And Screw It Down

Firmly push the Tuf-Tite Tank Adapter Ring onto the septic tank’s adapter ring to secure it. To begin drilling the holes, use the drill bit that included with the package.

The Adapter Ring will have divots in the areas where the holes will be located. Once you have pre-drilled the holes, you may use the blue concrete tapping screws that are provided to secure the ring to the top of your installation system.

Step 5 – Add Butyl Rope To The Bottom Of Each Riser

The bottom of each riser will have a recessed ring in the center. In this ring, insert a strip of butyl rope and tighten it. This will ensure that the risers are watertight.

Step 6 – Put Risers and Lids On The Adapter Ring

Now it’s time to attach your risers to your Adapter Ring. Their installation will be accomplished by screwing them into place using stainless steel screws. In order to raise it to the proper height, you can use as many risers as necessary. That’s all there is to it. You have completed the installation of a riser system on your septic tank, which should pass inspection anyplace in the United States of America.

Polylok Square Septic Tank To Riser Adapter Ring – 3009-AR

  • Tank may be fitted with Polylok Risers and Lids that are either 20″ or 24″ in diameter
  • It has a maximum opening of 25″ square or 27″ round
  • It has a large, flat surface area that makes tank mounting simple.

The adapter ring is the first component that you’ll need to put together in order to assemble a full riser system. The adapter ring attaches directly to the septic tank, allowing the risers to stack, lock, and mount to it without the need for any additional hardware. Having this component is critical since the risers are not flat on the bottom because they are meant to be stackable, and it is not feasible to install them straight to the septic tank without this piece. The adapter ring provides the flat surface you need to mount to the tank while also being able to accommodate the stackable risers that are included with the tank.

Our square tank adapter ring can accommodate big square apertures up to 25 inches in diameter and large round openings up to 27 inches in diameter.

They are intended to be used with openings that are 24″ or less in diameter.

Concrete anchors, a masonry bit for installing the anchors, and butyl sealer are all included in this set.

ADAPTER RING INSTALLATION

1.Clean the tank surface area over the aperture where the riser adapter ring will be installed; a minimum of 36″ of space should be left for the riser adapter ring. Check the plug size to ensure that the riser is not obstructed. 2.Place the riser adapter ring on the tank surface and mark the anchor locations using the anchor holes in the adapter ring. The 24″ position will necessitate removal of the 20″ ring, thus choose the appropriate size riser for your needs. To remove the riser adapter ring, turn it over and cut along the score line to release it.

Anchors might be any of the anchors that are usually accessible.

If you are using butyl mastic or silicone sealants, insert the riser-sealing strip on the bottom of the riser adapter ring in the proper location for the riser size that you are using.

Additional risers should be inserted into the riser adapter ring, with the screw holes aligned to ensure that the portions of the risers are securely fastened together.

8. Attach the riser cover to the top of the riser using the screws that were provided. 9.The installation is complete, but if FROST is present in your region, you may wish to remove the riser rings from any further risers before final backfilling it.

Polylok Septic Tank Risers

Nowadays, there are several different types and designs of septic riser kits and packages available on the market. Building a septic riser kit with Polylok goods will ensure that you are getting the most value for your money. There are several causes for this, but the following are the most significant:

FACTORY INSTALLED GASKETS

The Polylok brand is the only one on the market that is sent to you from the factory with gaskets already in place, making it unique. This means that there is no further work necessary to ensure that the riser system is air and water tight! Keep ground water out of your tank, wastewater in your tank, and potentially hazardous gases out of your yard! In contrast to most other products, our Polylok septic tank risers do not require you to purchase or use any other type of sealant between each riser part.

INTERNAL STRUCTURAL RIBS

Once the hole has been backfilled, the structural ribs in the Polylok septic tank risers are inserted inside around each riser piece, providing them with tremendous strength and allowing them to maintain their shape under the pressure of the earth being pressed on them. As a result of the freezing and thawing of the ground in many parts of the country, it is necessary to have a smooth surface on the outside of the riser’s exterior. It is possible for items that have structural support on the outside of the riser to actually be lifted from the tank, causing damage to both the riser and seal, during periods of freezing and thawing.

LOW PROFILE RISER LIDS WITH HANDLES

The septic tank access lid on a riser system is one of the most significant components since it is the part of the system that is visible from the outside and that must be removed every time the system is pumped or otherwise serviced. The Polylok lids are pre-installed with handles, which make it simple to remove the lid whenever you need to get access to the system or to replace it. The bottom of the lids is structurally supported, which allows them to remain relatively flat rather than domed in shape, as is the case with many other items on the market.

LARGE TANK ADAPTER RING

As the most visible component of your riser system, the septic tank access lid is also one of the most vital since it is the component that must be removed every time the system is pumped or repaired. Handles are pre-installed on the Polylok lids, which make it simple to remove the lid whenever you need to get access to your system. It is also possible for the lids to be relatively flat rather than domed shaped like many other goods on the market since they are structurally supported on the bottom.

STAINLESS STEEL SCREWS INCLUDED

At Septic Solutions, we strive to make the buying and installation process as simple as possible for our customers. All of our Polylok Septic Tank Risers and Lids are delivered with all of the stainless steel screws required for installation in one package.

Septic Tank Risers & Lids

SAME DAY SHIPPING ON ALL SEPTIC TANK RISERS, LIDS, AND ADAPTERS WITH FAST AND FREE SHIPPING.

Polylok SQUARE Riser Adapter Ring

An existing concrete tank with big square or round apertures may be connected to a Polylok square riser adapter ring, which is designed to attach Polylok septic tank risers or lids to the existing concrete tank.

The adapter ring attaches directly to the tank and takes the risers and lids as accessories. It is made of stainless steel. Use ourInstallation Kitbelow to make the process as simple as possible. Specifications of the product

  • Accepts Polylok Risers and Lids in either 20″ or 24″ widths
  • Covers a maximum of 25″ square or 27″ diameter openings
  • Tank mounting is made simple by the large, flat surface area.
Availability: IN STOCK
Technical SpecificationsWatch MoreAbout Polylok Risers

If you want technical assistance, please contact our support department at 1-877-925-5132.

Polylok ROUND Riser Adapter Ring

For technical assistance, please contact our support department at 1-877-925-5132.

  • Available in two sizes: 20″ and 24″ in diameter. Polylok may be used to adapt round openings or existing Risers to the material. Tank mounting is made simple by the large, flat surface area. Availability: AVAILABLE IN STOCK
Adapts 20′ or 24′ Round Openings or Risers to Polylok Risers and LidsWatch MoreAbout Polylok Risers

Put your trust in the professionals with more than 20 years of expertise in the wastewater business.

Polylok Septic Tank Riser Lids

The Polylok septic tank riser lids are designed to suit only Polylok septic tank risers or adapter rings, and they are not compatible with any other brands. The lid snaps into place and is secured in place with stainless steel screws that are provided. Specifications of the product

  • Easy removal is made possible by the flip up handles
  • A factory installed gasket provides a watertight seal
  • Stainless steel screws are included
  • Only Polylok Risers and Adapter Rings are compatible with this product. Availability: AVAILABLE IN STOCK
Replaces Models PL-20RC, PL-24RCTechnical Specifications Watch MoreAbout Polylok Risers This lid can handleweight up to alawn mower or small garden tractor

Handles that flip up for easy removal; factory installed gasket for a watertight seal; stainless steel screws included; Only Polylok Risers and Adapter Rings are compatible with this product. The product is currently available in stock.

Polylok Heavy DutyRiser Lids

Each of the Polylok Heavy Duty riser covers is specifically engineered to withstand larger weights and may be used with any of the Polylok risers. Corrugated pipe can also be accommodated by the 24″ Heavy Duty Cover. Each of these lids is secured in place by stainless steel screws that are provided with each lid. Specifications of the product

  • Ratings for heavy loads up to 3500 pounds have been tested. Factory-installed gasket provides a watertight seal
  • Stainless steel screws are included for assembly. Polylok Risers or an Adapter Ring are compatible with this product. Covers for 24″ corrugated or dual wall pipe are available. Availability: AVAILABLE IN STOCK
See also:  How T Opump Septic Tank? (Solution)
20′ Heavy Duty Lid ( 3017-C20) Technical Specifications24′ Heavy Duty Lid ( 3008-WEST) Technical Specifications

Do you require assistance? Please contact us toll free at 1-877-925-5132 for professional assistance.

Polylok 6′ Tall Septic Tank Riser

Polylok septic tank risers are among the most durable products available on the market today. They may be stacked, which provides a great deal of versatility when it comes to raising the grade of the entryway. Each riser is secured in place with the stainless steel screws that are supplied with the purchase. Specifications of the product

  • Structures with heavy-duty structural reinforcements for increased strength
  • Factory-installed gasket provides a watertight seal
  • Stainless steel screws are included for assembly. Polylok Risers and Adapter Rings are the only ones that will fit. Availability: IN STOCK
Watch MoreAbout Polylok Risers All Polylok Risers are stackable giving greatflexiblity when bringing your access to grade!Stainless Steel screws included for attachment

We provide the greatest collection of septic goods on the internet, with over 850 different options.

Polylok 12′ Tall Septic Tank Riser

Polylok septic tank risers are among the most durable products available on the market today. They may be stacked, which provides a great deal of versatility when it comes to raising the grade of the entryway. Each riser is secured in place with the stainless steel screws that are supplied with the purchase. Specifications of the product

  • Among the most durable septic tank risers available today, Polylok is one of the best options. They may be stacked, which provides a great deal of versatility when it comes to raising the grade of the entry way. With the provided stainless steel screws, each riser can be locked into place and secured. Details about the product
Watch MoreAbout Polylok Risers All Polylok Risers are stackable giving greatflexiblity when bringing your access to grade!Stainless Steel screws included for attachment

Put your trust in the professionals with more than 20 years of expertise in the wastewater business.

Polylok 2′ TALL Grade Riser

To finish adjusting your access point to the final slope, use the Polylok 2″ Tall Grade Risers to complete the job. This object can be placed at any point along the riser stacking hierarchy. When in use, the grade riser locks into place and is secured with stainless steel screws that are provided. THIS ITEM WILL NOT BE COMPATIBLE WITH THE SAFETY SCREEN! Specifications of the product

  • Available in two diameters: 20″ and 24″. Factory-installed gasket provides a watertight seal
  • Stainless steel screws are included for assembly. Only works with Polylok Risers. Availability: AVAILABLE IN STOCK
Watch MoreAbout Polylok Risers All Polylok Risers are stackable giving greatflexiblity when bringing your access to grade!Stainless Steel screws included for attachment

To make an order, you may purchase online at any time or phone us toll free at 1-877-925-5132.

Polylok Safety Screen

The Polylok safety screen serves as a backup layer of protection in the event that the riser cover is broken or removed accidentally. The screen is compatible with both the 6″ and 12″ tall risers. Specifications of the product

  • With a built-in handle for simple removal
  • Tested at a density of 250 pounds per square foot Screws made of stainless steel are included. It is compatible with both the Poylok 6″ and 12″ Risers. Availability: AVAILABLE IN STOCK
Watch MoreAbout Polylok Risers PLEASE NOTE: SAFETY SCREENDOES NOT FIT 24′ RISER PAN

Do you require assistance? Please contact us toll free at 1-877-925-5132 for professional assistance.

Adapter Ring Installation KitHighly Recommened

It includes everything you need to quickly and easily install and attach the Polylok Adapter ring to your septic tank, including all of the necessary hardware. Included in the Anchor Kit is:

  • The following items are available: (1) 20-foot roll of Butyl Sealant
  • (8) Concrete Wedge Anchors
  • And (1) Masonry Drill Bit

Put your trust in the professionals with more than 20 years of expertise in the wastewater business.

Butyl Sealant Rope

The butyl sealant rope is used to create a watertight seal between the adapter ring and the septic tank. The butyl seal rope is 5/16′ round and comes on a 20 foot roll.Availability: IN STOCK

Take advantage of professionals with more than 20 years of expertise in the wastewater sector.

Handle For PreCast Concrete Lid

Extremely strong, non-corrosive HDPE ribbed handle forprecastconcrete septic tank and distribution box lids. Also acceptssnap-onwarning placards.

Septic Tank Covers and Risers Elk River MN

The majority of Elk RiverMN septic systems are designed with an underground septic tank as standard equipment. AManhole Coveror aLidis utilized to get access to the septic tank for the purposes of cleaning and inspection. Depending on the soil type, the tank may be sunk anywhere from 8″ to 2 feet below ground level. The manhole cover on an older model septic system is typically positioned around one foot below ground level. Installing a Septic Tank Access Riser makes it simpler to get access to the tank without jeopardizing the tank’s security.

that new septic systems be installed with the manhole cover at ground level.

Manhole Cover Access Risers

It is considerably more convenient to do regular septic tank maintenance when the lid is easily accessible. A smaller cleaning bill from your local septic contractor will result as a result of this. Having to dig up the manhole cover every time the tank has to be drained out leads in extra time and money being spent on the project. CSI Custom Septic, Inc. can install a Manhole Cover Access Riser on your property. Risers are available in a number of various styles and made of a range of different materials.

Septic Tank Manhole Extension Risers

As long as they maintain the tank sealed up properly, septic tank covers and extension risers may be fashioned of a variety of various types of materials. It is critical to have a good waterproof seal on the tank to prevent runoff from entering the tank. It is possible to make the tank lid safe, secure, and free of odors if it is done correctly. Installing an Access or Extension Riser is a cost-effective solution for homeowners in Elk River who have septic systems on their property.

  • Steel and concrete manhole covers
  • Polyloc Septic Tank Lids
  • Metal adjustment rings
  • Tuf-Tite LidsExtenders
  • Plastic access rims
  • Concrete rims
  • Polyethylene lids risers
  • Decorative rock covering

MN Septic System Inspections and Installation

When CSI Custom Septic, Inc. installs Septic Tank Covers, Risers, Lids, or Extenders, you never have to be concerned about the workmanship or quality of the product. Residents in the Elk River MN region may benefit from our team’s extensive knowledge and expertise in the field of residential septic systems. Individual sewage systems are designed, installed, repaired, and inspected in a variety of cities around Minnesota. To get a free, no-obligation estimate, give us a call right now! The number to call for professional installation of septic tanks, manhole covers, lids, and access risers in Elk River MN is (763) 218-4769, and the company is CSI Custom Septic, Inc.

Septic Tank Riser Kits

Prices include free delivery within the continental United States. Our Septic Tank Riser Kits are proudly made in the United States of America. Orders placed before 12 p.m.

EST are dispatched the same day through UPS ground. Dimensions of the Septic Tank Riser – Click to enlarge. Watch this video to see how simple it is to install an Aero-Stream Septic Tank Riser! Parts and pieces that make up our Septic Tank Risers Features of our Septic Tank Risers are as follows:

  • Ready to install – no need to cut anything on the job site
  • Lid with a low profile
  • Safety Barrier that is built in
  • Installation is simple. Fits all tanks with a flat top
  • The installation of a Septic System Saver is made easier by this device.

Purchase the safest, highest-quality Septic Tank Riser available on the market! We’ve thrown in our Premium Low Profile lid at no extra charge. Coverage with a Low-Profile Finish

  • The low-profile lid raises the riser by only 0.5 inch. HDPE structural foam in a green color
  • Almost flush with the surrounding yard
  • Maintenance and mowing will be less difficult.

It takes only 0.5′′ to raise the lid from its low profile; a high-density polyethylene structural foam that is environmentally friendly. On a par with the rest of the yard, in fact; Maintenance and mowing will be less difficult to complete.

  • A safety barrier has been installed beneath the septic tank riser lid. Tank can be maintained without having to remove it. It is possible to remove it for servicing the baffles. Fits all shapes of holes, including round, square, rectangular, and other shapes
  • A patent application is pending. HDPE material that has been 100 percent recycled

The suggested retail price is $219.00.

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Contains a lid and a 7-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

MSRP: $248.0010′′ Septic Riser (MSRP $248.00) (AS-R10)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 10′′ riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

MSRP: $283.0013′′ Septic Riser (MSRP: $283.00) (AS-R13)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 13-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Typical Retail Price: $312.0016-Inch Septic Riser (AS-R16)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Contains a lid and a 16-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

MSRP: $343.0019′′ Septic Riser (MSRP: $343.0019′′ Septic Riser) (AS-R19)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 19-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Septic Riser with an MSRP of $365.0023′′ (AS-R23)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 23-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

The MSRP for this item is $383.0026′′ Septic Riser (AS-R26)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 26-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Septic Riser with an MSRP of $413.0029′′ (AS-R29)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 29-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

MSRP: $443.0032′′ Septic Riser (MSRP $443.0032′′ Septic Riser (AS-R32)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 32-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

enables maintenance to be performed more easily by elevating the tank entrance to the ground level With an inner diameter of 23-1/2 inches, the plastic adapter ring measures 30-1/4 by 30-1/4 inches. Covers all entrance forms, including round, square, and rectangular openings, amongst other things; Contains a lid as well as a 32-inch riser pipe Installation is straightforward, and the package includes all necessary hardware and sealants.

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 35-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.
See also:  How To Unclog Pipe From Septic Tank To Leach Field? (Solution)

MSRP: $489.0038′′ Septic Riser (MSRP: $489.0038′′ Septic Riser) (AS-R38)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 38-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Septic Riser with an MSRP of $513.0041′′ (AS-R41)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 41-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Septic Riser with an MSRP of $572.0044′′ (AS-R44)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 44-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MSRP of $595.0047′′ Septic Riser with an MS (AS-R47)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • The set includes a cover and a 47-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

MSRP: $619.0050′′ Septic Riser, MSRP: $619.00 (AS-R50)

  • Increases the height of the tank entrance above the ground level, making maintenance easier. The plastic adapter ring is 30-1/4′′ x 30-1/4′′ and has an inner diameter of 23-1/2′′. Covers all entrance forms, including round, square, and rectangular openings, among others
  • Includes a cover as well as a 50-inch riser pipe. Installation is straightforward, and the kit includes all necessary hardware and sealants.

The suggested retail price is $207.00.

  • You supply the pipe with an inner diameter ranging from 23.5′′ to 24.5′′
  • Fits ADS 24′′ (23-1/2′′) and old ADS 24′′ inside diameter double wall corrugated pipe
  • Plastic adapter ring measures 30-1/4′′ x 30-1/4′′ with an internal diameter of 22-1/2′′
  • It can accommodate openings of various forms, including round, square, and rectangular. Included are all of the necessary hardware, sealant, and an installation instructions.

The suggested retail price is $97.00. The Riser AdapterFlange for Septic Tanks with Safety Barrier

  • ADS 24′′ (23-1/2′′) inner diameter double wall corrugated pipe and old ADS 24′′ inside diameter double wall corrugated pipe are both compatible with four (4) stainless steel screws to attach the Adapter Flange/Safety Barrier to the Riser Ring. Plastic adapter ring measures 30-1/4′′ x 30-1/4′′ with an internal diameter of 22-1/2′′
  • It can accommodate openings of various forms, including round, square, and rectangular. Instructions for installation

MSRP: $102.0024′′ Premium Low Profile Septic Tank Riser Lid (MSRP: $102.0024′′ Premium Low Profile Septic Tank Riser Lid)

  • The lid has a low profile and is only 1/2 inch high. Inside diameter double wall corrugated pipe will suit both new ADS 24′′ (23.5′′) and old ADS 24′′ inside diameter double wall corrugated pipe HDPE structural foam in a green color
  • Three square drive bits are supplied, as is a rubber gasket. Almost flush with the surrounding yard
  • The mowing and upkeep are less complicated.

The suggested retail price is $207.0024′′. A riser pipe connector for a septic tank that comes with a safety barrier kit.

  • Used with ribbed and smooth walled pipe with an ID of 24 inches
  • Inside diameter double wall corrugated pipe will suit both new ADS 24′′ (23.5′′) and old ADS 24′′ inside diameter double wall corrugated pipe current 24 inch riser is lengthened
  • Constructed of 24′′ ID plastic sewage tank riser pipe and connects it to an existing concrete or plastic septic tank riser HDPE material that has been 100 percent recycled
  • Four (4) stainless steel screws are supplied for attaching the flange to the riser pipe.

The suggested retail price is $26.00. Kit for installing a septic tank riser

  • In addition to the Install Guide, you will need 14 1/2 feet of 3/4 inch x 1 inch Butyl Sealant Rope
  • Four (4) Tapcon Anchor Screws for attaching the Adapter Flange to the Septic Tank
  • And four (4) Stainless Steel Screws for attaching the adapter Flange to the Riser Ring.

Plastic Septic Tank Riser Pipe

Septic Tank Riser Pipe is constructed of high-density polyethylene (HDPE). They will not disintegrate in the same way that concrete riser pipe does. A brand new safety barrier is offered at a significant discount. Detailed Dimensions of a Septic Tank Riser Pipe – Click to Enlarge With every septic tank riser pipe purchases, you will receive a new Septic Tank Riser Safety Barrier at a significant discount! The suggested retail price is $112.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $140.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $178.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

15-inch Septic Tank Riser Pipe (MSRP: $212.00)

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $242.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $272.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $307.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $330.00.

  • The suggested retail price is $330.00 (plus applicable taxes).

Manufacturer’s Suggested Retail Price: $330.00

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $395.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $419.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $448.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $508.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $531.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

The suggested retail price is $555.00.

  • Double wall corrugated pipe with an ID of 23 1/2 inches
  • NEW Safety Barrier incorporated

Septic Tank Maintenance

Maintenance and cleanliness:When it comes to septic tank maintenance, it’s similar to what happens when the garbage becomes too full in your home. You take it out and empty it. As a result, once your septic tank has reached capacity, it is necessary to empty it. If you have a septic tank, the usual period of time until you have to pump it is around once every three years, depending on how many people reside in your house and how large your septic tank is. In the event that you have five or more people living in your home, and depending on the size of your septic tank, you may want to consider pumping your septic tank every two years rather than every year.

  1. Flushing some items down the toilet will not function with septic systems and may result in a quicker build-up of waste or even more serious problems that will be a nuisance to deal with.
  2. There is, however, a vast spectrum of objects that should not be flushed down the toilet.
  3. Septic tanks are buried at a depth ranging from one to five feet below ground level.
  4. It lowers the tank lid to the ground, allowing you a hassle-free view of the contents.
  5. Save money on the expensive find and digging fees by using our service.
  6. We have 18-inch and 24-inch risers available, as well as a wide variety of lids to pick from.
  7. The Tank Adaptor costs $75.00.

Match The Correct Riser And Lid To The Tank To Ensure Safety And…

Receive articles, stories, and videos about septic tanks delivered directly to your email! Now is the time to sign up. Septic Tanks and More Receive Notifications We receive a constant stream of queries concerning how to install risers and, by extension, how to install the lids on those risers. One of the most prevalent themes we hear when it comes to system installation is that systems must be built with monitoring and maintenance in mind. This implies that all components must be fitted in a way that allows them to be readily reached by experts and that allows them to be repaired or replaced when necessary.

As a result, offering cost-effective service is dependent on providing quick access.

This makes the task of the service provider or inspector while examining the state of the tank, as well as the duty of the pumping contractor when the tank is full, a whole lot easier to do.

The homeowner will save money on maintenance as a result of not having to spend time identifying and digging the tank, which saves time and money.

CHOOSE THE RIGHT MATERIAL

There are several different types of rims and lids available, including concrete, polyethylene, polypropylene, polyvinyl chloride, and fiberglass. No matter what material is used, the riser and the connection to the tank or additional risers must be waterproof and resistant to root intrusion. If roots are able to get through, the structure is not waterproof! Risers should also be structurally stable, so that they do not lose their form after backfilling with concrete. In the case of concrete tanks, a riser is frequently cast into the tank during the manufacturing process.

  1. If you live in a cold area, you will benefit from using cast-in-place risers since they are less susceptible to frost heave, which causes risers linked with joints to split over the winter and impairs watertightness.
  2. The majority of what we’ve seen so far includes casting an adapter ring into the tank hole, which is advantageous because having risers cast in place might interfere with setting the tank and being in the way when the system is fitted.
  3. It is critical to follow the manufacturer’s directions while applying sealants to guarantee that the building is waterproof.
  4. Watertightness is achieved by the use of mastic and other sealants.
  5. This is the standard layout for tanks that are newly constructed.
  6. As a result, an upgrade is required to bring a riser to the surface for future service convenience.

RETROFITS

Making these connections completely waterproof is a difficult task. We frequently encounter a riser that is somewhat bigger or of a different shape than the current aperture (round versus square), mostly because it is the most readily available option on the market. It is then placed over the top of the tank lid in an attempt to mortar them into place, before being removed. They are readily loosened, and when the tank is opened, it is discovered that water and soil have been introduced into the tank through this connector.

The good news is that new items to assist with this issue are being accessible all of the time, which is encouraging.

Most polyethylene and fiberglass tanks will have risers incorporated into them at the time of production, unless otherwise specified.

To keep children and animals out, lids must be built of sturdy materials with connections that are both water- and air-tight, and they must be kept closed when not in use.

Homeowners may also object to lids that are visible on the surface of the water. In these instances, putting a tiny metal marker to the top of the container addresses the difficulty of locating it. Service providers can utilize a metal detector to find the tank entry point in a short amount of time.

MORE SAFETY TIPS

We believe it is preferable to have the lids raised a couple of inches above the surface of the water to make it easier for the service provider to reach the water. It is critical, however, that the lid is secured with nonstandard bolts or screws to ensure that minors, in particular, are unable to open it. Every year, we receive a number of instances of youngsters falling into septic tanks and being gravely hurt or killed because the lid has not been properly affixed to the riser, as is often the case.

These devices are available for purchase separately.

Purchasing this insurance coverage and upgrading their system may prove to be a wise investment.

In most cases, this results in riser deformation and a lack of watertightness, as well as the creation of a dangerous access problem.

Leave a Comment

Your email address will not be published. Required fields are marked *