Where Can I Get A 1250 Gallon Septic Tank Near Me? (Solution found)

How do you repair a septic tank?

  • To repair a leach field, restore the septic tank to reduce the load on it, decrease the amount of waste put in the tank, avoid excessive wetting of the soil close to the field, and make a separate drain field for wash water. In addition, drain water from the septic tank, and remove any debris from the pipelines of the field regularly.

How often should a 1250 gallon septic tank be pumped?

A: As a general rule, a septic tank should be pumped and emptied every 3 to 5 years. Homes outside a city may rely on septic tanks since they don’t have access to city sewer lines.

How long does it take to fill a 1250 gallon septic tank?

On average, it takes up to 5 years for a regular, on-lot septic tank to fill up.

How long can a septic tank go without being pumped?

You can wait up to 10 years to drain your tank provided that you live alone and do not use the septic system often. You may feel like you can pump your septic tank waste less frequently to save money, but it’ll be difficult for you to know if the tank is working properly.

What are the signs that your septic tank is full?

Here are some of the most common warning signs that you have a full septic tank:

  • Your Drains Are Taking Forever.
  • Standing Water Over Your Septic Tank.
  • Bad Smells Coming From Your Yard.
  • You Hear Gurgling Water.
  • You Have A Sewage Backup.
  • How often should you empty your septic tank?

Can a septic tank be too big?

A septic tank that is too big will not run well without the proper volume of wastewater running through it. If your septic tank is too big for your house, there wouldn’t be sufficient collected liquid required to produce the bacteria, which helps break down the solid waste in the septic tank.

How much does it cost to pump a septic tank?

How much does it cost to pump out a septic tank? The average cost is $300, but can run up to $500, depending on your location. The tank should be pumped out every three to five years.

How do I clean my septic tank naturally?

You can mix about a 1/4 cup of baking soda with 1/2 cup of vinegar and 2 tablespoons lemon to make your own natural cleaning agent. The baking soda will fizz up to help get the dirt and grime in your tub and drains. It’s a great cleaner and your septic system will thank you!

How often should a 1200 gallon septic tank be pumped?

How Often Do You Need To Have Your Septic Tank Pumped? As a general guideline, a septic tank needs to be pumped and emptied every 3 to 5 years. Houses outside a city may count on sewage-disposal tanks since they do not have access to city sewer lines.

How often does a 1500 gallon septic tank need to be pumped?

Family of 5, 1000-gallon tank – pump every 2 years. Family of 5, 1500-gallon tank – pump every 3.5 years.

Does shower water go into septic tank?

From your house to the tank: Most, but not all, septic systems operate via gravity to the septic tank. Each time a toilet is flushed, water is turned on or you take a shower, the water and waste flows via gravity through the plumbing system in your house and ends up in the septic tank.

Buy 1,250 Gal. Plastic Septic Tank

Tank / Capacity Length Width Height Size Compartments Part From Price
1250 Gallon Septic Tank 118″ 58″ 72″ 118″ L 58″ W 72″ H 1 AST-1250-1 IA $2,159
1250 Gallon Septic Tank 118″ 58″ 72″ 118″ L 58″ W 72″ H 2 AST-1250-2 IA $2,159
1250 Gallon Low Profile Septic Tank 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 43503 MN, OH, OK, UT, WA $2,279
1250 Gallon Septic Tank 116″ 55″ 70″ 116″ L 55″ W 70″ H 1 41741 MN, NY, OH, OK, UT, WA $2,136
1250 Gallon Septic Tank 116″ 55″ 70″ 116″ L 55″ W 70″ H 2 41743 MN, NY, OH, OK, UT, WA $2,283
1250 Gallon Septic Tank 116″ 55″ 70″ 116″ L 55″ W 70″ H 2 41744 CA $2,283
1250 Gallon Low Profile Septic Tank – FL Approved 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 43532 FL $2,921
1250 Gallon Low Profile Septic Tank 157″ 60″ 51″ 157″ L 60″ W 51″ H 1 43519 MN, OH, OK, UT, WA $2,135
1250 Gallon Low Profile Septic Tank – Intended For Use In IL 157″ 60″ 51″ 157″ L 60″ W 51″ H 1 43539 OH $2,135
1250 Gallon Low Profile Septic Tank – Intended For Use In IL 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 43542 OH $2,279
1250 Gallon Low Profile Septic Tank 157″ 60″ 51″ 157″ L 60″ W 51″ H 1 43544 GA $2,135
1250 Gallon Low Profile Septic Tank 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 43545 GA $2,279
1250 Gallon Low Profile Septic Tank – IAPMO Approved 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 44483 CA $2,418
1250 Gallon Low Profile Septic Tank – NC/SC Approved 157″ 60″ 51″ 157″ L 60″ W 51″ H 2 43511 GA $2,279

1250 Gallon Septic Tanks: Precast Concrete

Precast concrete tanks, such as our 1250-gallon tank, are a suitable traditional septic tank size for a four-bedroom home. New Hampshire concrete tank sizes are most commonly found in this configuration.

1250 Gallon Septic Tank

Each 1,250 gallon septic tank that A.J. Foss creates from precast concrete is intended to hold up to 1,250 gallons of liquid waste, which is the maximum amount of liquid waste that can be contained in one tank. Our tanks meet or exceed all of the ASTM C 1227NPCA best-practice criteria. This sort of mid-seam styleconcrete septic tankallows the pipe from the home to be routed to either of the tank’s side or center intake locations. The same choice is available for the tank’s outlet drainage pipe, which may be extended out to the leach field from either the tank’s side or middle outlet drainage pipe.

If you have any questions regarding the broad selection of sizes and styles of one and two-compartment septic tanks and accessories that we produce at our state-of-the-art plant, please contact one of our knowledgeable septic specialists at A.J Foss.

1250 Gallon Septic Tank Details
Tank dimensions 8’ Long5’8” wide6’ Tall
Number of bedrooms supported Up to 4 – Minimum size now required
Pre-assembled Yes
Ideal for high water table No but our 1500 gallon monolithic septic tank is.
Average retail cost $1250
Number of tank lids (covers) 2
Can come in traffic rated (H20) capacity Yes
Concrete strength 5,000 PSI
What are its gallons per vertical inch 23
Weight 11,500 lbs.
Fiber reinforced Yes
Number of inlets boots (Up to schedule 40pipe can slide through) 3
Height of inlet from bottom of tank to bottom of pipe 63”
Number of outlets boots (Up to schedule 40 pipe can slide through) 3
Height of outlet from bottom of tank to bottom of pipe 60”
Required height of inlet baffle (20% of liquid level) 12”
Required height of outlet baffle (40% of liquid level) 23”

Septic tank made of precast concrete and fitted with plastic risers for a water-tight seal. It is brand new and never used.

Frequently Asked Questions

  • Systems that are more traditional in nature include Concrete Chamber Systems (for anaerobic systems), Mound Septic Systems (an above-ground septic system with a drain field mound), Sand Mound or Sand Filter Septic System, Gravity Septic System (needs a gradual slope), and others.

What is the average cost of a 1250 gallon precast concrete septic tank?

Answer:In terms of septic tank prices, the typical retail price for a 1,250-gallon system is $1250 on the open market. The most important factors that influence the average price of residential septic tanks are the size of the house and the amount of water used per day (or the consistency of the flow of wastewater), which influences the gallons capacity of water flow dependent on the amount of water consumed. A five- or six-bedroom house will require at least a 1,500 gallon tank, if not a bigger tank; in contrast, a two- or three-bedroom house will require a smaller tank and, as a result, cheaper tank pricing.

What affects the average price of septic system installation by professional installers?

The following are some of the factors that might influence the typical price of septic tank installation costs:

  • Choosing the right septic tank (for example, precast concrete vs lighter fiberglass tanks)
  • A drainage field or absorption field of a certain size (which might have an impact on labor expenses)
  • It is necessary to consider the presence of adjacent water sources (which may need the conversion of traditional septic system designs to alternative systems). Norweco Singlair Wastewater Treatment Systems, for example, are aerobic systems that employ aerobic microorganisms to treat waste water.

Soil testing to establish the soil conditions is an additional cost of installation issue to take into consideration. Get in touch with skilled specialists to acquire reliable pricing estimates for your unique tank requirements.

What is the most common septic tank size?

In New Hampshire, the septic tank with a capacity of 1250 gallons is used. Among septic designers, it is the tank that is most frequently specified and used. It is the smallest tank permitted by the New Hampshire Department of Environmental Services, and it may accommodate a dwelling with up to four bedrooms. Extra bedrooms would require an additional 250 gallons per bedroom. As a result, a septic tank of 1500 gallons would be required for a five-bedroom house.

Can you drive over a 1250 gallon size septic tank?

When it comes to driving cars or heavy machinery over a tank, the design rating is what decides whether you can. A.J. Foss makes three different types of septic tank installations: H-10 is designed for pedestrian activity and has a live load of 300 pounds per square foot plus a burial depth of 3 feet.

HD is intended for burial depths up to 5 feet. The H-20 rating is for vehicular drive-over traffic up to a maximum burial depth of 6′ in the ground.

Is it ideal for high water table areas?

Answer:Our regular 1,250-gallon septic tank is constructed in two parts, with the seam running along the centre of the tank. Because the seam is located at the very top of the septic tank, our 1250 gallon monolithic septic tank is perfect for use in areas with a high water table or near bodies of water. Because the liquid sits underneath the cover, there is no risk of anything leaking in or out.

How much does a 1250 gallon concrete septic tank weigh?

In response to your question, our 1,250-gallon concrete septic tanks weigh about 11,500 pounds. Based on the specifications, wall thickness, floortop thickness, and rebar reinforcement used by different precast manufacturers, weights might vary somewhat.

How many bedrooms does a 1250 gallon septic tank support?

According to the state of New Hampshire, a 1250 gallon tank can maintain a four-bedroom house. Since the regulations were updated in 2012, it is the smallest tank size that may be specified on new designs for the first time.

  • A 1250 gallon septic tank is utilized in systems with up to four bedrooms. The most often encountered tank size in New Hampshire
  • The smallest tank we propose for use as a septic tank is the following: It is shipped pre-assembled to make installation as simple as possible

Why are steel tanks or plastic tanks generally not recommended?

Because it is durable, practical, and long-lasting, precast concrete continues to be the most popular material for septic tanks and systems. Plastic tanks and fiberglass tanks, which are made of lighter materials than concrete and appear to be a more cost-effective choice, might be damaged during the installation process. In the case of structural damage to a plastic or fiberglass septic tank, the tank may need to be completely replaced. Septic tanks made of plastic are only recommended for use with alternative sewage systems, such as Norweco Singulair aerobic septic systems, which use oxygen-loving bacteria in conjunction with an aerator to break down solid waste and produce cleaner wastewater effluent that can be discharged to a drain field.

Features/Details*

  • A 1250 gallon septic tank is utilized in systems with up to four bedrooms. The most often encountered tank size in New Hampshire
  • The smallest tank we propose for use as a septic tank is the following: It is shipped pre-assembled to make installation as simple as possible

In installations with up to four bedrooms, a 1250 gallon septic tank is used. A standard size for an NH storage tank is 40 cubic yards. Septic tanks should be no larger than the following dimensions: height, width, depth, and capacity. To make installation easier, it is shipped pre-assembled.

  • The following sizes are available: Precast Concrete Septic Tank – 1000 Gallon
  • Precast Concrete Septic Tank – 1250 Gallons Monolithic
  • Precast Concrete Septic Tank – 1500 Gallons Monolithic
  • Precast Concrete Septic Tank – 1600 Gallons
  • Precast Concrete Septic Tank – 1600 Gallons Monolithic
  • Precast Concrete Septic Tank – 2000 Gallons
  • Precast Concrete Septic Tank – 2000 Gallons Monolithic
  • Precast Concrete Septic Tank – 2000 G Precast Concrete Septic Tank – 1025/275 Gallons
  • Precast Concrete Septic Tank – 1250/350 Gallons
  • Precast Concrete Septic Tank – 1250/350 Gallons Monolithic
  • Precast Concrete Septic Tank – 1250/500 Gallons
  • Precast Concrete Septic Tank – 1500/500 Gallons Monolithic
See also:  Who Do I Contact To Report A Business'S Leaking Septic Tank? (Perfect answer)

a little about the author: The Andrew J. Foss, Inc. precast concrete firm was founded by my father in 1963 when he was just 19 years old. My precast education began at a very young age for myself. Everything I know about producing high-quality precast concrete goods, from septic tanks to concrete headwalls, was passed down to me by him. He also taught me that in order to be successful in business, you must provide a superior product and treat your customers the way you would like to be treated yourself.

Septic Tanks Arkansas

Arkansas Approval Requirement: 1000 Gallon Minimum Capacity
Name Size Part Number Price Ships From
200 Gallon Plastic Septic Pump Tank (43745) 47″ dia x 56″H N-43745 $519.99 MN, OK, UT, OH
300 Gallon Sphere Pump Tank (41319)Ships In 48 Hours 54″ dia x 54″H N-41319 $723.99 MN, OH, GA, NY, WA, CA, UT, OK
300 Gallon Plastic Septic Pump Tank 54″dia. x 56″H A-AST-0300-1 $720.26 IA
500 Gallon Sphere-Pump/Dosing Tank (40785) 64″ dia. x 67″H N-40785 $989.00 MN, OH, WA, CA, OK, UT
500 Gallon Plastic Septic Tank – 1 Compartment 101″ L x 51″ W x 47″ H N-41320 $1,061.00 MN, GA, UT, WA
500 Gallon Plastic Septic Pump Tank 63″dia. x 74″H A-AST-0500-1 $998.31 IA
1000 Gallon Plastic Septic Tank – 1 Compartment 102″ L x 60″ W x 58″ H N-41718 $1,785.00 MN, GA, UT, NY, WA, OH, OK
1000 Gallon Bruiser Septic Tank – 1 Compartment 102″ L x 60″ W x 58″ H N-41734 $2,213.00 MN, GA, UT, NY, WA, OH, OK
1000 Gallon Plastic Septic Tank – 2 Compartment 102″ L x 60″ W x 58″ H N-41720 $1,916.00 GA, NY, WA, OH, CA, MN, OK, UT
1250 Gallon Bruiser Septic Tank – 1 Compartment 116″ L x 55″ W x 70″ H N-41752 $2,791.00 MN, UT, NY, WA, OH, OK
1250 Gallon Plastic Septic Tank – 1 Compartment 116″ L x 55″ W x 70″ H N-41741 $2,067.00 MN, UT, NY, WA, OH, OK
1500 Gallon Plastic Septic Tank – 1 Compartment 135″ L x 55″ W x 70″ H N-41758 $2,675.00 MN, UT, NY, OH
1500 Gallon Bruiser Septic Tank – 1 Compartment 133″ L x 55″ W x 70″ H N-41771 $3,342.00 MN, GA, UT, NY, WA, OH, OK
1500 Gallon 2 Compartment Plastic Septic Tank (Preplumbed) 157″ L x 69″ W x 51″ H N-43502 $2,903.99 OK, WA
1500 Gallon 2 Compartment Plastic Septic Tank (Loose Plumbing) 157″ L x 69″ W x 51″ H N-43504 $2,725.00 MN, OK, NY, WA, OH, UT, GA, CA, CA
1500 Gallon 1 Compartment Plastic Septic Tank (Preplumbed) 157″ L x 69″ W x 51″ H N-43498 $2,880.00 OK, WA
1500 Gallon 1 Compartment Plastic Septic Tank (Loose Plumbing) 157″ L x 69″ W x 51″ H N-43518 $2,547.00 MN, OK, NY, WA, OH, UT, GA
2000 Gallon Underground Holding Tank 126″ L x 98″W x 51″H N-44593 $4,493.00 MN, OH, OK
2500 Gallon Underground Holding Tank 159″L x 99″W x 51″H N-44079 $5,177.99 CA, MN, OK
2600 Gallon Underground Holding Tank 155″ L x 98″W x 51″H N-43770 $5,910.22 MN
2650 Gallon Underground Holding Tank 155″ L x 98″W x 81″H N-43771 $6,394.00 MN
3525 Gallon Underground Holding Tank 211″ L x 102″ W x 51″ H N-44390 $8,437.99 TX, MN, CA
Across the United States and Canada there are a number of health code requirements that our tanks must meet.These codes are regulated by the state, county or province where you are located.To aid you in determining which tank you need, please consult with your local health department.

1250 Gallon Plastic Septic Tank – 2 Compartment

  • Pre-plumbed with PVC tees and septic adapters already fitted

Important Note: Tank must be left 1/4 full at all times including installation.

Part IAPMO Ships from
41743 No MN, OH, OK, UT, NY, WA
41744 Yes CA

Disclaimer: This tank is intended for usage below ground only.

State RequirementsApprovals

Our tanks must comply with a variety of health code standards that are in place across the United States.

These codes are governed by the state or county in which you live, depending on your location. Please speak with your local health agency for assistance in choosing the tank you require.

Septic Tank Standards:

  • Tank that has been rotationally molded into a single component that is seamless and waterproof
  • Neither soil chemicals nor sewage gases have an effect on polyethylene. Tanks made of polyethylene will not rust or corrode. Strict quality standards guarantee that the septic tank is safe for the environment. Connections to the plumbing system according to Schedule 40
  • Standard plumbing is something that all area installers or professionals are familiar with. Extensions for the risers are not included. Excellent shipping item that is virtually unbreakable.

Frequently Asked Septic Tank Questions

  • If you ask the question, no, you cannot place the plastic septic tank beneath a driveway since it is not authorized, and doing so will invalidate the guarantee. Keep tanks out of the line of heavy and vehicle traffic regions, and don’t put them beneath driveways. If you’re looking for bedding or backfill, a sand/gravel mixture (sometimes known as “pea gravel”) is a good option. (Please refer to the installation instructions above.) 3. Is it possible to utilize a septic tank above ground? Underground plastic septic tanks are intended for use solely below ground. They are not intended for above ground usage. The use of above-ground storage tanks may result in the tank’s distortion and degradation. When compared to underground storage tanks, it is significantly more cost-effective to employ an above-ground storage tank that has been particularly constructed for above-ground uses. 4. Can hot water be held in plastic septic tanks? Yes, but only if the water temperature in the tank does not exceed 100 degrees Fahrenheit. The maximum storage temperature for polyethylene storage tanks is 120 degrees Fahrenheit. Containments with a temperature greater than 120 degrees Fahrenheit, even for a short period of time, might degrade the structural integrity of the tank and making it more prone to deformation and collapse
  • 5. How do you gain access to underground plastic septic tanks? Each underground plastic septic tank is supplied with manhole access hatches, which allow you to gain access to the tank (1 or 2 depending on tank). Additionally, risers can be placed to the top of the tank to provide for access from the ground level. A riser would save you from having to dig up the dirt above the manway in order to get access
  • Otherwise, 6. Is it possible to pick up a plastic septic tank in the area? In most circumstances, yes. You must place an order in advance in order to pick up a plastic septic tank and save money on shipping. When you are notified that your tank is ready for pickup, Plastic-mart will offer you with a six-digit trip number that will allow you to come in and pick up your tank Monday through Friday from 8:30 a.m. to 2:00 p.m. Plastic-mart and the local producers are grateful for the chance to provide local pick-up as well as the collaboration necessary to ensure that the process is as efficient as possible.

Plastic Septic Tanks – Two Compartments

Ace Septic TanksAce Roto-Mold septic tanks are stronger, easier to install, and less costly than old-fashioned concrete septic tanks- yet they still offer the quality construction and safety you expect. Manufactured from high-density polyethylene with U.V. inhibitors, Ace Roto-Mold tanks utilize a horizontal flow designed for below ground installations up to 36 inches. Ace Tanks are IAPMO approved and have passed strenuous stress tests. Each tank carries an individual serial code and is fully document from date of manufacture.Ace Roto-Mold septic tanks are designed and manufactured with rigorous quality controls. The trapezoidal deep-rib design and interior baffle system make Ace Tanks the industry choice. Only Ace tanks feature a custom-molded gasket in the lid. Manufactured from extruded Nitrile rubber, the gasket snaps into the lid and ensures a watertight seal. Our exclusive lid design locks in place with nylon ties, eliminating the need for metal fasteners that can corrode and fail.Ace’s unique tank baffle system slows the flow of wastewater and directs it to the middle of the tank so wastewater can separate from solids. An outlet baffles allows the partially treated liquids to flow out for further treatment. Advantages of Ace’s baffle design include added strength, versatility, and ease of installation.Septic tanks are available in one-compartment and two-compartment designs and are manufactured for containment of liquids up to 1.7 specific gravity.Ace Septic / Cistern Tank AccessoriesRemember to order your state specific internal plumbing kit. Links:Septic Tank Product Description, Function and ServiceSeptic Tank Installation ProceduresSpherical Septic Tank Installation ProceduresSeptic Tank Divider Installation Procedures

Norwesco Septic Tanks300 + 500 Gallon Spheres may be used as Septic Holding Tanks (Pump Out).SeeUnderground Water Tanksfor others availablefor Septic Holding Tanks.The world’s leading manufacturer of polyethylene tanks, NORWESCO has been producing polyethylene septic tanks since 1980. With that kind of experience, NORWESCO offers you proven products that you can count on for years of dependable, trouble-free service.For septic system replacement and new home construction, NORWESCO‘s polyethylene septic tanks are designed for durability and quick, easy installation. Any NORWESCO septic tank can be transported to the job site in a pickup truck and carried by just two people. That enables you to install the tank on your schedule.All NORWESCO septic tanks are manufactured by means of the rotational molding process, which produces a one-piece, seamless, watertight tank. Polyethylene is unaffected by soil chemicals and by the chemicals and gases present in sewage, so NORWESCO septic tanks will not rust or corrode and require no additional coatings as other tanks do. NORWESCO’s strict quality guidelines ensure an environmentally safe septic tank.NORWESCO septic tanks come equipped with manhole covers and detailed installation procedures. Manhole extensions and lid/riser combinations are available to bring tank access to grade and to meet code specifications. The 750, 1000, 1250 and 1500 gallon sizes are available in both one and two compartment configurations.NORWESCO septic tanks are for BELOW GROUND USE ONLY. Using the tanks above ground may result in deformation of the tank. It is far more cost-effective to utilize one of NORWESCO’s above ground tanks that are specifically designed for above ground use and applications.The tanks described and shown on this page cannot be used as pump tanks and must be kept full at all times.PRE-PLUMBING: All of our NORWESCO septic tanks that are 750 working gallons andabove are “pre-plumbed” with PVC inlet and outlet assemblies. Assemblies andtheir components are made of either SDR35 or SCH40 PVC depending on state orlocal code requirements. All assemblies are sized according to code requirementsas well. Finally, an EPDM gasket is placed between the “T” assembly and thetank wall to assure watertightness. NORWESCO septic tanks will arrive to youready for installation.WATERTIGHT DOMED LIDS: All septic tanks manufactured at all facilities, are equipped with a watertight domed lid. This domed lid is significantly stronger than previous lids we have offered. When leaving our factory, the lid(s) will be attached to the tank with stainless steel screws and come standard with a foamed, polyethylene gasket between the lid and the tank. This gasket provides a watertight seal at the lid area.MANHOLE EXTENSIONS AND LID/RISER COMBINATIONS: Again, at all facilities, the notches in the manhole area(s) of the tank have been removed as the “interruption” in the manhole, or circle, weakens that area. The lugs on the accessories have also been removed. See tank accessories for more information on the accessory items.NORWESCO septic tanks are backed by a full three-year warranty and have been certified by state and local health departments from coast to coast. Where applicable, NORWESCO septic tanks have been certified by both IAPMO and CSA.Across the United States and Canada, there are certain health code requirements that our tanks must meet. These codes are regulated by the state, county or province.Click here for Septic Tanks in HawaiiTank Depot Tanks Light Weight – Durable – Easy to Install

What size of septic tank do I need?

Probably one of the last things on your mind when you are constructing a new house is the location of your septic system. After all, shopping for tanks isn’t nearly as entertaining as shopping for cabinetry, appliances, and floor coverings. Although you would never brag about it, your guests will be aware if you do not have the proper septic tank placed in your home or business.

septic tanks for new home construction

The exact size of the septic tank is determined mostly by the square footage of the house and the number of people who will be living in it. The majority of home septic tanks have capacities ranging from 750 to 1,250 gallons. A 1000 gallon tank will most likely be required for a typical 3-bedroom home that is smaller than 2500 square feet in size. Of course, all of this is dependent on the number of people who live in the house as well as the amount of water and waste that will be disposed of through the plumbing system.

For the most accurate assessment of your septic tank needs, you should speak with an experienced and trustworthy sewer business representative.

planning your drainfield

This is mostly determined by the square footage of the house and the number of people that will be living in it, as well as other factors. A typical household septic tank holds between 750 and 1,250 gallons of water. Typically, a 1000 gallon tank will be required for a three-bedroom home that is less than 2500 square feet in size. It goes without saying that the amount of water and garbage that is placed into the system is directly proportional to the number of people who live in the residence.

A reputable septic firm is the most dependable source for determining the appropriate size septic tank for your home.

  • Vehicles should not be allowed on or around the drainfield. Planting trees or anything else with deep roots along the bed of the drain field is not recommended. The roots jam the pipes on a regular basis. Downspouts and sump pumps should not be discharged into the septic system. Do not tamper with or change natural drainage features without first researching and evaluating the consequences of your actions on the drainage field. Do not construct extensions on top of the drain field or cover it with concrete, asphalt, or other materials. Create easy access to your septic tank cover by placing it near the entrance. Easy maintenance and inspection are made possible as a result. To aid with evaporation and erosion prevention, plant grass in the area.

a home addition may mean a new septic tank

Do not make any big additions or renovations to your house or company until you have had the size of your septic system assessed. If you want to build a house addition that is more than 10% of your total floor space, increases the number of rooms, or necessitates the installation of new plumbing, you will almost certainly need to expand your septic tank.

  • For a home addition that will result in increased use of your septic system, your local health department will require a letter from you that has been signed and authorized by a representative of your local health department confirming that your new septic system is capable of accommodating the increase in wastewater. It is not recommended that you replace your septic system without the assistance of a certified and competent contractor.

how to maintain your new septic system

Septic tank cleaning and septic tank pumping services are provided by Norway Septic Inc., a service-oriented company devoted to delivering outstanding septic tank cleaning and septic tank pumping services to households and business owners throughout the Michiana area.

“We take great delight in finishing the task that others have left unfinished.” “They pump, we clean!” says our company’s motto. Septic systems are something we are familiar with from our 40 years of expertise, and we propose the following:

  • Make use of the services of a qualified specialist to develop a maintenance strategy. Make an appointment for an annual examination of your septic system. Utilize the services of an effluent filter to limit the amount of particles that exit the tank, so extending the life of your septic system. Waste items should be disposed of properly, and energy-efficient appliances should be used. Make sure you get your septic system professionally cleaned every 2 to 3 years, or more frequently if necessary, by an experienced and qualified expert
  • If you have any reason to believe that there is an issue with your system, contact a professional. It is far preferable to catch anything early than than pay the price later. Maintain a record of all septic system repairs, inspections, and other activities

common septic questions

Here are some of the most frequently asked questions by our septic customers.

How do I determine the size of my septic tank?

If you have a rectangular tank, multiply the inner height by the length to get the overall height of the tank. In order to find out how many gallons your septic tank contains, divide the number by.1337.1337

How many bedrooms does a 500-gallon septic tank support?

The exact size of the septic tank is determined mostly by the square footage of the house and the number of people who will be living in it. The majority of home septic tanks have capacities ranging from 750 to 1,250 gallons. A 1000 gallon tank will most likely be required for a typical 3-bedroom home that is smaller than 2500 square feet in size.

How deep in the ground is a septic tank?

This is mostly determined by the square footage of the house and the number of people that will be living in it, as well as other factors. A typical household septic tank holds between 750 and 1,250 gallons of water. Typically, a 1000 gallon tank will be required for a three-bedroom home that is less than 2500 square feet in size.

Septic Tanks

Listed below is a list of the septic tanks, chlorine contact tanks, and siphon dose tank packages thatCamden Supplyoffers, along with detailed descriptions of their features and specifications. Please call Camden Supply and chat with one of our staff if you require further information on a certain product.

Single Compartment Septic Tanks

A one-compartment steel-reinforced concrete septic tank, according to the script. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 56 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 48 inches
  • Height to center line of outflow is 45 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


600 Gallon Single Septic Tank

Specifications:

  • Overall height is 62 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of outflow is 49 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


1000 Gallon Single Septic Tank

Septic tank with a single compartment made of steel reinforced concrete (SRC). Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 96 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 8,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1250 Gallon Single Septic Tank

A one-compartment steel-reinforced concrete septic tank with the lower portion cast as a single piece so that there are no seams that come into touch with effluent. Specifications:

  • Overall height is 60 inches
  • Overall length is 117 inches
  • Overall width is 68 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,400 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psiApplications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1500 Gallon Single Septic Tank

Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 11,700 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


25003500Gallon Single Septic Holding Tanks

Single Septic Holding Tank with a capacity of 2500 gallonsSpecifications:

  • The following are the specifications for a single septic holding tank:

Single Septic Holding Tank with 35 00 Gallon CapacitySpecifications:

  • Overall height is 98 inches
  • Overall length is 144 inches
  • Overall width is 78 inches
  • Height to center line of intake is 91 inches
  • Height to center line of exit is 91 inches
  • Weight is 20,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


Dual Compartment Septic Tanks

Description:Two-compartment tank with solids separator between the first and second compartments, holding 500 gallons and 500 gallons, respectively. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 96 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1250 Gallon Dual Septic Tank

Description:Two-compartment tank with a solids separator between the first and second compartments, holding 625 gallons and 625 gallons. Specifications:

  • Overall height is 60 inches
  • Overall length is 117 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 10,700 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


1500 Gallon Dual Septic Tank

Description:Two compartment system with a capacity of 1000 gallons in the first compartment and 500 gallons in the second compartment. The dosage pump portion is usually found in the second compartment. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 11,700 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections.


Triple Compartment Septic Tanks

Description:Three-compartment system with a solids separator between the first and second compartments.

Each compartment holds 500 gallons. The dosage pump segment is usually found in the third compartment. Lower part is cast as a single piece, with no seams that come into touch with effluent or other contaminants. Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of inlet is 52 inches
  • Height to center line of exit is 49 inches
  • Weight is 12,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.Options:Plastic or concrete riser sections. Available with pre-wired pump packages, complete with alarm, floats, and pump pad, with horse powers from 1/3 to 1.5, with up to 135 feet of total head capacity.


Chlorine Contact Tanks

Specifications:

  • Overall height is 56 inches
  • Overall length is 79 inches
  • Overall width is 48 inches
  • Height to center line of inlet is 48 inches
  • Height to center line of outflow is 45 inches
  • Weight is 5,000 pounds.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.500_gallon_chlorine_contact_or_grease_interceptor.pdfDownload File


Siphon Dose Tank Packages

Specifications:

  • It measures 56 inches in height, 79 inches in length, 48 inches in width, 48 inches in height from center line of intake, 48 inches in height from center line of outlet, and 5,000 pounds in weight. It is equipped with an indoor alarm and alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.


1000 Gallon Siphon Tank Package

Specifications:

  • It measures 60 inches in height, 102 inches in length, and 67 inches in width. It measures 52 inches in height from the center line of the inlet and 52 inches in height from the center line of the outlet. It weighs 10,000 pounds. It comes with an indoor alarm and an alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

1250 Gallon Siphon Tank Package

Specifications:

  • It measures 60 inches in height, 117 inches in length, and 68 inches in width. It measures 52 inches in height from the center line of the inlet and 52 inches in height from the center line of the outlet. It weighs 10,400 pounds. It comes with an indoor alarm and an alarm float.
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

1500 Gallon Siphon Tank Package

Specifications:

  • Overall height is 60 inches
  • Overall length is 150 inches
  • Overall width is 67 inches
  • Height to center line of intake is 52 inches
  • Height to center line of exit is 52 inches
  • Weight is 13,000 pounds
  • Includes indoor alarm and alarm float
Materials of construction:Steel reinforced concrete, minimum compression strength, 4000 psi.Applications:Residential septic applications, single and multifamily dwellings.

Florida Approved Septic Tanks Archives

225 Gallon Norwesco Low Profile Plastic Septic Pump Tank Non Plumbed 43551 48″L x 48″W x 50″H 225 GA, WA $579 SPECS DWG
300 Gallon Norwesco Low Profile Plastic Septic Pump Tank Non Plumbed 43552 51″L x 51″W x 52″H 300 GA $776 SPECS DWG
300 Gallon Norwesco Plastic Septic Pump Tank – Non Plumbed 41319 54″L x 54″W x 54″H 300 UT, CA, GA, MN, NY, OH, OK, WA $764 SPECS DWG
500 Gallon Norwesco Legacy Septic Tank – Single Compartment Non Plumbed – 1MH – GT 41320 101″L x 57″W x 47″H 500 UT, GA, MN, WA $1,107 SPECS DWG
1000 Gallon Norwesco Legacy Septic Tank – Double Compartment – 2MH – GT 44474 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $1,781 SPECS DWG
1000 Gallon Plastic Septic Tank – Double Compartment – Low Profile – 2MH – GT 43517 127″L x 60″W x 51″H 1000 UT, GA, MN, NY, OH, OK, WA $1,893 SPECS DWG
1000 Gallon Norwesco Bruiser Septic Tank – Single Compartment – 2MH 41734 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $2,177 SPECS DWG
1000 Gallon Norwesco Bruiser Septic Tank – Double Compartment – 2MH 41735 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $2,300 SPECS DWG
1000 Gallon Norwesco Legacy Septic Tank – Single Compartment – 2MH – GT 44473 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $1,794 SPECS DWG
1000 Gallon Plastic Septic Tank – Single Compartment – Low Profile – 2MH – GT 42405 127″L x 60″W x 51″H 1000 UT, GA, MN, NY, OH $1,771 SPECS DWG
1000 Gallon NorwescoSeptic Tank – Single Compartment – 2MH 41718 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $1,850 SPECS DWG
1000 Gallon Norwesco Septic Tank – Double Compartment – 2MH 41720 102″L x 60″W x 63″H 1000 UT, GA, MN, NY, OH, OK, WA $1,973 SPECS DWG
1250 Gallon Plastic Septic Tank – Double Compartment – Low Profile – 2MH – GT – SI/SO 43545 157″L x 60″W x 51″H 1250 GA $2,405 SPECS DWG
1250 Gallon Plastic Septic Tank – Single Compartment – Low Profile -2MH – GT – SI/SO 43544 157″L x 60″W x 51″H 1250 GA $2,254 SPECS DWG
1500 Gallon Norwesco Legacy Septic Tank – Double Compartment – 2MH – GT 44480 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $2,728 SPECS DWG
1500 Gallon Norwesco Bruiser Septic Tank – Single Compartment – 2MH 41771 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $3,163 SPECS DWG
1500 Gallon Norwesco Bruiser Septic Tank – Double Compartment – 2MH – GT 44470 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $3,128 SPECS DWG
1500 Gallon Norwesco Bruiser Septic Tank – Single Compartment – 2MH – GT 44469 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $2,947 SPECS DWG
1500 Gallon Norwesco Septic Tank – Double Compartment – 2MH 41760 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $2,940 SPECS DWG
1500 Gallon Norwesco Legacy Septic Tank – Single Compartment – 2MH – GT 44479 135″L x 70″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $2,547 SPECS DWG
1500 Gallon Plastic Septic Tank – Double Compartment – Low Profile – 2MH – GT – SI/SO (Side in and side out) 43547 157″L x 69″W x 51″H 1500 GA $2,850 SPECS DWG
1500 Gallon Plastic Septic Tank – Single Compartment – Low Profile – 2MH – GT – SI/SO 43546 157″L x 69″W x 51″H 1500 GA $2,668 SPECS DWG
1500 Gallon Norwesco Septic Tank – Single Compartment – 2MH 41758 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $2,755 SPECS DWG
1500 Gallon Norwesco Bruiser Septic Tank – Double Compartment – 2MH 41772 135″L x 55″W x 70″H 1500 UT, GA, MN, NY, OH, OK, WA $3,349 SPECS DWG

Concrete Septic Tanks Are Probably The Best Option — Build With a Bang

Concrete Septic Tank with a Capacity of 1000 Gallon When it comes to septic systems, whether you’re in the market for a new system or just need a replacement tank, you’ve arrived to the perfect location. As part of our recent investigation into different types of septic systems that are available for your house, we decided that it would be a good idea to also investigate the many types of septic tanks now available on the market. The following are the three most common types of septic tanks that are easily accessible for installation: When constructed properly and maintained on a regular basis, the majority of concrete septic tanks may endure for up to 40 years.

  1. Waste flow, home size, square footage, number of bedrooms, number of bathrooms, and a few other factors are taken into consideration in septic tank size recommendations and charts.
  2. Septic tanks are available in a variety of sizes, and you can even obtain tanks that are smaller than 1000 gallons; however, we recommend that you go with a tank that is at least 1000 square feet in size.
  3. Consult with a licensed expert before purchasing or installing any equipment if you’re going to install a new septic tank or septic system for the first time.
  4. ” A few of states are now requiring 1000 gallon tanks as the minimum size requirement.
  5. The popularity of the concrete septic tank can be attributed to its strength, weight, and longevity.

Check out these 6 septic systems available for your home.

Nowadays, most concrete septic tanks are sold with a two compartment design, as opposed to the earlier style one compartment tank that was more common previously. Two compartment tanks tend to perform a better job of filtering and separating waste than one compartment tanks, which is why septic experts advocate them over a single compartment tank. All compartments are constructed with access for cleaning and pumping, regardless of the number of compartments in the system. Because it can readily handle most 0-3 bedroom dwellings, a 1000 gallon septic tank is the standard size for domestic applications.

Heavy Duty Options

Many tanks are also available in “high duty” configurations, which generally have a reinforced top and bottom.

Purchasing the heavy-duty version may be a wise decision in the case that a vehicle, agricultural equipment, or other large piece of heavy machinery passes over the tank area.

Installation Requirements

Because of the size and weight of concrete septic tanks, they must be installed by a qualified specialist. These tanks are constructed of the hardest materials available, and while they are extremely durable, their installation necessitates the use of enormous, heavy machinery. If the intended or present site of your concrete septic tank does not allow for heavy machinery access, you may want to investigate a fiberglass or plastic (polyethylene) tank. Due to the fact that the majority of concrete tanks are precast, their sizes, weights, and dimensions are all different.

Lifespan and Durability

The method by which the concrete septic tank was constructed will have an impact on its long-term function. High-quality concrete, adequate water sealing, and the use of structural steel goods such as mesh and rebar will provide additional support, strength, and structural integrity to the structure. Keep in mind that concrete septic tanks are more prone to cracking and leaking than their plastic and fiberglass equivalents when exposed to exceptionally cold temperatures and pressures. Most concrete septic tanks have a lifespan of up to 40 years if they are constructed properly and serviced on a regular basis.

1000 Gallon Concrete Septic Tank

Septic tanks of 1000 gallon capacity or larger are the most typical size for household usage, as they can readily fit most 0-3 bedroom dwellings. Size Weight: The weight of each concrete tank is different. Some of the most common 1000 gallon concrete precast tanks are around 5′ 1″ X 8′ 2″ X 5′ 8″ in size and weigh almost 9,000 lbs. Others are approximately 5′ 1″ X 8′ 2″ X 5′ 8″ in size and weigh almost 9,000 lbs. Here are some examples of Jensen Precast projects completed in various cities around the United States.

1250 Gallon Concrete Septic Tank

Generally speaking, a 1250 gallon tank is a good choice for mid-size homes with 3-4 bedrooms. Size and weight: The sizes and weights of all concrete tanks are different. 1250 gallon concrete precast tanks are typically 5′ 9″ x 8′ 6″ x 5’8″ in size, with some of the more common models being 5′ 9″ x 8′ 6″ and others measuring 5′ 8″. The typical weight of a 1250 gallon concrete tank is 11,000 lbs, however this might vary depending on the distributor. Approximately 11 1/2 feet in depth, however this varies according on the distributor, state, and local statutes.

1500 Gallon Concrete Septic Tank

Generally speaking, a 1500-gallon tank is the most popular size for large homes with five or more bedrooms. Size and weight: The sizes and weights of all concrete tanks are different. The dimensions of some of the most common 1500 gallon concrete precast tanks are around 6′ x 10′ 9″ x 5′ 5″ in length and width. The typical weight of a 1500 gallon concrete tank is 12,000 lbs, which is rather heavy.

Approximately 12 feet in depth, however this varies according on the distributor, state, and local statutes. Baffles at the input and output of the system aid in the separation of solid waste items, oils, and scum from the effluent.

Inlet Baffles

When installing a septic tank, an inlet baffle should be put on the inlet part closest to the point at which the sewer tank joins from the house structure to the tank. Due to the fact that it prevents scum and oils from blocking the entrance pipe, the inlet baffle is critical to the overall health and effectiveness of the septic system. The intake baffle is a bottle neck that is especially designed to do the following:

  • In order to prevent the breakdown process from being disrupted, it is necessary to slow the effluent entering the septic tank. A fast rate of inflow of effluent might cause problems by mistakenly combining the settled solid waste with oils, scum, and effluent. Make sure no sewage gases are allowed to enter the sewer line. These gases have the potential to infiltrate back into a home or structure, generating a foul odor.

Outlet Baffles

Every septic tank should be equipped with an exit baffle that is connected to the discharge line. The outlet baffle functions as a bottle neck in the same way as the inlet baffle, but in the opposite direction. It is meant to:

  • Preserving the septic tank by keeping scum, oils, and solid waste contained inside
  • It is necessary to prevent the discharge of waste items other than wastewater into the output pipe, drain field, and leach field.

All effluent from the septic tank must be clear of solid waste before it may be discharged. Other than that, the solids and oils will pollute the drain field/leach field and result in backups and pollutants entering the surrounding environment. Ensure that your baffles are correctly built and that they are not in need of repair by consulting with a licensed septic technician before doing anything else. Septic tanks made of fiberglass or polyethylene (polyethelyene) are also a suitable option, especially if your location has specialized environmental requirements.

Mobility

In contrast to concrete septic tanks, which normally need a vehicle equipped with a crane and boom, fiberglass and polyethylene septic tanks are quite simple to transport. Therefore, fiberglass and plastic tanks are frequently employed in places where concrete septic tank delivery vehicles are unable to reach the tanks. The majority of fiberglass and plastic septic tanks weigh roughly 300 pounds or more, however concrete septic tanks can weigh up to 20-30 times as much.

Cost Effectiveness

If you’re seeking for a less expensive alternative to concrete, fiberglass and polyethylene (polyethylene) are excellent choices. The majority of fiberglass and plastic septic tanks are thousands of dollars less expensive than concrete septic systems.

Durability

When compared to a concrete septic tank, both plastic and fiberglass septic tanks have a lower likelihood of breaking. Furthermore, because fiberglass and plastic are nonporous materials, there is typically no problem with tree or bush roots growing into the tank and generating leaks as a result of root damage. Having said that, due to the tank’s smaller profile and lighter material composition, caution must be used during installation because heavy gear might easily harm it. Tanks made of fiberglass or plastic can be destroyed in the same way as concrete tanks can if too much weight is placed on the surface above them.

Despite the fact that plastic and fiberglass tanks are quite resilient, they can nonetheless leak under specific circumstances.

As a result, it’s important to contact with a septic installation specialist before making a final decision on a certain material. The size of the lot, the position of the tank, the amount of ground water, and the weather can all influence the selection.

Float

Plastic and fiberglass have a number of advantages, but they can also be troublesome. Yes, the lightweight character of these materials makes them perfect for installation, but same lightweight nature also results in a high level of buoyancy in the final product. It is possible that during a storm, a plastic or fiberglass tank can get dislodged from its couplings, causing considerable damage to the septic system and the homeowner’s property, with repair costs in the hundreds of dollars. A simple solution is to place a concrete slab on top of the tank to help weigh it down.

If you reside in an area with a high groundwater table, consult with a specialist to ensure that the higher water table will not cause harm to your fiberglass or plastic tank.

Leave a Comment