How To Keep Septic Tank Aerator Motor From Flooding? (Solved)

  • Use a chlorine solution of a half cup of chlorine bleach to each gallon of water to disinfect the area thoroughly. Pump the septic system as soon as possible after the flood. Be sure to pump both the tank and lift station.

How do I stop my septic tank from flooding?

As a preventive management step, you should keep stormwater runoff away from your system as much as possible. Water from roofs and driveways should be diverted away from the septic tank and drainfield area. Make sure your downspouts aren’t pointed directly at your drainfield.

Should septic aerator run all the time?

The aerator should run 24/7. It should continuously provide much-needed oxygen inside the septic tank of an aerobic system. The aerobic bacteria need air to survive.

How long should septic aeration pump run?

The aerator should run 24/7 nonstop and should not cost more than 10 dollars a month to run. If you electric bill is high something else is causing it or the system is not correctly hooked up.

Why does my septic tank overflow when it rains?

As rainwater floods over your drain field, the effluent from the septic tank will have no place to drain because the ground under the drain field is already saturated with water. As a consequence, the wastewater will back up in the tank and overflow in the leachfield.

Why is my septic tank flooding?

Flooding in a drain field means that the ground has been completely saturated with water. In such cases, there is a high probability that water will be able to flow back into the septic tank through compromised underground access ports. To conserve water, wash dishes in a small tub and dump the water outside your home.

How do I know if my septic aerator is working?

The surest sign your aerator has failed is an overwhelming unpleasant odor coming from where your system discharges, whether into a secondary treatment system or directly into the environment.

How often should an aerobic septic system Spray?

How often do I need to have septic system maintenance, or septic tank pumping? It is recommended that you have your septic system maintenance and pumped at least every two to three years or as needed according to usage and number of individuals dependent on the system.

Why does my septic pump keep running?

The most common cause of a sump pump system running continuously is when the sump pump float switch is stuck on the “on” position in your sump pit. This will cause it to run even when all water has been removed, which will burn out the pump prematurely.

How long does it take a septic aerator to work?

Most systems respond rather quickly, say within 4 weeks. The system will be fully functional during this period.

Why is my aerator alarm going off?

The cause of an alarm on aerobic systems is either the failure of the aeration device or high water level inside the tank. If you have an in tank aerator, take off the lid of the aeration chamber and see if the aerator is running. If the aerator is not operating or not putting out air, this is the cause of your alarm.

Can you put Ridex in an aerobic system?

Rid-X is full of helpful bacteria and enzymes that work to break down things like toilet paper and grease. These enzymes will not hurt your aerobic septic system. These enzymes will not hurt your aerobic septic system.

Is Ridex necessary?

According to the EPA and the Ohio Department of Health, not only are additives like Rid -X not recommended, but they actually have a detrimental and potentially hazardous effect on your septic system’s waste treatment process.

Where do you put chlorine in an aerobic septic system?

Chlorine tablets are added via an access port on the top of your aerobic septic system tanks. Usually there are two access ports, one for the chlorine, and one for accessing the aereation chamber. Depending on the system manufacturer’s model, the ports will either be secured by screw-on caps or latched caps.

Ultra-Air Model 735 RED Flood Resistant Septic Aerator

  • Alternative to Jet Aerators
  • WHITE SPLASH Flood Resistant Motor – Prevents System Backups
  • Brackets with a diameter of 12″ will fit a 10″ opening. 1/4 horsepower Baldor electric motor – manufactured in the United States
  • The motor runs at 1725 RPM and draws 4.6 FLA and 3.5 A of operating current. The aspirator tip is aerodynamic, and the shaft is balanced. The coupling is brass with set screws, and the suds restrictor is large plastic. The brackets are powder coated steel, and the feet are rubber.
  • This product operates on a 4 to 7 Amp circuit and is compatible with Jet OEM Control Panels. It is designed for continuous operation and comes with a 3 foot power cord with a standard plug. The National Sanitation Foundation has not tested or approved this product. Made entirely in the United States of America
  • It is possible to obtain replacement parts
  • It is also possible to obtain replacement alarms and control panels
  • Installing this product is a breeze! You just drop the motor into the tank via its handle and plug it in. Water and tank detritus are protected from the engine by using a motor shield. Condition: BRAND NEW THREE-YEAR LIMITED WARRANTY ON THE WHALE OF A DEAL

The Ultra Air was not tested on an NSF Certified Aerobic system, which is necessary in some jurisdictions for certain products. It is solely the purchaser’s obligation to verify with their local regulatory authorities to ensure that the purchase is in conformity.

THE WHITE SPLASH FLOOD RESISTANT MOTOR

The Ultra-Air Flood Resistant White Splash Motor is the only Flood Resistant Aftermarket Shafted Aerator on the market today. It is designed to withstand flooding. It is intended to serve as an alternative replacement for and comparable to units manufactured by other manufacturers. The Flood Resistant Ultra-AirTM was not intended to be used as a submersible aerator due to its flood resistance. A submersible aerator is designed to work continuously under water for the duration of its useful life.

  1. It will be able to withstand occasional high water levels and continue to operate.
  2. The utilization of your system will be impossible under these high water circumstances since there is nowhere for the water from your home to go, and this might result in a backup into your home.
  3. Septic Solutions is constantly striving to supply our clients with the most up-to-date and creative goods available on the septic market at any given time.
  4. The only Aftermarket Flood Resistant Shafted Aerator available anywhere is now available to those who are concerned about their Aerator flooding.
  5. Septic Solutions is pleased to introduce our newest innovative product, the Ultra-AirTM Flood Resistant White Splash, to the market.
  6. It is now up to you to make your decision.

WHO NEEDS THE FLOOD RESISTANT ULTRA-AIR®?

The vast majority of property owners who already have a septic tank shaft aerator do not require a Flood Resistant Ultra-AirTM. However, there are some situations in which a Flood Resistant Ultra-AirTM may be advantageous. EXAMPLE 1: Your system may have been operating normally for several years then all of a sudden you are slammed by a 6 inch downpour in a matter of hours. This is an uncommon occurrence, but it does occur. Your system drains into a field absorption system, and the terrain in your yard is quite level.

If the water level rises to the point where it enters your motor, and your motor is not Flood Resistant, your motor will most likely break down.

EXAMPLE 2: Your system is comprised of a lift station and an effluent pump that transports wastewater to a field absorption system, spray irrigation system, drip irrigation system, mound system, or another location.

When the lift pump fails and the water level in the lift station rises due to any reason (e.g., the alarm has been turned off, the alarm wire has been damaged, the alarm has been damaged, etc.), and you continue to use water in your home and send it out to the septic system where the water is not being pumped away, the water level in the lift station will rise and begin backing up into the aerobic system.

  • After only a short amount of time, the water level might rapidly grow to the point where it enters your aerator motor and causes it to malfunction.
  • FOR EXAMPLE 3: Your system is equipped with a filter that has the potential to become clogged over time.
  • The Ultra-AirTM White Splash was created specifically to manage circumstances like these without causing damage to the engine.
  • For some reason, the 4 inch pipe that exits your aerobic system becomes blocked or even collapses for no apparent reason.
  • The Ultra-AirTM White Splash was created specifically to manage circumstances like these without causing damage to the engine.
  • It is expected that alarms will sound in most tanks when excessive water levels are detected within them.
  • The Flood Resistant Ultra-AirTM will offer those of you who are concerned about the possibility of flooding within your tank with the peace of mind that this motor will not be harmed if this does occur.

The Ultra-AirTM Flood Resistant White Splash is the only Aftermarket Flood Resistant Shafted Aerator on the market today that is also flood resistant.

MADE 100% IN THE USA!

The Ultra-Air Model 735 aerator is designed and manufactured entirely in the United States! Baldor Electric Motor Company in Fort Smith, Arkansas, manufactures the electric motors used by Septic Solutions exclusively for this purpose. Septic Solutions, Inc. owns the molds used in the production of the plastic pieces, which are manufactured in Indiana. The brackets are stamped, bent, and powder-coated in our hometown of Dieterich, Illinois, where they are also manufactured. The shaft and brass couplings are also manufactured here here in Dieterich, Illinois, where we were born and raised.

  • With the Ultra-Air Model 735, you are purchasing a high-quality product that has been totally produced and constructed in the United States, from start to finish.
  • that has been registered.
  • Septic Solutions, Inc.
  • Septic Solutions, Inc.
  • These pumps and parts are comparable to your existing Jet aerator, Norweco aerator, or other Septic Tank aerator.
  • It is solely the purchaser’s obligation to verify with their local regulatory authorities to ensure that the purchase is in conformity.

ULTRA-AIR® MODEL 735 RED ADVANTAGES

The Ultra-Air Model 735 aerator is designed and manufactured entirely in the United States! Baldor Electric Motor Company in Fort Smith, Arkansas, manufactures the electric motors used by Septic Solutions exclusively for this purpose. Septic Solutions, Inc. owns the molds used in the production of the plastic pieces, which are manufactured in Indiana. The brackets are stamped, bent, and powder-coated in our hometown of Dieterich, Illinois, where they are also manufactured. The shaft and brass couplings are also manufactured here here in Dieterich, Illinois, where we were born and raised.

With the Ultra-Air Model 735, you are purchasing a high-quality product that has been totally produced and constructed in the United States, from start to finish.

FLOOD RESISTANT MODELS AVAILABLE!

It is the only aftermarket product available that has a Flood Resistant motor, and it is the Ultra-Air® Model 735. It is the same Baldor 1/4 HP electric motor as is used in the White Splash Flood Resistant device, but this motor has been specifically sealed and is capable of withstanding being immersed for short periods of time.

If you are experiencing system backups as a result of an outlet being clogged or a failing submersible pump, theFlood Resistantunit might be a good choice.

WELD-FREE BRACKET SYSTEM

The Ultra-Air® Model 735 is comprised of an eight-piece bracket system (4 top, 4 bottom) that does not require any welding. The bottom and top supports of some of the units available on the market are joined together by a four-piece bracket system that contains spot welds to hold them together. When subjected to the high moisture tank environment and the continual vibration of the motor, these spot welds create a weak point in the bracket system, which can eventually cause the brackets to fail.

No welds and no weak areas are included in our bracket system, which means it will not fail over time.

MOTOR SHIELD/HANDLE WITH FRESH AIR HOSE BARB

The Ultra-Air® Model 735 is equipped with a motor shield that features a handle and a fresh air hose barb for easy operation. Installation and maintenance of your aerator are made easier with the handle on the unit. To constantly verify that the engine is bringing in new oxygen into your system, you may link a hose from the top of the motor to the vented lid of your tank, using the air hose barb. It will be much easier to insert your motor in and out of the tank with the handle that has been particularly built to prevent damage and probable bending of the shaft, which would greatly limit the life of your motor.

This is a very significant characteristic that many of the competitor companies do not offer.

LARGE 5′ SUDS RESTRICTOR

The Ultra-Air® Model 735 is equipped with a big 5″ suds restrictor for maximum performance. The suds restrictor is meant to be installed above the level of the water in the tank in order to prevent foam and suds from entering the electric motor during operation. Other versions available on the market include suds restrictors that are just 2″ to 3″ in diameter, which are insufficient to protect the engine from foam and suds. The suds restrictor can also serve as an alert in the event of excessive water.

This will sound an alarm and alert you to the fact that there is a problem.

See also:  How To Have Septic Tank Test? (Best solution)

AERODYNAMIC ASPIRATOR THAT IS TRUE TO THE OEM DESIGN

The Ultra-Air® Model 735 is equipped with a huge 5″ suds restrictor for maximum performance and efficiency. Designed to be installed above the water level in the tank, the suds restrictor prevents foam and suds from entering the electric motor and causing it to malfunction. Suds restrictors that are found on other models available on the market are insufficient for protecting the engine from foam and suds, and they should be replaced with larger ones. This device can also function as an alert in the event of excessive water levels in the reservoir.

It will cause the motor to draw excessive current and will cause the reset button on your control panel to be triggered if the water level rises above the suds restrictor. You’ll receive an alert and be made aware that there is a problem by doing this.

Ultra-Air Model 735 Septic Aerator

The Ultra-Air® Model 735 is equipped with a huge 5″ suds restrictor as standard equipment. The suds restrictor is meant to be installed above the level of the water in the tank in order to prevent foam and suds from entering the electric motor. Suds restrictors that are found on other models available on the market are insufficient for protecting the engine from foam and suds. The suds restrictor can also be used as an alert in the event of a flood. If the water level rises above the suds restrictor, the motor will draw excessive current and hit the reset button on your control panel.

  • Drinking well water should be avoided until the water has been analyzed. Contact your local health department for further information. Do not use the sewage system until the water level in the soil absorption field is lower than the water level in the surrounding area of the home. If you feel that your septic tank has been damaged, you should get it professionally inspected and maintained. The presence of settling or an inability to take water are both signs of deterioration. Because most septic tanks are below ground and entirely covered, flooding does not usually do any harm to them. Septic tanks and pump chambers, on the other hand, can get clogged with silt and debris and must be properly cleaned. If the soil absorption field becomes blocked with silt, it may be necessary to build a completely new system. Septic tanks should only be cleaned or repaired by skilled professionals since they may contain potentially hazardous gases. Inquire with your local health agency for a list of septic system contractors who operate in your neighborhood. Cleaning and disinfecting the basement floor is necessary if sewage has backed up into the basement. To disinfect the area thoroughly, make a chlorine solution by mixing half a cup of chlorine bleach with each gallon of water. After a flood, pump out the septic system as quickly as possible to avoid contamination. Make careful you pump the tank as well as the lift station. This will clear any silt or debris that may have been washed into the system during the rainy season. It is not recommended to pump the tank while the drainfield is flooded or saturated. Pumping the tank is simply a short-term remedy at the best of times. Pumping it out might cause the tank to attempt to float out of the ground, resulting in damage to the inlet and outlet pipes. Do not compress the soil over the soil absorption field by driving or operating machinery in the vicinity of the soil absorption field. Soil that has been saturated is particularly prone to compaction, which can impair the ability of the soil absorption field to treat wastewater and ultimately result in system failure. Before reconnecting the electricity, check for any damage to all of the electrical connections. Examine to see that the manhole cover on the septic tank is securely fastened and that no inspection ports have been obstructed or damaged. Examine the plants surrounding your septic tank and soil absorption field for signs of disease. Damage caused by erosion should be repaired, and portions should be sodded or reseeded as needed to ensure turf grass cover.

Keep in mind that if the water table is high or your sewage system is threatened by floods, there is a possibility that sewage will back up into your residence. The only way to avoid this backup is to reduce the amount of strain placed on the system by utilizing it less frequently.

  1. What are some of the recommendations made by professionals for homes who have flooded septic systems
  2. And Make use of your common sense. If at all possible, avoid using the system if the earth has become saturated and inundated with water. It is unlikely that the wastewater will be cleansed, and it will instead become a source of pollution. Conserve as much water as possible when the system is re-establishing itself and the water table is depleted. Prevent silt from entering septic systems with pump chambers by installing a filter. The pump chambers have a propensity to fill with silt when they are inundated, and if the silt is not cleared, the chambers will clog and obstruct the drainfield. While the earth is still damp, it is not recommended to open the septic tank for pumping. Mud and silt may find their way into the tank and end up in the drain field. It’s also possible that emptying out a tank that’s been sitting in soggy soil can cause it to “pop out” of the earth. (Similarly, systems that have been recently installed may “pop out” of the ground more quickly than systems that have been in place for a longer period of time since the soil has not had enough time to settle and compress.)
  3. While the soil is still wet or flooded, it is not recommended to dig into the tank or drainfield area. While the soil is still wet, it is best not to perform any heavy mechanical operations on or around the disposal area. These operations will have a negative impact on the soil conductivity. It is likely that flooding of the septic tank caused the floating crust of fats and grease in the tank to rise to the surface. Some of this scum may have floated to the surface and/or partially filled the outlet tee, but this is unlikely. If the septic system backs up into the home, first examine the tank for an obstruction in the outflow. Floodwaters from the home that are passed through or pumped through the septic tank will produce greater flows through the system. Clean up any floodwater in the house without dumping it into the sink or toilet, and give enough time for the water to recede. This may result in sediments being transferred from the septic tank to the drainfield, which will block the drainfield. Discover the location of any electrical or mechanical equipment in the system that may have been flooded and avoid coming into touch with them until they are dry and clean
  4. The presence of mud and silt has a propensity to block aerobic plants, upflow filters, trickling filters, and other media filters, among other things. Cleansing and raking of these systems will be required.

Protecting Your Septic System From Flooding

Septic waste can back up into your home during floods, and there are precautions you can do to minimize the risk of this happening. Photograph courtesy of George Hurd of Penn State Extension A buildup of water in your septic system’s drainfield might lead it to overload, which can cause the treatment of your wastewater to slow down or stop completely. If this occurs, you face the risk of septic waste backing up into your home, which is particularly dangerous if your drainfield becomes plugged.

  1. There are measures that you may take now to assist secure your system before this occurs, if you choose.
  2. Rainwater collected on rooftops and driveways should be channeled away from the septic tank and drainfield for disposal.
  3. To encourage rainwater to flow off of your system rather than onto it, the soil above your system should be somewhat mounding up.
  4. Have your septic system examined at least once a year.
  5. The sludge and scum levels in the tank should be examined on a regular basis, and the drainfield should be monitored for smells, damp areas, and surface sewage on a regular basis.
  6. This is an extremely crucial stage in the ongoing maintenance process.

It is recommended that you have a licensed plumber install a backflow preventer on the building sewer if you live in an area that is susceptible to flooding, according to the Minnesota Pollution Control Agency factsheet, “What To Do With Your Septic System During A Flood.” If you live in a flood-prone area, you should have a backflow preventer installed on the building sewer so that sewage does not backup into your home during a flood.

Because there is some worry that a basic check valve may fail to close correctly, sewage may back up into the residence, it is advised that a backflow preventer be installed.

Additional information on managing your septic system during a flood can be found in the U.S.

More Information

  • The National Environmental Services Center may be reached at 800-624-8301, and the Pennsylvania Department of Environmental Protection can be found by searching for “Onlot Disposal System.”

Septic Systems – What to do after Severe Weather – Oklahoma State University

PSS-2920 was published in April of this year. Submitted by Sergio M. Abit Jr. and Danielle Walker Septic systems were installed in more than half of the new homes developed in Oklahoma between 2002 and 2017. (Abit, 2019). At the moment, septic systems are installed in at least 30% of all homes in the state (SORA, 2015). As predicted, a large proportion of the population lives in small towns or rural regions that are outside the service area of centralized wastewater treatment plants. Oklahoma is well-known for having extreme weather occurrences occur in it.

  1. It is possible for counties in the state’s northeastern part to have up to 28 severe weather occurrences each year in some areas (NOAA, 2013).
  2. Flooding has been reported in every county in the state, with the majority of the flooding happening in the northeastern and southern portions of the state (FEMA, 2014).
  3. It is the purpose of this information sheet to discuss the impact of floods and power outages on the two most frequent types of septic systems in Oklahoma: 1) traditional or gravity-driven systems, and 2) aerobic treatment systems or units (ATU).
  4. It also includes information on what homes with septic systems should do in the event of a flood or a power outage.

Conventional Septic Systems and Severe Weather Hazards

In a conventional system, the wastewater is treated partially in the septic tank and then transported to the soil treatment area (STA) for complete treatment (Figure 1). It is not impacted by power outages since gravity moves the water through this system, which means it does not require energy to operate. In contrast, flooding of the area above the septic tank and/or STA might result in major difficulties if left unattended. If the septic tank lids are not waterproof, water might seep into the tank and cause damage.

Regardless of whatever scenario occurs, the septic tank may get overfilled, resulting in one of two probable outcomes: 1) sinks and toilets may no longer drain, and/or 2) untreated water from the tank will back-flow into the house.

ATUs and Severe Weather Hazards

The ATU treatment train is made up of three components: a septic tank (also known as a garbage tank), an aeration tank, and a clarifier (Figure 2). This system requires power to run the aerator, which feeds air to the aeration chamber, as well as the pump, which disposes of the treated effluent to the dispersion area, among other components. Without power, residential wastewater will not be processed, and the ongoing use of water will result in the tanks continuing to fill. A prolonged power outage (i.e., three or more days) may result in a strong, unpleasant stench emanating from the tanks, as well as sinks and toilets that are unable to drain properly.

On the ground surface, generally immediately above the aeration tank, is a control box that houses the aerator (or air pump) and an electronic panel/timer that controls the aeration.

Furthermore, if the tank’s lids are not waterproof, floodwater may enter the container.

A schematic representation of an aerobic treatment system is shown in Figure 2.

What to do when any septic system is flooded

  1. Drains in the basement should be plugged or sealed. In this way, sewage from the septic tank will not back up into the home. Remove the ATU if there is a strong probability that the control box will be inundated during a flood event. Keep in mind that the aerator and the electrical panel in the control box are both powered by electricity, and both might short circuit if they are both turned on at the same time while they are flooded. Reduce the amount of water you use as much as feasible. You have no way of knowing how long the floods will continue. The possibility of sewage backing up into the house exists when it floods. The most straightforward method of lowering this danger is to lessen pressure on the system by using less water. If your sinks are draining more slowly than usual, immediately turn off the water supply since this might indicate that water is backing up from the tank into the home.
See also:  What Happens If A Septic Tank Is Not Holding Water? (Solution found)

What to do when the floodwaters recede

  1. Continue to reduce your water use (assuming there is no backflow). Surface flooding is no longer permitted, however water may still be pumped into the septic tank and into the trenches of traditional wastewater treatment systems in some cases. In the meanwhile, it is advisable to continue to reduce water use until the system has been inspected and/or fixed by a professional. Backflow-affected locations in the house should be cleaned and disinfected. This must be done with caution since septic tank wastewater includes hazardous germs and dissolved compounds that must be removed. Make use of the services of experienced cleaners to ensure your safety. Examine the many components of the system with your own eyes. Watch for indicators of water leaking into the tanks, eroded regions, accumulation of sediments in the control box, a bad odor, and corroded electrical components, among other things. When it comes time to engage a professional service provider, the results of a visual examination will be beneficial. They will almost always ask for information that will assist them in understanding the scope of the problem
  2. For example, It is recommended that you have a competent service provider examine the ATU before turning it on. It is quite likely that electrical components may require repair or replacement. Due to the presence of toxic compounds and potentially deadly gases in septic tanks, only qualified professionals should clean or repair them. For a list of septic system service companies in your region, contact your local Department of Environmental Quality (DEQ) office (). Do not consume well water until the results of the tests show that it is safe. You may find a list of certified laboratories in your region by visiting the DEQ Laboratory Facility Search website ().

What to do in a power outage

  1. Reduce the amount of water you use as much as feasible. You’ll never know how long the power outage will persist because it’s unpredictable. If there is no electricity, wastewater will remain in the ATU tank, and continuing use will result in untreated water backing up into the home. If the electricity is down for more than three days, it is no longer acceptable to flush water down the toilet. If a backup electrical generator is available, use it to power the system
  2. If the power is restored after a few hours, check to see if the system is still operational. This may be accomplished by just listening to see if the aerator is producing a buzzing sound. Make any necessary adjustments to adapt the dispersion timer to the correct schedule
  3. After a prolonged power outage (i.e., one that lasts more than three days), continue to reduce water consumption for the next three days. The aerobic bacterial population in the aeration chamber is used to treat the water in the ATU system. When exposed to anaerobic circumstances, such as those caused by a protracted power outage, their numbers plummet dramatically. Several days will be required for the bacterial population to reestablish itself at a level that will allow it to efficiently treat wastewater.

References

Sergio M. Abit Jr., Ph.D., is a specialist in on-site wastewater treatment systems. Danielle Walker is a student studying soil science.

Was this information helpful?

Do you require assistance? For Professional Assistance, please contact us at 1-877-925-5132 toll free.

ULTRA-AIR™ MODEL 735 REDPRODUCT DIMENSIONS ULTRA-AIR™ MODEL 735 BLUEPRODUCT DIMENSIONS

Put Your Trust in the Professionals With Over 20 Years of Wastewater Industry Experience. Septic Solutions® is pleased to introduce the Ultra-AirTM Model735 to you! The most technologically superior alternative replacement shaft aerator currently available on the market! Compared to our previous model as well as other versions now available on the market, this new device has many more enhanced design characteristics. All of the components that make up this product are made right here in the United States of America!

  1. Our long-lasting 1/4 HP hollow shafted motor with 1725 RPM will operate smoothly and create roughly 2.0 cfm of airflow to ensure that your aerobic system is functioning properly.
  2. Because the motor will only be operating at around 75% of its maximum capacity, it will have a lengthy service life.
  3. The item is simple to install and remove from the tank thanks to the included handle.
  4. As a result of this air intake, the engine is able to suck in clean air from outside the tank, which is drawn down via the handle and into the tank through the aspirator tip located at the bottom of theshaft.
  5. Using our newly designed brackets, you will have a sturdy base, as well as a tight fit inside the riser, which will prevent the motor from being able to travel back and forth between positions.
  6. As an added precaution against vibration noise, rubber feet are included with each bracket.
  7. Suitable for use with Jet Aeration systems, these brackets are available.

These brackets are designed to work with the NorwecoSingulair air conditioning systems.

The end of the shaft, where the aspirator will simply screw into it, is also threaded in the opposite direction as the rest of the shaft.

As a result, the size of the suds restrictor on the shaft has been increased to better protect it from the severe environment within the tank.

Our newly designedAerodynamicAspirator is something we are really enthusiastic about.

According to our tests, the aerodynamic advantage includes a reduction in the amperage demand of the motor by up to.75 of an amp, from 4.25 amps to 3.5 amps, as a result of the reduced drag.

Recommendations from the manufacturer, as well as important information:It is highly recommended that the ULTRA-AIRTM MODEL 735 septic aerator be allowed to operate continuously in order to provide optimal performance and to ensure that an adequate oxygen supply is readily available inside the septic tank to promote the growth of aerobic bacteria.

  • In addition to the pre-wired 115-voltplug, the ULTRA-AIRTMMODEL735 aerator comes with an extension cable that may be used to plug into a standard electrical socket or an extension cord for reference.
  • When the motor and the suds restrictor are installed in a tank, they must remain above the greatest liquid levels in the tank at all times.
  • In addition to being hollow, the stainlesssteelshaft is attached to another hollow shaft that continues into the middle of the motor.
  • It is recommended that the interior of these shafts be examined at least once a year to verify that there are no constraints.
  • Despite the fact that the ULTRA-AIRTMMODEL 535 aerator is made with permanently lubricated bearings in a fully enclosed housing, it was not intended to be installed in a flood-prone environment.
  • A flooded motor will not be covered by the manufacturer’s warranty.

It is possible to aerate a pre-existing septic tank without having to worry about flooding. This is because the air pump is housed outside the tank and diffuses air into the tank using our patent-pending weighted diffuser assembly.

Aeration Septic – Fresh Lemon Blue – Septic Tank Treatment

It is possible that if you do not maintain and clean your septic tank system on a regular basis, you will significantly increase your chances of something going wrong, which might result in you losing thousands of dollars. Backups and overflows of your septic tank into your home through sinks and toilets are just a few examples of these problems. It might also cause sewage sludge to overflow into your yard, which could be dangerous.

Why Fresh Lemon Blue?

  • To avoid waste accumulation in septic tanks, this septic treatment employs a combination of friendly bacteria and strong, hardworking enzymes to break down and digest the organic elements that block pipes, tanks, and drains. There are several enzymes that are extremely hard workers: Contains a combination of tough enzymes that prevent sludge from building up in your system, including Lipase, which liquefies grease, Cellulase, which breaks down paper and fibers, Amylase, which breaks down starch, Pectinase, which liquefies pectin and gums, and Protease, which blasts away proteins
  • Beneficial bacteria strains that are highly specialized: It also contains types of beneficial bacteria, whose population doubles every 20 minutes, allowing them to be more effective. These beneficial microbes break down waste, allowing your system to function cleaner than ever before. Protects you from a wide range of plumbing problems: Slow drains, sludge building in your septic tank, drain flies, water backups, and blockages may all be avoided without causing damage to your pipes and fittings by using this product. All-natural ingredients that are safe for the environment: Because this septic tank cleaning does not include any harsh chemicals, you won’t have to worry about contaminating the environment while using it. Additionally, it has a lovely, fresh lemon aroma about it.

How does Fresh Lemon Blue work?

A uniquely formulated combination of natural enzymes and beneficial bacteria, Fresh Lemon Blue increases the sludge and solids digesting capacity of your septic system, allowing it to perform better. When a living thing produces a material that functions as a catalyst to bring about a certain biochemical reaction, such substance is referred to as an enzyme. Because each enzyme has a highly unique purpose and capacity, it is required to use a combination of enzymes in order to successfully treat waste in a septic system.

Because the bacterial colonies within a septic system are responsible for eating and digesting waste, bacteria are vitally crucial to a septic system’s overall performance.

Fresh Lemon Blue Benefits

  • Increasing the sludge and solids-eating capacity of your septic system is recommended. Save money by having your septic tank pumped less frequently. Getting rid of damp soil and surface puddles caused by obstruction of the drain field is essential. Fresh Lemon Scent can be used to mask scents that aren’t desirable. Maintain the health and seamless operation of your complete plumbing system. Treatment that is completely natural and won’t affect the environment

How does FLB compare to other septic tank maintenance products?

“Excellent stuff! This is something I use once a month to assist keep our drain pipes in good condition. It does not cause damage to your plumbing, as some products do. Eco-friendly. It is completely safe for your septic system! This product comes highly recommended by me.” — Barry R., Ph.D. 2/25/2015 “I am quite satisfied with your goods. This is the second time we have ordered, which speaks volumes about our happiness with the product. Your product does exactly what it says it will. Every instruction you give us is carried out to the letter.” – A.B.S.

  • “It really works!” — John O.
  • This has shown to be effective in keeping our vintage septic system (built in the 1960s) working smoothly.
  • 10/26/2016 “It’s simple to use.
  • 10/6/2017

Maintaining your septic system FAQ’s

1.) Water conservation is important. It is possible to increase the lifespan of your septic system by conserving water. Septic tank systems are put under a lot of stress, which may be eased by reducing the quantity of wastewater you generate. Not only will this increase the life of the system, but it will also reduce the likelihood of system failure. (2)Make certain that you are working with a qualified septic service business In the event that a problem arises with your septic system, you want to be able to contact a dependable and licensed septic provider that will be able to come to your home as quickly as possible to assist you.

If you consistently pump out your septic tank, you can be confident that you are lowering the likelihood of a problem happening.

FLB makes it easier for your septic system to break down waste and reduces the amount of accumulation in your septic system.

Septic inspections are necessary in order to detect any potential problems before they manifest themselves.

5.)Be aware of what you should and should not put into your septic systemIt is critical to understand what should and should not be placed into your septic system. The following is a list of items that should never be placed in your septic system.

  • Fats or grease
  • Motor oils or fuels
  • And other substances Diapers that are disposable
  • Coffee grounds, egg shells, and nut shells are examples of waste materials. Cigarettes with a filter tip
  • Napkins, tampons, or condoms for personal hygiene
  • A roll of paper towels or a rag
  • Paints or chemicals, for example.

However, while baking soda and vinegar may be used as a DIY septic tank treatment, we strongly urge that you choose a product that has been tested and confirmed to provide the best results in terms of keeping your septic system healthy and functioning correctly instead. Fresh Lemon Blue is a septic tank treatment that may be applied once a month in two simple steps: 1.) Remove the easy-open packet from the refrigerator. Pour the liquid down any drain or toilet in your house. 2.) In order to guarantee that Fresh Lemon Blue is beneficial to your whole plumbing system, we propose that you use a new drain once a month.

While you sleep, Fresh Lemon Blue will begin to work for you.

Some of these advantages are as follows:

  • In order to increase the sludge and solids-eating capacity of your septic system, Saving money by reducing the amount of septic tank pumping required
  • Getting rid of damp soil and surface puddles caused by obstruction of the drain field
  • Using a Fresh Lemon Scent to replace any unpleasant scents
  • Keeping your complete plumbing system in good working order and running freely
  • Using an all-natural procedure that will have no negative impact on the environment

The ability of your septic system to consume more sludge and solid waste. fewer septic tank pumping means less money saved. Removing squishy soil and surface puddles caused by obstruction of the drainage field; Using a Fresh Lemon Scent to replace any undesirable aromas. Maintaining the overall health and efficiency of your plumbing system; Using an all-natural treatment that will have no negative impact on the environment

See also:  What Is My Septic If It Has No Tank? (Solution)

Maintaining and Servicing Your Aerobic Treatment Unit

Maintenance and upkeep of aerobic treatment systems must be performed on a regular basis. Using air infiltration and natural bacteria, residential aerobic treatment systems may convert waste water from the home into groundwater that can be disposed of in the environment without the need for additional treatment. Homeowners should service their system twice a year on average, according to industry standards. Servicing the motor in your septic system is equally as critical as servicing your automobile’s engine or transmission.

Consider the following suggestions to ensure that your system is operating at peak efficiency:

  1. Keep Trees Away from Septic System: You may have a single magnificent tree near your septic system, but that tree has hundreds of root tentacles beneath the surface of the earth. A large amount of water is required by trees
  2. As a result, tree roots are frequently seen entangling themselves in concrete or plastic septic tanks, where there is an unending supply of water available. They have the potential to clog and ruin concrete tanks and motors if not limited or eliminated by a professional service provider
  3. Avoid Building Patios or Decks Over Your Septic System: Your septic system is often placed in the rear of your home, near areas that you may wish to finish as a deck or patio. Avoid building patios or decks over your system. It is critical to prevent any form of building in the vicinity of these systems. A deck over an aerobic treatment unit, for example, will make it practically hard for service providers and septic pumpers to maintain the system. Roof drains and surface water should be diverted away from your system: Your aerobic treatment unit is only capable of dealing with a set quantity of water and waste generated by your home at a given time. Overflows are possible if the system is placed near to an area with an excessive amount of surface or drainage water. It is possible that this additional water can flood the engine inside your system, resulting in costly repairs. Increase Water Efficiency in the Home: Avoid washing dishes, laundry, and taking a shower at the same time to save on water use. It is conceivable that your septic system will get overwhelmed if you attempt to complete various home duties at the same time, despite the fact that it may be more convenient to do them at once. It is possible that untreated water may seep into the environment since the septic system will not have enough time to fully treat all of the waste.

If you would like additional information on how to maintain and service your aerobic treatment unit, please contact Aeration Septic at (330)854-4405.

Jet Aerator – Jet 700 Septic Aerator – Jet 700 Septic Tank Aerator Motor – Official Jet Brand Septic Aerator

Designed to withstand flooding, the flood resistant Jet 700 Septic Aerator provides the oxygen and mixing necessary to enable Jet’s proprietary treatment process, which transforms wastewater into colorless, odorless liquid and gas. Fresh outside air is drawn into the tank treatment compartment by the aerator shaft, which rotates and blends it with the wastewater within. During the treatment process, air passes through the aerator and into the tank, supplying oxygen for the process. There is no other manufacturer that can compete with Jets in terms of quality, dependability, and dependable long-life.

With the Jet 700++ Aerator, you get a limited 30-month guarantee and repair service program that is unmatched in the market. Upon that, a LIFETIME Factory Exchange Program becomes effective immediately following the expiration of the limited warranty.

$ 999.955 is currently available in stock. 100 percent MONEY BACK GUARANTEE IN THE EVENT OF A FAILURE Designed to withstand flooding, the flood resistant Jet 700 Septic Aerator provides the oxygen and mixing necessary to enable Jet’s proprietary treatment process, which transforms wastewater into colorless, odorless liquid and gas. Fresh outside air is drawn into the tank treatment compartment by the aerator shaft, which rotates and blends it with the wastewater within. During the treatment process, air passes through the aerator and into the tank, supplying oxygen for the process.

With the Jet 700++ Aerator, you get a limited 30-month guarantee and repair service program that is unmatched in the market.

Why is My Septic Pump Tripping the Breaker? – 5 Reasons

Have you ever had a sewage pump trip a gfci breaker in your home or business? Is your first thought “why is my septic pump tripping the circuit breaker?” There are a variety of reasons why a sump and septic pump circuit breaker may be tripped. The majority of these issues are caused by a ground fault or an obstruction caused by debris. If you are experiencing any of these problems, it is recommended to consult with a specialist. This is due to the fact that an incorrect pump repair might result in more serious difficulties.

Why Septic or Sump Pump Trips GFCI Breakers

Pumps for sump and septic systems are two distinct types of pumps, yet their motors perform almost the same purpose in both cases. In the event of flooding, the sump pump removes extra water from basements; in contrast, the septic pump removes excess water and waste from septic tanks. When a septic aerator continues tripping the circuit breaker, you should contact a professional to get it looked at right away. This is due to the fact that when these pumps are not properly maintained, they can cause damage to your property and even personal injury.

1. Damaged Pump Motor

A faulty pump motor may be the most typical cause of your pump’s inability to perform properly, resulting in it tripping its circuit breaker. You may determine whether or not your pump motor is damaged by turning it on and listening for any buzzing sound that occurs. If there is no sound, contacting a professional is the most effective approach to resolve the situation.

2. Leakage

It is possible that your septic pump or sump pump breaker has tripped as a result of a water leak or dampness. GFCI breakers are designed to detect the presence of water or moisture in the pump’s wiring or inside the motor, and they will trip immediately if this is detected. It is also for this reason that it is recommended to connect your pump to a GFCI breaker. Besides that, water and moisture that enters the motor pump might cause harm to your machine by developing corrosion and preventing it from functioning properly.

3. Blockage

The other reason that the septic system and sump pump continuously tripping the breaker is because there is a buildup of dirt. It is possible that the impeller will have difficulties spinning if there is dirt within the pump; even worse, the impeller may become stuck due to the debris inside. Due to the increased current draw required by the pump in this situation, the breaker trips.

When the pump breaker trips after only a few minutes of operation, this is a symptom of a blockage. Furthermore, there are occasions in which your pump can trip immediately upon startup owing to a blocked pump impeller, which can be quite frustrating.

4. Damaged Electrical Wires

If your pump is more than a decade old, the electrical wiring may also become brittle over time. Animal bites can also be a contributing factor, particularly if the wire is not properly secured. There have also been occasions where wire has been broken during the installation or maintenance process.

5. Using a Low Rating Extension Cord

While using an extension cable for a septic pump is not ideal, it is sometimes necessary. Some extension cables, on the other hand, may be too light for them. Using an extension cable with a low rating may cause your pump fuse to blow or your circuit breaker to trip. If you see any of the indicators listed above, it is preferable to contact certified maintenance. For those who have already purchased a replacement sewage pump, this video from Wholesale Septic Supply will assist you in understanding how to wire it in properly.

Conclusion

If you see any of the indicators listed above, it will assist you in determining why your septic pump is tripping the breaker. Furthermore, if you find yourself in any of the conditions listed above, you should contact a specialist to examine your system. So, are you experiencing difficulties with your septic pump? Is the information provided above of assistance to you? Is there anything more you’d like to share that wasn’t covered here? Please share your thoughts in the comments section below so that we can figure out how to solve it!

Fact Sheet: Home Aeration Units – Cavitette

The location where you now reside in Hamilton County is not serviced by sewers. A home aeration device is used to handle the trash generated by your household. These units are available in a variety of forms and sizes. They are also referred to as “cavitettes” in some circles. Cavitette is the brand name of one of the aeration units that is now in use in our county. Coate Aer, Jet, Multi-Flo, Norweco, and Oldham are some of the other brands that have been utilized. Despite the fact that aeration units come in a variety of shapes and sizes, the essential concept of operation is the same: air pumped into sewage creates agitation and oxygen, which in turn helps bacteria to break down organic waste into carbon dioxide and water.

Treatment Process

Cavitette units are designed to create effluent that does not meet contemporary water quality requirements, hence they are not permitted to be used. A properly running unit, on the other hand, will discharge a clean effluent. The procedure that is followed is as follows.

  • In the treatment procedure, cavitette units do not provide for settling during the primary phase (pre-treatment/settlement). This chamber receives raw sewage from your residence first, before proceeding to the next chamber. (See1) Aerobic microorganisms that degrade organic materials in wastewater benefit from the agitation and oxygen provided by the injected air. Clarification — Because there is no agitation in the second chamber (2), suspended particles that have remained in the aerated sewage can settle. It is designed in such a way that sediments flow back into the aeration chamber for further treatment.

In the treatment procedure, cavitette units do not perform filtration or disinfection. Tertiary (Filtration/Disinfection): Some units may be equipped with a separate chlorinator for disinfection purposes.

Care of your Unit

Your Cavitette treatment plant may have a capacity of 750 or 1500 gallons per day. Please keep in mind that certain aeration devices are positioned extremely deeply below the surface of the soil. Maintenance on the units presents unique safety concerns and should be carried out by a qualified professional with extensive expertise. You should call a maintenance firm that is registered and bonded with the Health District if you fulfill the previous conditions or if you are uncomfortable with the following processes.

Cracks in the lid that allow surface water to enter the system or that hinder Health District employees from inspecting the system should be looked for.

Lids that cannot be moved without cracking or collapsing must be replaced immediately. Aeration Tank– Remove the cover from the aeration riser and look for the following issues:

  • If the electrical service wire is frayed or if there is a black residue on the wire, it should be replaced. A secure connection between the motor/blower and the diffuser bar should be made using the air supply line. No cracks or breaks should be present in the belt/coupler-belt. Motor/Blower-Whether the motor/blower is not functioning, gently touch it to see if it is warm to the touch. If the motor is chilly, it should be replaced or repaired. Remove the porthole cover from within the aeration riser so that you can see the aeration process in action
  • The presence of turbulence and air bubbles in wastewater indicates that aeration is taking place. Replace all of the lids.

Removing the cover from the clarifier’s riser is the first step. It is necessary to install a riser if one does not already exist. The liquid under the surface should be clear, not hazy or grey. The buildup of floating particles should be skimmed off and disposed if there is an accumulation. It is recommended that a compartment be pumped if the scum layer is greater than 6 inches thick. Check to see that the baffle is still in place and has not degraded. Discharge Point– Make that the discharge point is working properly.

Even when the systems are running effectively, the discharge locations of aeration units are not suitable play areas for children to play.

Managing your Unit

Wastewater treatment plant pumpers are required to be registered with the Health District. The primary goal of tank pumping is to remove sludge from the tank. It is possible that you may need to be there during the pumping process to ensure that all sludge and wastewater is removed. Contract repairs must be carried out by licensed and certified specialists. Call the Health District at (513) 946-7966 if you would like to be included on a list of certified pumpers and contractors.

Questions

For further information, contact the Water Quality Division at 513.946.7966 or go to their website. This fact sheet is also available in a printable version by clicking here.

250 William Howard Taft Road2nd Floor, Cincinnati, OH 45219Phone 513.946.7800 Fax 513.946.7890hamiltoncountyhealth.org

Leave a Comment

Your email address will not be published. Required fields are marked *